Heavy Duty In-Wall VGA Cable
The BC-VVB003 Heavy Duty In-Wall VGA Cable family connects compatible VGA sources to projectors, monitors, and control-room displays while giving installers a choice of termination formats. Use a finished male-to-male assembly for an accessible route, or terminate after routing when a molded connector is too large for the opening.
Molded assemblies, field-terminable leads, bulk cable and screw-terminal HD15 connectors let you plan individual replacement runs or a multi-room installation from the same family. Our factory can review cable length, end configuration, run labels, and spare connectors together to help your installation team order a clearly specified assembly or kit.
- Analog VGA video connections for existing AV and equipment systems
- Finished assemblies and field-termination options
- 3+9 and 3+6 bulk cable choices with matching terminal connectors
- Custom length, labeling, and project packaging inquiries welcome
For concealed installation, specify the required cable rating with your inquiry. CL2, CL3, or plenum approval must be confirmed for the supplied construction.
Choose the Cable and Termination Method
A connector that works at the equipment may be too large for the route leading to it. This VGA family gives AV integrators and equipment buyers a choice between finished assemblies and cable they can terminate after routing. It is intended for analog video connections between compatible VGA equipment, not passive conversion from HDMI or DisplayPort.
Start with the termination method, then confirm the wiring, mechanical fit, and installation requirements. For a straightforward desk-side connection, our VGA-to-VGA cable may be a simpler option.
BC-VVB003 Configuration Guide
| Configuration | Order reference | Construction and supply | Selection check |
|---|---|---|---|
| Molded assembly | BC-VVB003-A | HD15 male to male; 3+9 construction; nominal 8.0 mm OD; dual ferrite housings; listed lengths 1–50 m | Confirm the target resolution at the chosen length and connector clearance. |
| Field-terminable assembly | BC-VVB003-B | One molded end and one screw-terminal HD15 end; 3+9 construction; nominal 8.5 mm OD; listed lengths 1–35 m | Approve termination instructions, route dimensions, and the required cable rating. |
| Bulk 3+9 cable | BC-VVB003-C12 | Three RGB coaxial elements plus nine auxiliary conductors; 150 m or 200 m reel options | Match the cable specification and pin map to the terminal connector. |
| Bulk 3+6 cable | BC-VVB003-C9 | Three RGB coaxial elements plus six auxiliary conductors; 150 m or 200 m reel options | Check which sync, ground, and display-identification connections are provided. |
| Field connector | BC-VVB003-D12 / BC-VVB003-D9 | HD15 male screw-terminal connectors for the corresponding 3+9 / 3+6 arrangement | Confirm cable entry, conductor size, terminal assignment, and strain relief. |
Reel length is a supply quantity, not a supported video distance. Listed assembly lengths do not guarantee 1080p at every length. Use the final conductor gauge, bulk-cable diameter, and materials from the approved drawing for the selected build.
Installation Rating Is a Separate Selection Requirement
Jacket appearance, PVC material, and a flame demonstration do not establish approval for a wall, riser, or air-handling space. Before ordering for concealed installation, specify the destination market and required cable designation, and obtain applicable marking and supporting documentation. The installer must assess the actual route against local requirements.
Molded VGA Assemblies
BC-VVB003-A is the finished male-to-male option, with molded connector housings, strain-relief boots, and ferrite housings at both ends. Choose it when the complete connector can pass through the planned route and both ports are accessible. Heavy construction is not a substitute for confirming bend space or the required environmental rating.

P/N: BC-VVB003-A
Molded HD15 male connectors at both ends provide a finished connection for compatible VGA ports. Select the required length and check the complete connector envelope before routing. For long runs, qualify the source, display, and target resolution together before bulk deployment.

P/N: BC-VVB003-A
Ferrite housings are positioned near the connector ends. Check their dimensions when planning a cable channel or a close-fitting equipment enclosure. They are a construction feature, not a guarantee that a complete installation will be free from interference.

P/N: BC-VVB003-A
The molded boot supports the transition from the connector housing to the cable. Leave enough space for a relaxed cable exit and support the run separately. Do not use the connector or its locking screws as a cable-pulling attachment.

P/N: BC-VVB003-A
Connect a compatible VGA source to a VGA display when retaining an existing analog installation. Confirm the display’s actual input; a large screen or familiar device shape does not indicate VGA compatibility. Audio requires a separate path.

P/N: BC-VVB003-A
Check a 1080p application for the selected length, equipment, and signal path. This picture is not a test report for every available length. Share the required timing and any wall plates, switches, or adapters when requesting a configuration.

P/N: BC-VVB003-A
Compare the connector body, ferrite housing, and cable exit with the available clearance. Use the approved drawing for the ordered version when planning an enclosure opening or purchasing a mating bracket. Image dimensions should not replace a production drawing.
Molded-to-Field-Terminal Assemblies
BC-VVB003-B combines a molded end with a screw-terminal end. Route the cable body before assembling the larger field connector, which helps when a pre-molded plug will not fit. Termination requires suitable tools and the approved wiring instructions; solder-free does not mean tool-free. Check the cable rating separately before concealed installation.

P/N: BC-VVB003-B.
One molded end and one field-terminable end let you route the cable body before assembling the larger connector. Confirm the conductor arrangement, terminal instructions, and strain-relief fit. Approval for concealed installation depends on the supplied cable specification, not this connector format.

P/N: BC-VVB003-B
The open housing shows screw terminals and the cable-entry arrangement. Use the approved terminal numbering and wiring diagram for your build; do not infer connections from wire colors alone. Close and secure the housing before connecting it to equipment.

P/N: BC-VVB003-B
The illustration compares terminal layouts, but it does not show that all VGA equipment uses every connection shown. Confirm RGB, sync, ground, and display-identification wiring against the intended application. Do not use this assembly as a general-purpose machine-control connector.

P/N: BC-VVB003-B
Plan cable preparation, termination, strain relief, and final checks as a controlled installation process. Follow the supplied instructions for conductor preparation and terminal tightening. The illustration does not replace the build-specific drawing or qualify an untested installation.
Bulk Cable and Construction References
Bulk cable lets installers allocate individual run lengths from one reel. Choose the 3+9 or 3+6 arrangement based on the required pin connections, not on the assumption that more conductors guarantee a longer video link. Confirm the exact gauge, jacket specification, and diameter before ordering. Reel quantities do not define the maximum distance between source and display.

P/N: BC-VVB003-C12
Bulk 3+9 construction provides three RGB coaxial elements and nine auxiliary conductors for a specified VGA wiring arrangement. Request the required reel quantity and drawing. The reel is cut into individual runs; its total length is not an end-to-end video rating.

P/N: BC-VVB003-C9
Bulk 3+6 construction is an alternative where its available connections match the application. Confirm the order reference, conductor gauge, finished diameter, and terminal compatibility before purchase. Do not select it solely by jacket appearance or assume identical wiring to the 3+9 version.

BC-VVB003 bulk-cable routing illustration. Cable diameter varies with construction; check the selected drawing before planning conduit fill or pulling clearance. Consider bends, bushings, and the installer’s handling requirements, as well as the straight opening. Do not pull on exposed signal conductors.

BC-VVB003 bulk-cable material view. The image shows the jacketed cable and material presentation. Ask for the exact jacket designation and relevant supporting documents when a project specifies flame performance. Appearance or material wording alone does not establish a building-code classification.

BC-VVB003 material demonstration reference. A pictured flame demonstration is not a standardized certification report and does not prove suitability for concealed or plenum installation. Use documented ratings for the supplied cable when preparing a project submittal; do not reproduce an informal flame test.
Screw-Terminal HD15 Connectors
The BC-VVB003-D12 and D9 connectors use screw terminals for field assembly without soldering. Match the connector to the cable construction and approved pin map, then check that the housing and strain relief accept the chosen cable. Keep a matching spare where future access or replacement is important; do not assume a different terminal layout is interchangeable.

P/N: BC-VVB003-D12
The 3+9 screw-terminal HD15 male connector supports field termination of a matched cable without soldering. Check the terminal map, cable entry, and conductor size range before selection. Suitable tools and build-specific instructions are still required for assembly and inspection.

P/N: BC-VVB003-D9
Select this 3+6 screw-terminal HD15 male connector for a cable with the corresponding approved wiring arrangement. Its terminal layout differs from the 3+9 option. Confirm strain relief and housing closure with your cable before committing to an installation kit.
Agree the Inspection Scope Before Production
A useful acceptance plan checks the delivered assembly against the drawing: connector gender, overall length, pin continuity, shorts, shield termination, and mechanical fit. For field-terminated runs, also inspect the completed cable clamp and enclosure before connecting equipment.
Request the inspection scope needed for your order. A continuity check alone does not demonstrate picture quality over a long route, and a flame demonstration is not a cable certification report.


Specify the Build for Your Installation
Tell us which ends should be factory finished and which must remain available for field termination. Custom-length requests should include the measurement reference, tolerance, service allowance, and connector orientation. Labels can identify rooms, racks, or cable ends so installers don’t have to trace every run again.
Include packaging, reel quantity, and spare-connector requirements in the same inquiry. Availability, minimum order, and lead time depend on the approved configuration.
Plan the Route, Not Just the Connector
This family can support legacy projector, workstation, and control-room display connections where VGA is still required. Plan the route around the actual connector envelope and cable diameter rather than the port alone. The illustrated conduit dimensions are configuration examples, not a guarantee that every version fits a particular conduit.
For concealed routes, obtain the required cable-rating documentation first. Outdoor, direct-burial, continuous-flex, and safety-critical applications require separate product qualification.

Yes. List each assembly configuration and the corresponding spare connector separately in your inquiry. Include quantities for the 3+9 and 3+6 versions so the quotation does not treat them as interchangeable. Confirm the approved pairing before ordering an installation kit.
Both constructions use three coaxial elements for the red, green, and blue video signals. The difference is the number of auxiliary conductors available for the remaining connections. Match the selected cable and terminal connector to the required pin map, including sync, grounds, and display-identification wiring. More conductors alone do not guarantee a sharper picture or a longer usable run.
Ask for a sample matching the intended construction and representative run length. Confirm the sample cost, availability, and delivery separately. Keep the approved sample and its drawing revision as the reference for the project order.
A long analog signal path can lose detail, while impedance discontinuities at cables, terminations, or adapters can produce reflections that appear as ghosting. First compare the display with a known-good short cable at the same resolution. Then check the installed termination and simplify the path by removing unnecessary adapters or wall-plate connections. If a correctly assembled passive run still falls short, consider an active transmission solution suited to the distance and equipment.
Send the original drawing or pin map, if available, connector photographs, overall length, and equipment models. Include any jacket markings needed for the installation. A matching connector shape or cable color alone is not enough to identify an equivalent replacement.
Plan a VGA Installation That Can Be Serviced Later
When an existing projector or control-room display still works, keeping its VGA connection can be more practical than replacing the whole system. The key choice isn’t just a heavier cable. It is a complete route you can install, check, and service without unnecessary disruption.
Start at the Equipment, Then Follow the Route
Record the source and display models, available VGA ports, and required resolution and refresh rate. Include wall plates, switches, splitters, and converters in the connection sketch. Each additional connection becomes part of the signal path. A passive VGA cable carries analog video; it cannot convert a digital-only output to VGA or carry the audio needed for a presentation system.
Measure the real route, including equipment access and service allowance. A straight-line room measurement can miss cabinet exits, corners, and the final approach to a projector. Check the connector and ferrite housing dimensions as well as cable diameter. A cable body that fits an opening does not mean a molded connector will pass through it.
Choose Where the Termination Happens
A fully molded assembly is straightforward when the route accepts its connector heads. A molded-to-field-terminable assembly is useful when you can finish one end after routing. Bulk cable is a different purchasing format: it allows multiple cut lengths but requires suitable termination and verification for each completed run.
For field work, agree on the terminal layout, conductor preparation, shield handling, and strain relief before installation. Do not substitute a generic color chart for the drawing supplied with the chosen cable. The 3+9 and 3+6 labels describe construction; they do not, by themselves, establish the full HD15 pin map or display-identification support.
Keep Building Requirements Separate from Video Performance
A good picture does not establish that a cable is suitable for a concealed route. Likewise, a required installation rating does not guarantee that a long analog connection will meet the image-quality target. Treat these as two separate acceptance requirements.
For a regulated installation, specify the required cable designation and request the corresponding documentation and markings for the actual supplied version. UL explains the role of cable classifications and markings in its Wire and Cable Guide. This reference explains selection principles; it is not evidence that this product holds a particular listing. Have the responsible installer assess the proposed route under the applicable local requirements.
Validate the Longest Intended Run
Before a multi-room order, evaluate a representative assembly at the longest planned length with the actual source and display. Use the intended resolution and refresh rate, and include the planned wall plates or switching equipment. Check fine text, color edges, stable synchronization, and display detection. A short demonstration cable cannot qualify a longer installed route.
If the result is poor, compare it with a known-good short connection and simplify the signal path. Ghosting, color changes, and an unstable picture can have different causes, including termination errors, signal loss, equipment settings, or interference. Do not assume that changing conductor count or adding ferrites will solve every symptom. If the passive path cannot meet the requirement, evaluate a suitable active transmission solution rather than relying on a universal distance claim.
Prepare a Practical Handover Record
Give each run an identifier and record the end locations, cable version, length, termination drawing, and test conditions. Where a field connector is used, inspect the housing closure and cable support as well as electrical continuity. Continuity results do not replace a functional video check, but they can help isolate wiring faults before connecting equipment.
Keep the approved sample and drawing revision available for repeat orders. If you need a replacement later, this record is more useful than a photo of a black cable. It also helps prevent someone from substituting a similar-looking connector or a different auxiliary wiring arrangement without review.
Send a Quote Request That Covers the Whole Installation
Include the assembly or reel quantity, termination format, required lengths, equipment models, target video timing, and any installation-rating requirement. Add labels, packaging, spare connectors, and the desired delivery date. If the route is constrained, a dimensioned sketch helps us review the connector envelope before we agree to the build.
You can compare other mechanical formats in our VGA cable range. For this family, use the inquiry button to send your configuration list so the quotation reflects the actual installation rather than a generic cable length.