x
Send Your Inquiry Today
Quick Quote
  • BC-VHA015-C100 cable with a protected HDMI mating head and an ordinary HDMI Type-A male plug
  • Waterproof HDMI Panel Mount Socket (Panel-Type Nut): Flush-mount socket secured with a rear nut.
  • Waterproof HDMI Panel Mount Socket (Flange-Type Screw): Socket with a flange, mounted with perimeter screws.
  • Exploded illustration of the protected HDMI connector and contact assembly
  • Protected HDMI cable heads and panel sockets in a housing construction illustration
  • Protected HDMI cable heads and panel sockets in an illustration labelled PBT engineering plastic
  • Illustrated mated HDMI panel connection with water droplets and an IP67 catalogue label
  • Connection Method: How to connect the cable to the panel mount socket or device.
  • Illustration of a protected HDMI cable head aligned with a matching panel socket and snap latch
  • Panel Installation Cut-Out Dimensions: Technical drawing for the required panel opening.
  • Panel Mount Installed Effect: Showing the socket neatly mounted in a panel or enclosure.
  • Illustration of a colour image displayed on a screen
  • Illustrated examples of protected HDMI panel connections on equipment enclosures
  • BC-VHA015-C100 cable with a protected HDMI mating head and an ordinary HDMI Type-A male plug
  • Waterproof HDMI Panel Mount Socket (Panel-Type Nut): Flush-mount socket secured with a rear nut.
  • Waterproof HDMI Panel Mount Socket (Flange-Type Screw): Socket with a flange, mounted with perimeter screws.
  • Exploded illustration of the protected HDMI connector and contact assembly
  • Protected HDMI cable heads and panel sockets in a housing construction illustration
  • Protected HDMI cable heads and panel sockets in an illustration labelled PBT engineering plastic
  • Illustrated mated HDMI panel connection with water droplets and an IP67 catalogue label
  • Connection Method: How to connect the cable to the panel mount socket or device.
  • Illustration of a protected HDMI cable head aligned with a matching panel socket and snap latch
  • Panel Installation Cut-Out Dimensions: Technical drawing for the required panel opening.
  • Panel Mount Installed Effect: Showing the socket neatly mounted in a panel or enclosure.
  • Illustration of a colour image displayed on a screen
  • Illustrated examples of protected HDMI panel connections on equipment enclosures
P/N: BC-VHA015

Waterproof HDMI Cable

Bring digital video and audio through a serviceable enclosure connection with the BC-VHA015 Waterproof HDMI Cable and matching panel sockets. The coordinated cable head, panel interface, and internal HDMI route help equipment builders provide an accessible AV connection while planning protection at the exposed mating point.

  • BC-VHA015 cable and panel sockets provide a coordinated HDMI connection for equipment enclosures.
  • Choose a panel-nut socket or a flange-screw socket to suit the mounting design.
  • The pictured 1 m cable has a protected mating head on one end and a standard HDMI Type-A male plug on the other.
  • IP67 is the catalog ingress-protection rating; confirm the specified mated or capped configuration and panel installation.
  • Snap fastening supports convenient connection to the matching socket.
  • Discuss the required 4K format, full cable route, materials, and environmental qualification before sample approval.

Plan the Cable, Mating Socket and Panel Seal Together

A serviceable AV enclosure needs a clear connection point and a reliable seal. The BC-VHA015 range combines a cable-mounted, protected HDMI head with nut-mounted or flange-mounted panel sockets. It gives equipment builders a practical way to plan the external connection, panel interface, and internal HDMI lead together.

The pictured C100 cable is listed at 1 m. The other end is a standard HDMI Type-A male plug, so that end still needs a protected location. Select the complete mating arrangement and mounting detail before treating the connection as a sealed system.

ComponentCatalogue referenceSelection detail
Cable assemblyBC-VHA015-C100Protected mating head to ordinary HDMI Type-A male; 1 m listed length
Panel-nut socketBC-VHA015-CRNut-retained panel housing with tethered cap shown; confirm cut-out, thread, gasket, and rear access
Flange-screw socketBC-VHA015-CSFlange housing with fixing holes and tethered cap shown; confirm hole pattern, fasteners, and gasket seating
Ingress protectionIP67 catalog ratingConfirm applicable test evidence and the exact mated/capped and installed state; not a blanket rating for open ports or the complete enclosure
Contact and housing constructionGold-plated contacts and zinc-alloy/PBT components describedConfirm the selected assembly bill of materials, finish, and seal material for the intended exposure
AV requirement4K applicationsSpecify refresh rate, color format, HDR, and audio/control functions; confirm performance through the complete cable/socket chain
Custom supplyOEM configuration inquiryDiscuss cable length, component quantities, labels, packaging, and qualification requirements

Send your enclosure drawing, source/display details, and environmental requirements. We can help identify the component combination to review before you commit to a panel design or production order.

Cable and Panel Socket Options

Choose the C100 cable with the CR panel-nut or CS flange-screw socket according to your enclosure layout. Check the cap, gasket, mounting hardware, and mating head to ensure they form a complete configuration. Confirm which components are included in the quotation.

BC-VHA015-C100 cable with a protected HDMI mating head and an ordinary HDMI Type-A male plug
Waterproof HDMI Cable

P/N: BC-VHA015-C100

The listed 1 m lead pairs a protected mating head with an ordinary HDMI Type-A male plug. Use the protected end with the matching panel socket and keep the ordinary end in a suitable enclosure. Confirm the required AV mode and working route.

Waterproof HDMI Panel Mount Socket (Panel-Type Nut): Flush-mount socket secured with a rear nut.
Waterproof HDMI Panel Mount Socket (Panel-Nut)

P/N: BC-VHA015-CR

The panel-nut version offers a compact mounting arrangement with a tethered cap. Check rear access for the nut, the panel opening, the sealing surface, and internal connector clearance. Specify the approved gasket and mounting detail before releasing the enclosure drawing.

Waterproof HDMI Panel Mount Socket (Flange-Type Screw): Socket with a flange, mounted with perimeter screws.
Waterproof HDMI Panel-Mount Flange Socket

P/N: BC-VHA015-CS

The flange-screw version provides separate fixing points around the socket. Match the flange footprint, hole pattern, panel thickness, and gasket arrangement to the enclosure. Allow space to operate the latch and cap and to connect the internal HDMI lead.

Keep the Contact Interface Clean

The contact illustration shows how the HDMI connection sits inside the protective housing. Keep mating surfaces clean and dry during assembly and service. Gold-plated contacts do not replace the surrounding seal or provide salt-spray resistance. For a corrosive environment, specify the relevant material and finish evidence with the sample request.

Exploded illustration of the protected HDMI connector and contact assembly
Protected HDMI cable heads and panel sockets in a housing construction illustration

Match the Housing to the Installation

The catalog describes zinc-alloy housing components. Assess the complete housing, finish, fixing method, and surrounding enclosure for the installation. A metal shell alone does not establish an impact, vibration, or corrosion rating. Give us the exposure and mounting conditions so the appropriate configuration can be reviewed.

Specify the Polymer and Seal Materials

The component illustration identifies PBT engineering plastic. Confirm the selected build’s polymer, seal, and cable-jacket materials when temperature, sunlight, cleaning agents, or oil exposure matters. Material grade and test conditions are more useful purchasing details than a general claim that the housing is suitable for every outdoor environment.

Protected HDMI cable heads and panel sockets in an illustration labelled PBT engineering plastic
Illustrated mated HDMI panel connection with water droplets and an IP67 catalogue label

Understand the IP67 Connection State

IP67 describes dust protection and temporary immersion under defined test conditions. For this assembly, confirm whether the rating applies when mated, capped, or otherwise installed as specified. An open socket and an ordinary HDMI plug do not automatically share that protection. Pressure washing, prolonged immersion, and chemical exposure need separate assessment.

Allow Access to the Snap Fastening

The snap fastening connects the protected cable head to its matching socket, giving service staff a defined mating interface. Leave room to align, engage, and deliberately release it after the panel is installed, including with neighboring cables in place.

Support the cable route so the latch is not carrying cable weight or repeated side loads. Follow the supplied mating instructions and include the installed support arrangement in any required vibration assessment.

Illustration of a protected HDMI cable head aligned with a matching panel socket and snap latch
Illustrated examples of protected HDMI panel connections on equipment enclosures

Design the Complete Enclosure Connection

Carry digital picture and forward audio through a defined panel connection for kiosks, equipment displays, and serviceable AV enclosures. An accessible socket lets you connect or replace the external lead without treating the entire internal cable route as one permanent assembly.

Choose the panel-nut or flange-screw socket around the enclosure drawing, then specify the source, display, complete cable length, and required 4K format. Keep the standard HDMI plug in a protected location, and confirm the IP67-rated connection status for the supplied components.

Does IP67 mean IP68 or protection against pressure washing?

No. IP67 covers dust protection and temporary immersion under defined conditions. IP68 and water-jet or high-pressure cleaning requirements are separate. State the actual exposure and request evidence for the selected connection state.

Are both ends of the pictured cable waterproof?

The C100 image shows a protected mating head on one end and a standard HDMI Type-A male plug on the other. Keep the ordinary end in a suitably protected location. If both ends must be exposed, discuss a different complete connection arrangement.

How do I choose the panel-nut or flange-screw socket?

Choose from the enclosure drawing and assembly access. Check the opening, gasket seat, panel thickness, rear clearance, and tool access for CR; check the flange footprint and fixing-hole arrangement for CS. Use the approved component drawing for final dimensions.

Can I use this assembly for a 4K display connection?

This range is intended for 4K applications, but specify the refresh rate, color format, HDR needs, and complete cable length when selecting it. The C100 cable, panel socket, internal lead, source, and display all form part of the connection. Check that complete path at the required settings before closing the enclosure. The IP67 rating concerns ingress protection; it does not establish video bandwidth or HDMI certification.

Can an ordinary HDMI plug provide the same external seal?

Physical and electrical fit do not establish environmental sealing. Use the specified matching protected mating head or approved cap and follow the installation requirements. Check rear-side access and protection separately.

Are salt-spray, UV and cleaning-fluid resistance included?

Those properties require their own material and qualification review. Specify the fluid, cleaning method, exposure duration, and temperature. The IP code alone does not prove resistance to corrosion, UV, or chemicals.

How should I protect the panel socket when the cable is disconnected?

Use the specified cap and follow the supplied closure instructions. Keep the mating area clean and dry, and inspect the cap and sealing surfaces before closing it. Confirm whether the stated protection applies to the capped socket as well as the mated connection; an open HDMI socket is not protected simply because its housing belongs to an IP67-rated assembly. Keep the rear connection protected inside the enclosure too.

What should I send for an OEM quotation?

Send the cable/socket references, panel drawing, required length, environment, source/display details, and AV format. Include sample and production quantities, accessories, labels, and packaging requirements. Lead time and commercial terms are confirmed for the quoted configuration.

Planning a Waterproof HDMI Connection at an Equipment Enclosure

A protected connector is most useful when it fits the way an enclosure is built and serviced. A kiosk may need an external connection that staff can disconnect without opening the cabinet. An equipment panel may need a replaceable HDMI interface rather than a cable permanently passed through a gland. Start with that service requirement, then define the environmental and video requirements for the complete connection.

Draw the Connection from the Exposed Side to the Equipment

The BC-VHA015-C100 cable shown here has a protected mating head on one end and a standard HDMI Type-A male plug on the other. That difference matters: the protected head does not make the ordinary plug or its connected device waterproof. Identify where each end will sit and which enclosure or other protection covers it.

The CR and CS panel sockets provide two mounting approaches. Confirm the front mating interface and rear termination of the chosen socket, then include the internal HDMI lead in the drawing. If the project needs two exposed cable ends, describe that requirement explicitly rather than assuming the pictured assembly provides a sealed head at both ends.

Choose the Mounting Method Before Cutting the Panel

The CR version uses a panel-nut arrangement; the CS version uses a flange with separate fixing holes. Neither choice can be made from panel thickness alone. Consider access for assembly tools, the available sealing land, clearance behind the panel, and the space needed to operate the front latch and tethered cap.

Obtain the selected component drawing before making the opening. Confirm the cut-out, any anti-rotation feature, fixing-hole pattern, permissible panel thickness, gasket position, and fastener requirements. Reference images help explain the layout, but the approved drawing should govern manufacturing. Burrs, uneven surfaces, or an unsuitable gasket seat can undermine an otherwise suitable connector installation.

State the Required Protection and Connection State

The catalog lists IP67 for this family. In the IP system, the digits describe protection against solids and water under specified conditions. Temporary immersion, water jets, and high-pressure cleaning have different requirements; you cannot substitute one for another. Phoenix Contact’s explanation of IP ratings illustrates why connector products may carry more than one water-protection rating.

For an order, ask which configuration was assessed: the fully mated connection, the socket with a specified cap, or another defined state. Also identify the panel installation used. A component rating does not automatically rate the entire enclosure, and an unplugged interface may need separate protection. Agree the applicable evidence before relying on the assembly in a demanding environment.

Describe the Exposure Beyond the IP Code

Rain, cleaning fluids, salt spray, sunlight, oil, and continuous immersion are not interchangeable conditions. Explain the actual environment, including cleaning method, fluid, temperature, and exposure duration where relevant. The materials and test requirements can then be reviewed against the intended service.

The catalog describes metal and engineering-plastic housing components, but material names alone do not establish chemical resistance, UV life, or a temperature limit. Specify the housing finish, seal material, and cable jacket in the selected build. For marine or wash-down projects, include the required corrosion or cleaning qualification rather than treating a general waterproof label as sufficient.

Protect the Mechanical Connection During Service

The illustrated snap fastening is intended to engage with the matching socket. Align the components and follow the supplied assembly instructions; do not apply a generic threaded-coupling procedure to the latch. Allow access for release after installation, including when neighboring cables are connected.

Support the cable so weight, snagging, or movement is not transferred directly to the mating interface. Agree bend-radius and strain-relief requirements for the selected lead. A pull-test illustration is not a working-load instruction, and the connector should not be used as a lifting or anchoring point. If vibration is part of normal operation, include the mounting arrangement and cable support in the qualification test.

Specify the Video Format Through the Whole Path

For a 4K project, specify the required refresh rate, color format, color depth, HDR requirement, and resolution. Add any required audio, ARC/eARC, or control function. Include the source, display, internal lead, panel socket, and any intermediate equipment in the assessment.

A sealed housing does not increase signal-path bandwidth. The official HDMI cable-category guidance explains the distinction between cable categories and certification programs. Do not infer certification from a connector photograph or a displayed picture. Review the selected configuration and test the actual required modes before enclosure closure or batch release.

Compare the Architecture, Not Just the Connector Price

If the connection is inside a dry enclosure, a conventional HDMI panel-mount coupler may address access requirements without a protected external mating system. If mechanical retention is the main requirement, compare locking HDMI cable options against the equipment fixing pattern. Neither alternative should be assumed to provide the same environmental protection.

A separate enclosure can also be appropriate where several connections need protection together. Compare service access, space, cable routing, and the complete environmental specification. Choose the arrangement that meets those requirements and allows for repeatable assembly.

Send a Configuration Brief for Sampling and Quotation

InformationWhat to include
Component selectionC100 cable, CR or CS socket, quantities, and required accessories
Mechanical drawingPanel geometry, thickness, sealing surface, rear clearance, and service access
EnvironmentRequired protection state, water exposure, cleaning, temperature, and any corrosion or vibration criteria
AV pathSource/display models, all leads and interfaces, and required video/audio/control modes
Supply scopeCable length, identification, packaging, sample quantity and production forecast

Send this brief to BespokeCable for a configuration review and quotation. A useful sample approval record includes the selected drawing, materials, accessories, and acceptance checks so the eventual production order refers to the same assembly you evaluated.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top