DVI-I Cable
The BC-VDC003 DVI-I Cable connects compatible equipment through the integrated DVI interface, with separate contacts for digital video and analog RGB. It helps you retain existing DVI-I monitors and equipment connections when replacing a worn lead or building an accessory kit. The cable carries the signal from the equipment; it does not convert analog video to digital.
Choose straight-to-straight, right-angle-to-straight or right-angle-to-right-angle plugs to suit the space behind both ports. Standard lengths from 0.6 to 15m cover short enclosure connections and longer routed installations. Our factory can review custom lengths, exit orientations, and identification so the assembly fits your equipment and is easy to reorder.
- DVI-I male-to-male cable with 24+5 contact arrangement
- S, SR, and RR connector layouts
- 0.6 / 0.8 / 1 / 1.5 / 2 / 3 / 5 / 8 / 10 / 15m
- Thumbscrew fastening for seated connections
- Shielded construction for the video signal path
- Standard supply and custom OEM assembly inquiries
DVI-I Assemblies for Equipment Replacement and OEM Builds
BC-VDC003 is a DVI-I male-to-male cable family for projects that need the integrated DVI connector format rather than a digital-only DVI-D plug. It is a practical starting point for replacing an installed cable, specifying an equipment accessory, or routing a connection behind an enclosure where the cable exit direction matters.
DVI-I supports digital and analog signals, but the connector name doesn’t tell you which signals your equipment supplies. Match the source, display, and cable wiring to the intended signal path. This cable is not an analog-to-digital converter. If your port has no provision for the four contacts around the flat blade, review our DVI-D cable options instead of forcing a DVI-I plug into place.
You do not need a finished drawing to start an inquiry. Send the existing cable reference or clear photos of both ports, the required length, and your expected quantity. We can review the standard configuration or discuss a custom DVI-I cable before you commit to a production specification.
BC-VDC003 Specifications
| Item | Specification |
|---|---|
| Series | BC-VDC003 |
| Connector type | DVI-I male at both ends; 24+5 contact arrangement |
| Straight configuration | BC-VDC003-S: straight to straight |
| Mixed-angle configuration | BC-VDC003-SR: right-angle to straight |
| Dual-angle configuration | BC-VDC003-RR: right-angle to right-angle |
| Standard lengths | 0.6 / 0.8 / 1 / 1.5 / 2 / 3 / 5 / 8 / 10 / 15m |
| Retention | Thumbscrew fasteners |
| Appearance | Black cable jacket and connector housings |
| Shielding reference | Three-layer shielding construction shown in the supplied cable illustration |
| Video requirement | Agree on the signal type, link wiring, resolution, refresh rate, and length for the ordered assembly |
| Custom requirements | Length, connector orientation, identification, and packaging reviewed for the project |
Choose Your DVI-I Connector Configuration
Three male-to-male configurations cover different cable-exit requirements. Choose the layout that suits each end of your equipment connection, then specify the length and quantity.

P/N: BC-VDC003-S
Two straight plugs suit connections with clear access behind both ports. This is the starting configuration for an open equipment rack or a straightforward replacement. Select a cable length that fits the installed route, leaving space for cable exits and screw access.

P/N: BC-VDC003-SR
Use a one-side-angle plug when the cable must run close to a panel but needs a straight connection at the other end. This mixed layout is useful when only one port has restricted clearance. Identify the angled end and its exit direction when requesting a quote.

P/N: BC-VDC003-RR
Two right-angle plugs guide the cable close to the equipment at both ends, making this layout useful where rear covers or brackets restrict a straight exit. Send the orientation of both installed ports with your inquiry so we can review a route that fits the complete assembly.
Match the DVI-I Contact Layout to Your Equipment
The BC-VDC003 plugs use the 24+5 DVI-I arrangement, including the contacts around the flat blade. That physical detail separates this family from digital-only DVI-D cables and is worth checking before ordering a replacement. A clear photo of each mating socket lets you identify the fit without relying on a generic “DVI” label.
Use the equipment specification to establish the signal requirement. Connector fit and signal support are separate checks, and you shouldn’t infer one from the other.


Turn the Cable Where Space Is Limited
A side-angle connector can guide the cable along a panel instead of sending it straight into a rear cover or nearby obstruction. Choose the SR version when one end needs that change in direction, or RR when both ends have restricted exits.
The installation illustration shows the routing principle, not a universal clearance measurement. Share a photo of the surrounding panel and the direction you need the cable to travel so we can review the connector orientation.
Specify the Shielded Construction You Need
The supplied cutaway shows a three-layer shielding arrangement with foil and braided elements beneath the jacket. For an equipment build, consider shielding alongside the cable route and connector termination, especially where other cables or electrical equipment share the enclosure.
If your project has a defined construction or grounding requirement, include it in the inquiry. Material grade, braid coverage, and electrical performance should follow the agreed specification, not assumptions based on a cutaway image.


Give Each End Its Own Installation Reference
The right-angle-to-right-angle model serves connections where both cable exits need to turn near the equipment. Its two connector ends still need separate orientation checks: the same housing can point in an unhelpful direction when the equipment ports are mounted differently.
Mark the source end and display end on a simple sketch or photograph. This gives a custom assembly discussion a clear starting point and helps prevent a physically similar but incorrectly oriented replacement.
Yes. List BC-VDC003-S, BC-VDC003-SR, and BC-VDC003-RR as separate lines with the length and quantity for each. Include any packaging differences so the quotation can distinguish the assemblies without relying on a single total quantity.
No. DVI-I provides separate contacts for analog and digital video, but a passive cable doesn’t convert one signal type to the other. The source must supply the signal type the display accepts. If one end is analog-only and the other digital-only, select an active converter for that direction instead of relying on the DVI-I connector shape.
Not always. Start with photographs of both connector faces, the equipment model, the length, and any markings on the old cable. If those details don’t establish the wiring or mechanical fit, we can discuss whether we need a sample or drawing.
Treat this as a video connection, and plan a separate audio path for any sound your installation needs. Do not assume that the audio behavior described for a particular graphics card or HDMI adapter applies to this DVI-I cable assembly.
Send the ordered model and length, source and display references, the selected resolution and refresh rate, and details of any adapter or switch in the path. Say whether the original cable still works in the same setup. Those details help distinguish a fit, signal-path, or configuration problem before specifying a replacement.
How to Specify a DVI-I Cable for an Existing Equipment Connection
A cable replacement is easiest when the new assembly preserves what already works. For BC-VDC003, start with the equipment connection and the installation space, then turn those observations into a repeatable ordering reference. This is more useful than selecting a cable only because the plug looks familiar.
Start at Both Ports, Not Just the Cable Label
Take a front-facing photograph of each socket and record the source and display model. A DVI-I plug has additional contacts around its flat blade that a DVI-D-only socket does not accept. Even when the plug fits, the equipment manual still determines whether that port provides a digital signal, an analog signal, or supports both. A passive cable carries the available signal; it does not generate the other type.
For a digital connection, match single-link or dual-link operation to the equipment requirement. For an analog connection, identify the relevant signal path explicitly. If adapters, switches, or a KVM are part of the installation, include them in the inquiry so the complete route can be reviewed.
Describe the Bend from a Defined View
Right-angle descriptions can be misleading when two people view a connector from opposite ends. Use the mating face, the flat-blade position, and a marked cable-exit arrow to describe the direction you need. For the RR model, record both ends separately. Two angled plugs are helpful only when each one clears the surrounding ports and follows the intended route.
A photograph with the panel edge and adjacent sockets visible is often more useful than an isolated close-up of the connector. Include access for the fastening screws and enough room for the cable to leave the housing without being forced into another sharp bend.
Order Length Against the Installed Route
Measure along the actual cable route, including service access and the path around brackets. Then agree how the finished cable length will be measured. A nominal end-to-end measurement and a jacket-only measurement are not interchangeable, particularly on a short angled assembly.
The ten standard lengths make it easier to choose a lead for a compact assembly or a longer equipment route. Include your resolution, refresh rate, and equipment references so that the ordered configuration addresses the complete connection. For longer routes or installations that already have signal problems, evaluate the selected cable in the full setup before committing to a repeat order.
Make Sample Approval Useful for Repeat Orders
Check more than whether an image appears once. On your representative equipment, check startup, display detection after reconnecting, and operation at the required video mode. Confirm the connector bodies fit, the screws stay accessible, and the cable doesn’t pull against the sockets. These checks are part of the intended installation; they are not a substitute for an agreed cable inspection specification.
Keep the approved model, length, connector-view references, and any custom requirements together under an identifiable revision. If you are replacing several existing cables, separate them by configuration instead of grouping everything under “DVI cable.” That makes quotation, receiving inspection, and later replenishment easier to manage.
Adapt the Assembly to Your Equipment Program
Our factory can review the S, SR, and RR layouts, including custom length, connector orientation, and customer identification. If several enclosures use different exits, list the variants in one inquiry with separate quantities. You can then compare options without losing the part-number detail installers need.
For repeat supply, bring the accepted sample reference and any label or packing requirements into the order specification. This turns a one-off replacement into a clearer procurement reference and helps your team distinguish visually similar assemblies when they arrive.
Not sure whether this is the correct interface?
Please send a photo of the port and browse our DVI cable range. We can help narrow the assembly requirements before we agree on the final drawing and order details.










