x
Send Your Inquiry Today
Quick Quote
  • BC-PAB005-2 DC splitter with one female barrel input and two male outputs
  • BC-PAB005-3 DC splitter with one female barrel input and three male outputs
  • BC-PAB005-4 four-way DC barrel splitter with moulded branch junction
  • BC-PAB005-5 DC power splitter with one female input and five male plugs
  • BC-PAB005-8 DC splitter with one female input and eight male output leads
  • Illustration of one adapter connected through a four-way DC splitter to four cameras
  • Diagram labelling 5.5 by 2.1mm female and male DC barrel connectors with centre-positive polarity
  • Four-way DC splitter dimension drawing showing approximately 41cm overall length
  • Close-up showing the moulded strain relief and a bent DC splitter lead
  • BC-PAB005-2 DC splitter with one female barrel input and two male outputs
  • BC-PAB005-3 DC splitter with one female barrel input and three male outputs
  • BC-PAB005-4 four-way DC barrel splitter with moulded branch junction
  • BC-PAB005-5 DC power splitter with one female input and five male plugs
  • BC-PAB005-8 DC splitter with one female input and eight male output leads
  • Illustration of one adapter connected through a four-way DC splitter to four cameras
  • Diagram labelling 5.5 by 2.1mm female and male DC barrel connectors with centre-positive polarity
  • Four-way DC splitter dimension drawing showing approximately 41cm overall length
  • Close-up showing the moulded strain relief and a bent DC splitter lead
P/N: BC-PAB005

DC Power Splitter Cable

Power a group of compatible low-voltage devices from one supply with a DC Power Splitter Cable. BC-PAB005 offers two to eight outputs for CCTV clusters, LED installations, and equipment panels, reducing separate adapter leads and keeping the distribution point close to the devices. Select the branch count and reach around your layout, with a shared source rated for the combined load.

  • One female DC input supplies 2, 3, 4, 5, or 8 male outputs.
  • 5.5 × 2.1mm barrel connections; confirm insertion length and polarity with your equipment.
  • Choose a compact Y lead or a multi-branch harness for nearby low-voltage devices.
  • Specify the shared input current, individual branch loads, and installed route for your build.
  • We can provide custom lengths, branch layouts, and wire specifications for project review.

Select the Splitter for Your Equipment Layout

When several devices share one cabinet or display, a separate adapter for each unit can make the installation unnecessarily crowded. The BC-PAB005 family distributes one compatible DC supply to two, three, four, five, or eight outputs, keeping the connection point close to your equipment.

These are passive parallel splitters, not power supplies or voltage converters. All connected devices must accept the same supply voltage and polarity. The common input carries the combined load, so connector fit alone isn’t enough to approve an installation. Send us the adapter label and device requirements, and we can help define the harness for a quote.

Selection pointBC-PAB005 configuration
InputOne 5.5 × 2.1mm female DC barrel socket
Outputs2, 3, 4, 5, or 8 male DC barrel plugs
ConnectionPassive parallel distribution from one source; no voltage conversion
PolarityCenter-positive arrangement shown in the connector illustration; confirm the ordered wiring map
LengthFour-way illustration shows approximately 41cm end-to-end; confirm dimensions separately for each ordered model
Color and constructionBlack molded connectors with flexible insulated leads; specify conductor and jacket requirements for custom orders
Electrical limitsConfirm assembly voltage, common-input current, and per-branch current before ordering
Project optionsBranch count, unequal branch lengths, connector size, wire specification, and identification labels

Compare the Five DC Splitter Configurations

Choose the branch circuit count for your device layout. Confirm the input and output ratings for the combined load; more plugs don’t mean more available power.

BC-PAB005-2 DC splitter with one female barrel input and two male outputs
1 Female to 2 Male DC Power Splitter Cable

P/N: BC-PAB005-2

A compact two-output Y-lead for two nearby devices sharing a single compatible DC supply. Confirm both loads together, not just the rating of each device.

BC-PAB005-3 DC splitter with one female barrel input and three male outputs
1 Female to 3 Male DC Power Splitter Cable

P/N: BC-PAB005-3

Three male output plugs connect three compatible devices to one female input. Share the branch destinations and required reach when specifying a cabinet or display harness.

BC-PAB005-4 four-way DC barrel splitter with moulded branch junction
1 Female to 4 Male DC Power Splitter Cable

P/N: BC-PAB005-4

Four outputs suit a grouped equipment layout. The illustrated four-way version measures approximately 41cm overall; confirm usable branch reach and the combined load for your order.

BC-PAB005-5 DC power splitter with one female input and five male plugs
1 Female to 5 Male DC Power Splitter Cable

P/N: BC-PAB005-5

Five output leads connect a small equipment cluster to a single input connection. Identify the devices and their startup demand so the shared feed can be specified appropriately.

BC-PAB005-8 DC splitter with one female input and eight male output leads
1 Female to 8 Male DC Power Splitter Cable

P/N: BC-PAB005-8

Eight outputs provide more connection points, not a higher power rating. Review the common-input capacity, cable routing, and fault-protection requirements before selecting this configuration.

Support the Cable at the Connection

Molded strain-relief sections help guide the lead away from the barrel connection. Leave a relaxed bend and secure the harness nearby rather than letting the weight of several branches pull on the input socket. For a moving mechanism, specify the movement and cycle requirement separately; a flexible-looking lead is not a verified continuous-flex cable.

Close-up showing the moulded strain relief and a bent DC splitter lead
Illustration of one adapter connected through a four-way DC splitter to four cameras

One Supply, Several Compatible Devices

One shared supply can make a CCTV cluster, retail display, or low-voltage equipment panel easier to wire and service. A splitter brings several power connections together, helping installers identify the common feed and route individual leads to nearby devices without a separate adapter at every position.

Use it with loads that share the same supply voltage and polarity. Tell us where each device sits and how much current it draws; we can review branch reach and identification for a practical equipment kit. The harness distributes power from one source and does not convert voltage or combine separate adapters.

Set the Branch Reach Before Ordering

The four-way dimension drawing shows an assembly of approximately 41cm. That is not the same as 41cm of free cable on every branch. Mark the source position, split point, and each device inlet on a sketch. We can review equal or unequal branch lengths so the harness follows the installation instead of leaving excess cable behind it.

Four-way DC splitter dimension drawing showing approximately 41cm overall length
BC-PAB005-8 DC splitter with one female input and eight male output leads

Choose the Branch Count Around the Layout

Two outputs may be enough for a paired device set; five or eight can reduce the number of separate adapter leads in a compact installation. Start with the actual loads and their locations, then select the branch count. If you need independent output fuses or fault isolation, include that requirement in the inquiry rather than assuming a passive splitter provides it.

Check the Barrel Size and Polarity

The connector illustration identifies 5.5 × 2.1mm and a center-positive arrangement. Also check the mating contact depth: a plug that appears to fit may still make unreliable contact. With power disconnected, connect the source adapter’s male plug to the splitter’s female input; connect the splitter’s male outputs to the devices’ female inlets.

Diagram labelling 5.5 by 2.1mm female and male DC barrel connectors with centre-positive polarity
Can I use a 5.5 × 2.5mm device with this splitter?

Do not assume compatibility because the outer diameter matches. The center contact differs from 2.1mm, and a loose or unsuitable fit can cause intermittent power. Confirm the device inlet dimensions or request the correct connector configuration.

Can some outputs remain unused?

Yes, as long as the connected loads remain within the approved supply and assembly limits. Keep unused male plugs insulated from conductive surfaces and secure them so they cannot be damaged during servicing.

Does a four-way splitter divide the available current equally?

No. Each device draws the current it needs from the common supply; the cable does not allocate one quarter of the available current to each output. Add the current required by all devices that may run together, allow for their startup demand, and check the shared input and each branch against their assembly limits. All devices must also accept the same source voltage and polarity. An adapter with a higher current rating cannot increase the splitter’s current rating.

Are the outputs individually fused?

These standard splitters do not include independent branch fuses. If each device needs separate fault protection, specify that requirement so that a suitable harness or distribution arrangement can be reviewed.

Can it power PoE cameras?

Not through an Ethernet port. This is a DC barrel-power splitter, not a PoE injector or Ethernet switch. Only consider it for cameras with a compatible separate DC inlet and the correct electrical requirements.

Is the standard splitter suitable for outdoor installation?

No weatherproof rating is established here. Keep the connections in an appropriately protected environment, or request an assembly whose connectors, seals, and installation conditions meet your outdoor application.

Can the branches have different lengths or connector types?

Yes, we can review those requirements for a custom build. Provide a branch-by-branch drawing with connector dimensions, polarity, and load information so the finished harness is defined unambiguously.

What should I send for a bulk quotation?

Send the BC-PAB005 model or desired branch count, source and device specifications, required lengths, quantity, and any labeling or documentation requirements. Include photos or drawings of the mating connectors if their identity is uncertain.

Planning a Shared DC Supply Without Guesswork

A splitter often tidies an installation, but the real purchasing question is more specific: can this one supply and harness support these particular devices together? A short load list and a route sketch are usually more valuable than choosing by output count alone.

Make a load list before choosing the adapter

Record the voltage, polarity, running current, and startup demand of each device. Add the loads that can operate simultaneously. For example, four devices drawing 0.5A each represent 2A of combined running demand at their common operating voltage, before allowing for startup behavior and the equipment maker’s design guidance. This example is a calculation, not a rating for the BC-PAB005.

The power supply must meet that demand, and the shared input connector and conductor must also be suitable. A larger adapter does not increase the safe current of a smaller cable. Also check branch loads individually, especially when one device uses much more power than the others.

Understand what parallel distribution does

Each output receives the same nominal source voltage; the connected load draws the current. The cable does not divide available amperage equally between outlets, regulate each branch, or turn a 12V source into 24V. Do not use its branches to join the outputs of separate adapters. Combining supplies requires equipment designed for that purpose.

Review voltage at the equipment, not only at the adapter

Every conductor and contact adds resistance. The common section carries the combined current, while each branch carries its own load. If a device resets during startup or an LED load becomes dimmer, inspect the supply, connector fit, routing, and voltage at the device under operating conditions. Increasing the adapter voltage without checking the device rating is not an appropriate shortcut.

For a longer single-device route, compare the DC power extension cable. Where one source must feed several destinations, specify the splitter and extension sections together so their combined resistance is considered.

Install the harness as a complete assembly

  1. Disconnect the power source and verify voltage, polarity, and connector dimensions against the equipment documentation.
  2. Connect the adapter’s male barrel plug to the splitter’s female input socket.
  3. Connect the male output plugs to the compatible device inlets. Protect unused plugs against contact with metalwork.
  4. Support the split point and route the leads clear of sharp edges, hot surfaces and service access.
  5. Check the complete installation under its expected simultaneous load before deployment.

A branch fault may affect other devices on the same supply. If continued operation or separate protection matters, review a protected distribution arrangement rather than relying on an unprotected fan-out lead.

Turn a sample into a repeatable purchasing specification

For OEM and bulk orders, agree the connector dimensions, polarity map, input and branch wire specifications, length measurement points, split position, and labels. Define the required inspection and electrical acceptance criteria with the quotation. If your project needs a material declaration or a specific approval, request documentation for the exact construction; a generic cable description is not evidence of certification.

Send BespokeCable your model choice, adapter details, device load list, route sketch, quantity, and delivery requirement. We can review a standard BC-PAB005 configuration or a custom branch layout. For other connector arrangements, explore our DC power cable range and tell us which connection needs to change.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top