DC Power Extension Cable
A DC power extension cable gives a compatible adapter more reach, so cameras, routers, LED equipment, and controllers can sit where the installation needs them. BC-PAB002 combines a 5.5 × 2.1 mm barrel connection with straight or right-angle exits, helping keep the cable route practical and the adapter accessible for service. Choose a complete male-to-female extension or an open-end lead for your equipment harness.
- 5.5 × 2.1 mm barrel connector options
- Male-to-female extensions and open-end pigtails
- Straight and right-angle plug layouts
- Length and wire size matched to your load
- Custom packaging for OEM and distributor orders
- Start your inquiry with a connector photo
BC-PAB002 Configurations and Ordering Specifications
An adapter can be electrically suitable but still leave the lead too short for the planned installation. BespokeCable supplies 5.5 × 2.1 mm DC power extension cables for compatible low-voltage installations, with straight or right-angle plugs and open-end options for equipment assembly.
The BC-PAB002 series offers two different connection methods. S and R models extend an existing barrel-plug lead through a female socket. PS and PR models end in two exposed conductors for a separately specified termination. Share a photo of the adapter and equipment socket, your approximate route length, and order quantity; we can use these to develop a configuration-specific quotation.
| Item | Specification or ordering choice |
|---|---|
| Series | BC-PAB002 |
| Nominal barrel size | 5.5 mm outer diameter × 2.1 mm inner opening; insertion length also needs to match the mating socket |
| Complete extensions | BC-PAB002-S: straight male to female; BC-PAB002-R: right-angle male to female |
| Open-end assemblies | BC-PAB002-PS: straight male to two wire ends; BC-PAB002-PR: right-angle male to two wire ends |
| Listed length choices | 3, 6, 10, 16.4, 20 and 33 ft; custom finished length by quotation |
| Listed wire-size choices | 24, 22, 20, 18 and 16 AWG; suitability depends on the complete assembly and load |
| Jacket and color | PVC; black or white options subject to configuration |
| Voltage, current and polarity | Specify the source and equipment requirements; the approved assembly specification defines the rating and wiring |
| Function | Passive DC connection; no voltage conversion or regulation |
Choose an Extension or an Open-End Lead
Keep the existing adapter plug with an S or R extension, or specify a PS or PR pigtail for an enclosed equipment connection.

P/N: BC-PAB002-S
A straight 5.5 × 2.1 mm male-to-female extension for an accessible cable route. The female socket receives the existing adapter plug, while the straight male plug connects to the equipment.

P/N: BC-PAB002-R
Use the right-angle male plug where a straight cable exit would project into a limited space. The other end remains a female barrel socket. Check the plug body against nearby ports and the enclosure.

P/N: BC-PAB002-PS
A straight male barrel plug with two open wire ends for integration into an equipment harness or a suitable terminal connection. Specify conductor mapping, stripped length, and the required end preparation before production.

P/N: BC-PAB002-PR
Combine a right-angle male plug with open wire ends when you need to address both the device-side exit and the internal termination. This is an assembly lead, not a ready-to-use female-socket extension.
Choose the Cable Construction Around the Load
A correctly sized conductor carries DC power from the adapter to the load while limiting voltage loss along the route. That matters when a camera is mounted away from its supply or a controller sits inside an enclosure: the equipment needs adequate voltage during operation and at start-up.
We can review the listed wire-size options against your finished length, normal current, and start-up demand. Specify the complete cable and connector assembly together, then confirm the voltage at the equipment under load. This gives an OEM kit a defined power connection, rather than a cable chosen by jacket thickness alone.


Match Both Sides of the Barrel Connection
The size illustration identifies the nominal 5.5 × 2.1 mm interface. It does not make every visually similar plug interchangeable: a 2.5 mm inner opening is a different size, and insertion depth and housing clearance also matter.
A close-up photo of the existing plug and socket is a helpful starting point. For repeat production, use a drawing or a mating sample to establish the connection you want to reproduce.
Give a Right-Angle Plug Room to Work
A right-angle exit can simplify the route behind a display, controller, or enclosure. It still needs enough space for the molded body and a relaxed cable bend. Position the lead so its weight doesn’t pull sideways on the equipment socket.
For a built-in installation, show us the port location and nearby features. That context is more useful than choosing an angled plug solely because it appears shorter in a catalog photo.


Build a Repeatable Equipment Kit
For an OEM build or installer kit, define the cable alongside the adapter and device rather than ordering it as an isolated accessory. Length, connector layout, and a clear pack label help your assembly team select the intended lead.
The application illustration shows possible equipment categories, not verified compatibility with every camera, router, or solar system. Send your actual equipment reference and quantities for a focused quotation. We also offer other connection formats in our DC power cable range.
The pictured standard barrel connection is not an established waterproof system. For exposure to rain, condensation, or washdown, specify the environment and ask for an appropriately rated cable-and-connector solution; placing a camera outdoors does not give its power lead an IP rating.
Each added connector introduces another contact interface, and each added cable increases the path resistance. Prefer one suitable finished length where practical. If multiple sections are necessary, assess the complete connection under the intended load rather than approving each section in isolation.
Check both the outer diameter and the center opening: this series uses 5.5 × 2.1 mm, not 5.5 × 2.5 mm. The insertion length and space around the socket matter too. Compare the equipment specification or an existing mating plug, then confirm voltage, polarity, and load current separately. If the size is unclear, send a close-up photo and measurements so we can help identify the connection.
The standard models shown use ordinary barrel connections, not a specified latch or screw lock. Do not force the plug; wait for it to click. If positive retention is required, request a locking connection for the mating equipment.
This page covers cable assemblies. List any adapter, terminal, or other accessory you need in the inquiry so the quotation can state exactly what is included.
Send the length and quantity breakdown for each model. We can review it as a mixed-configuration inquiry and quote the packing arrangement needed to keep the versions identifiable.
They depend on the selected construction and customization. Tell us whether you need an evaluation sample, a pilot order, or repeat bulk supply; the quotation will confirm availability, minimum quantity, and timing.
First, compare the operation with and without the extension. If the problem appears only with the longer lead, check the connectors and measure the voltage at the device while it starts and runs. Cable resistance can cause a larger voltage drop as current rises. A shorter lead or a larger conductor may help, but also check the supply capacity and connector ratings. Send us the route length and equipment current so we can review a suitable assembly.
Planning a DC Extension Without Creating a Power Problem
A successful extension begins with the complete route: adapter lead, added cable, connectors, and equipment input. Buying the longest available lead can create unnecessary slack and resistance; choosing the shortest possible lead can put mechanical tension on the socket. Start with the installed route and allow a practical service loop.
Set a voltage-drop budget
Current travels through both conductors, so the electrical path includes the outgoing and return wire as well as the contacts. The basic relationship is voltage drop = current × total path resistance. Longer wire and additional connections increase that resistance. No single AWG recommendation suits every distance and load.
For an initial review, provide the adapter output, equipment operating range, expected current, and added cable length. Then evaluate the selected assembly with the intended load, including start-up or other demanding operating conditions. A thicker conductor may reduce wire resistance, but it does not increase a connector’s own rating.
Separate extension wiring from power conversion
This passive cable does not make an unsuitable adapter suitable. The supply must already provide the voltage and polarity required by the equipment. A matching barrel size is only a mechanical starting point; it cannot establish current capacity or electrical compatibility.
For a male-to-female extension, agree on the center-contact and outer-contact continuity mapping. For open-end leads, document which conductor reaches each plug contact. Wire color is an identification aid, not a substitute for checking the agreed mapping before connecting equipment.
Plan open-end terminations as part of the assembly
PS and PR models require a suitable insulated connection at the wire end. The termination method, conductor preparation and strain relief must suit the receiving terminal and enclosure. Do not leave exposed conductors accessible in service. Qualified assembly personnel should make and inspect this connection with the power disconnected.
If you need a complete plug-to-plug lead instead, our DC male-to-male cable models serve a different connection arrangement; they are not substitutes for a female-socket extension.
Approve the installed sample, not just its appearance
Check plug engagement without forcing the connection, clearance around the right-angle body, cable support, and access for servicing. Electrical acceptance should cover polarity, continuity, voltage at the load, and temperature under the defined operating conditions. Specify the checks and acceptance limits required for your order rather than assuming a generic test claim covers your installation.
Once you accept the sample, retain the configuration, drawing revision, and packaging reference for reorders. If your requirements are still taking shape, send photos of the equipment first. We can clarify the missing details before you commit to the production specification.










