x
Send Your Inquiry Today
Quick Quote
  • BC-DAI005-A SFF-8654 4i SlimSAS cable with four numbered SATA data connectors
  • BC-DAI005-B SFF-8654 4i to SFF-8087 internal storage cable
  • BC-DAI005-C SlimSAS 4i cable with one SFF-8639 U.2 end and separate SATA-style power input
  • BC-DAI005-D SFF-8654 4i to SFF-8643 Mini-SAS HD cable
  • BC-DAI005-E SlimSAS 8i cable with eight numbered straight SATA data ends
  • BC-DAI005-F SlimSAS 8i cable with two SFF-8087 branches
  • BC-DAI005-G SlimSAS 8i cable with two U.2 drive ends and separate power inputs
  • BC-DAI005-H SlimSAS 8i cable with two SFF-8643 Mini-SAS HD branches
  • BC-DAI005-I SlimSAS cable with four SFF-8482 SAS drive connectors
  • BC-DAI005-J SlimSAS cable with one external SFF-8644 connector
  • BC-DAI005-K SlimSAS cable with two external SFF-8644 branches
  • BC-DAI005-L direct SFF-8654 SlimSAS cable with release tabs
  • BC-DAI005-M SlimSAS cable with four SFF-8482 drive connectors and four separate peripheral-style power inputs
  • BC-DAI005-N cable assembly with two U.2 drive connectors and separate power inputs
  • BC-DAI005-O internal cable assembly with two Mini-SAS HD branches
  • BC-DAI005-P SlimSAS breakout cable with eight numbered angled SATA data ends
  • BC-DAI005-A SFF-8654 4i SlimSAS cable with four numbered SATA data connectors
  • BC-DAI005-B SFF-8654 4i to SFF-8087 internal storage cable
  • BC-DAI005-C SlimSAS 4i cable with one SFF-8639 U.2 end and separate SATA-style power input
  • BC-DAI005-D SFF-8654 4i to SFF-8643 Mini-SAS HD cable
  • BC-DAI005-E SlimSAS 8i cable with eight numbered straight SATA data ends
  • BC-DAI005-F SlimSAS 8i cable with two SFF-8087 branches
  • BC-DAI005-G SlimSAS 8i cable with two U.2 drive ends and separate power inputs
  • BC-DAI005-H SlimSAS 8i cable with two SFF-8643 Mini-SAS HD branches
  • BC-DAI005-I SlimSAS cable with four SFF-8482 SAS drive connectors
  • BC-DAI005-J SlimSAS cable with one external SFF-8644 connector
  • BC-DAI005-K SlimSAS cable with two external SFF-8644 branches
  • BC-DAI005-L direct SFF-8654 SlimSAS cable with release tabs
  • BC-DAI005-M SlimSAS cable with four SFF-8482 drive connectors and four separate peripheral-style power inputs
  • BC-DAI005-N cable assembly with two U.2 drive connectors and separate power inputs
  • BC-DAI005-O internal cable assembly with two Mini-SAS HD branches
  • BC-DAI005-P SlimSAS breakout cable with eight numbered angled SATA data ends
P/N: BC-DAI005

SFF-8654 SlimSAS Cables for Server and Storage Integration

  • Connect SlimSAS controller ports to SATA drives, SAS backplanes, or U.2 routes with the matching host signals.
  • Choose 4i and 8i layouts, including numbered straight or angled SATA branches.
  • Plan one or two U.2 connections with separate power inputs.
  • Specify trunk length, branch reach, connector exits, and bay labels for your chassis.
  • Compare fourteen model configurations for different drive and backplane routes.
  • Request model availability, sample terms, and quantity pricing with your equipment details.

Product Details

Connect server controllers to drive bays and backplanes with BC-DAI005 SFF-8654 SlimSAS assemblies. Choose 4i or 8i layouts for numbered SATA branches, SAS drive connections, U.2 routes, or matched storage links. Select the layout for your host signals, then define branch lengths and power inputs around the chassis.

For an accurate quote, send both equipment model numbers, port photos, and the installed route length. BespokeCable can review the cable configuration against your drawing so you can define the connector count, branch spacing, and power arrangement before you order.

SlimSAS Specifications and Ordering Information

ItemConfiguration
SeriesBC-DAI005; individual suffix identifies the layout
InterfaceSFF-8654 SlimSAS, 4i or 8i as specified
DestinationsSATA, SFF-8087, SFF-8639, SFF-8643, SFF-8482, SFF-8644 or SFF-8654
Listed lengths0.5m, 0.7m and 1m; confirm availability for the selected model
Electrical useSAS, SATA or PCIe only where the host, destination and cable pin map agree
PerformanceTarget protocol, generation, length and channel acceptance criteria agreed for the selected assembly
Drive powerSeparate from the high-speed data path; power inputs vary by harness
Build detailsConfirm conductor size, shielding, jacket, retention and environmental requirements in the order specification

Choose the Route Before the Cable Length

ConnectionStarting point
Four SATA drivesA: 4i to four SATA data ends; compatible host channels and forward wiring required
Eight SATA drivesE or P: 8i to eight straight or angled SATA data ends
Mini SAS backplaneB/F for SFF-8087; D/H for SFF-8643; confirm lane grouping and sideband signals
U.2 NVMe driveC or G: one or two SFF-8639 ends, with the required PCIe host mapping and power inputs
Four SAS drivesI or M: four SFF-8482 ends; M includes separate peripheral-style power inputs
External Mini SAS HDJ or K: one or two SFF-8644 ends; check enclosure support and chassis exit protection
Direct SlimSAS linkL: match both port widths, keying, signals, and retention

This guide identifies cable families, not guaranteed equipment compatibility. An eight-lane connection is not automatically eight NVMe drives, and a passive branch does not create additional controller lanes.

SAS, SATA and NVMe Need Different Host Signals

SFF-8654 describes an interconnect form factor. A board may assign its port to SAS/SATA storage, PCIe/NVMe, or a controller-specific combination. Changing the connector at the other end does not convert one protocol into another. A SATA-only host cannot run a SAS drive through this harness.

For an SFF-8639 U.2 NVMe connection, confirm PCIe lanes, reference-clock arrangement, reset, and other required sideband signals. Two-drive branches also need a host topology that supports the intended independent links. Do not substitute a U.2 cable into a U.3 or tri-mode design without checking that controller’s cable and backplane requirements.

Specify the Channel, Not a Headline Rate

SlimSAS products exist for different SAS and PCIe generations, but a connector family’s capability is not a qualification report for every cable assembly. Provide the operating rate, installed length, and endpoint details for the selected build. A SATA branch remains subject to the SATA link’s own limit; an older backplane is not upgraded by a new SlimSAS plug.

If your equipment uses internal Mini SAS HD SFF-8643 or MCIO, compare the matching connector and signal assignments. Browse the SAS cable collection for other endpoint combinations.

Custom SlimSAS Assemblies for Repeat Builds

Define connector orientation, trunk length, individual branch lengths, labels, and the power-input layout in one controlled drawing. Tell us whether the route passes under a lid, across a fan zone, or alongside a removable drive cage. These details help distinguish a cable that fits on the bench from one that remains accessible in the finished chassis.

Request a sample, quantity pricing, lead time, and any required inspection or channel-test documentation with your inquiry. Acceptance tests and compliance documents should be agreed for the specific build, not inferred from a general product-family description.

Send your SlimSAS cable requirements for a quotation, including the controller model, drive or backplane, branch lengths, power inputs, and quantity.

SFF-8654 SlimSAS Cable Configurations

Select a BC-DAI005 layout by destination and branch count. The fourteen model cards cover direct links, SATA breakouts, SAS drive ends, and U.2 routes. Match host signals, lane grouping, and power inputs to the chosen assembly.

BC-DAI005-A SFF-8654 4i SlimSAS cable with four numbered SATA data connectors
SFF-8654 4i to Four SATA Data Ends

P/N: BC-DAI005-A

Four labeled SATA branches suit a compatible four-channel storage connection. Specify controller-to-drive forward wiring and the branch lengths needed to reach each bay. These are data connections; arrange drive power separately. A PCIe-only SlimSAS port will not operate SATA drives through a passive harness.

BC-DAI005-B SFF-8654 4i to SFF-8087 internal storage cable
SFF-8654 4i to SFF-8087 Cable

P/N: BC-DAI005-B

Link a SlimSAS port to a traditional internal Mini SAS connection when both endpoints support the required storage signals. Match the four-channel pin map and sideband requirements. This mixed-connector cable can preserve an existing backplane route; it does not change the backplane generation or controller protocol.

BC-DAI005-C SlimSAS 4i cable with one SFF-8639 U.2 end and separate SATA-style power input
SFF-8654 4i to U.2 with Separate Power Input

BC-DAI005-C

Connect one U.2 drive through a defined internal route, with a separate SATA-style power input. For an NVMe drive, the SlimSAS host port must supply the required PCIe signals. Send the drive model and power requirements so the connector pin map, supply rails, and cable lengths can be specified together.

BC-DAI005-D SFF-8654 4i to SFF-8643 Mini-SAS HD cable
SFF-8654 4i to SFF-8643 Cable

BC-DAI005-D

Bridge the physical gap between SlimSAS and Mini-SAS HD interfaces in a compatible internal storage system. Confirm the controller and backplane connections, lane order, and sideband requirements before choosing the assembly. Allow room for both latches and the cable bend; changing connector shape does not convert PCIe into SAS.

BC-DAI005-E SlimSAS 8i cable with eight numbered straight SATA data ends
SFF-8654 8i to Eight SATA Data Ends

BC-DAI005-E

Route eight SATA data branches from a compatible SlimSAS host connection to individual drive bays. Specify branch numbering and each installed length to keep drive identification straightforward. Drive power is separate, and the host-to-drive wiring direction must match the intended installation rather than being inferred from the connector ends.

BC-DAI005-F SlimSAS 8i cable with two SFF-8087 branches
SFF-8654 8i to Two SFF-8087 Ends

BC-DAI005-F

Divide an eight-lane physical connection into two four-lane connector groups for a compatible controller and backplane layout. When requesting a quotation, provide the port assignments, branch lengths, and sideband requirements. The passive harness preserves the specified wiring; it does not add a controller or upgrade the equipment’s supported link generation.

BC-DAI005-G SlimSAS 8i cable with two U.2 drive ends and separate power inputs
SFF-8654 8i to Two U.2 Drive Ends

BC-DAI005-G

Bring two U.2 drive connections and their separate SATA-style power inputs into one planned harness route. NVMe operation requires suitable PCIe lane allocation at the host, including bifurcation where the platform requires it. Identify both drive models, host configuration, and power connections before confirming the assembly drawing.

BC-DAI005-H SlimSAS 8i cable with two SFF-8643 Mini-SAS HD branches
SFF-8654 8i to Two SFF-8643 Ends

BC-DAI005-H

Use two Mini-SAS HD branches where the system routes separate channel groups from an eight-lane SlimSAS connection. Branch lengths can be specified around the actual backplane positions. Confirm the signal assignment and sideband wiring at each port; identical connector shells alone do not establish compatibility between SAS and PCIe equipment.

BC-DAI005-I SlimSAS cable with four SFF-8482 SAS drive connectors
SFF-8654 to Four SFF-8482 Drive Ends

BC-DAI005-I

Connect four SAS drive interfaces through a harness matched to the controller’s lane assignments. This model has four combined drive-end connectors, not a single drive connection. Specify the power path in the approved drawing and use a SAS-capable host for SAS drives; a SATA-only controller cannot operate them.

BC-DAI005-J SlimSAS cable with one external SFF-8644 connector
SFF-8654 to One External SFF-8644 End

BC-DAI005-J

Plan an internal-to-external storage route with a SlimSAS connection at one end and a metal SFF-8644 connector at the other. Match the controller and enclosure interfaces, then define the chassis exit and strain relief. The external connector format by itself does not provide an outdoor or waterproof rating.

BC-DAI005-K SlimSAS cable with two external SFF-8644 branches
SFF-8654 8i to Two External SFF-8644 Ends

BC-DAI005-K

Route two external Mini-SAS HD branches from a specified SlimSAS channel assignment. Provide the controller port details, enclosure connections, and required branch lengths so the wiring can be reviewed as a complete route. Two physical branches do not automatically create two independent links without the appropriate host configuration.

BC-DAI005-L direct SFF-8654 SlimSAS cable with release tabs
Direct SFF-8654 to SFF-8654 Cable

BC-DAI005-L

Keep a direct internal connection between compatible SlimSAS ports while routing the harness through the chassis. Confirm the connector width at both ends, signal assignment, latch orientation, and installed length. Leave access for release tabs and service removal, rather than selecting a cable solely by the distance between ports.

BC-DAI005-M SlimSAS cable with four SFF-8482 drive connectors and four separate peripheral-style power inputs
SFF-8654 to Four SAS Drive Ends with Power Inputs

BC-DAI005-M

Organize four SFF-8482 drive connections with four separate peripheral-style power inputs. This layout helps distinguish the data route from the power feeds during installation. Provide the drive startup load, power-connector pin map, and individual branch lengths; the connector appearance alone is not enough to approve the supply arrangement.

BC-DAI005-P SlimSAS breakout cable with eight numbered angled SATA data ends
SFF-8654 8i to Eight Angled SATA Ends

BC-DAI005-P

Use eight angled SATA data ends where straight connectors would interfere with a bay cover or nearby hardware. Confirm the bend direction from the mating view, then specify branch order and lengths. These are data connections with separate drive power, and the host must support the intended SATA wiring arrangement.

Four SAS Drive Ends, with Separate Power Inputs

BC-DAI005-M combines four SFF-8482 drive connections with four peripheral-style power inputs, keeping each drive supply feed accessible beside the data branch. Define the branch labels and lengths around the bay positions so installation and later drive identification follow the same map.

Send the controller model, drive startup requirements, PSU connection, and bay layout for a harness review. The approved drawing records the power pins, lead lengths, and permitted load alongside the data wiring, helping purchasing reorder the same configuration.

BC-DAI005-M SlimSAS cable with four SFF-8482 drive connectors and four separate peripheral-style power inputs
Can I leave some breakout branches unused?

Possibly, but check the controller and backplane configuration first. Leave unused connectors secured away from fans and conductive surfaces, without forcing tight bends. For an NVMe breakout, the required host-lane grouping still applies even if only one drive is installed. Tell us which bays will be populated when defining the harness.

Is a SATA breakout cable reversible?

Do not assume so. A forward breakout typically connects a multi-lane controller port to individual SATA drives; a reverse breakout serves a different host/backplane arrangement. Specify the equipment at both ends and their port labels. A cable with the same physical connectors may have the wrong wiring direction for your system.

Can I request a quotation without a complete cable drawing?

Yes. Start with the controller and drive or backplane models, clear connector photographs, the desired route, and an approximate quantity. Include an existing harness label if available. These details help narrow down the assembly before you finalize connector orientation, branch lengths, and the pin map.

Can a longer cable retain the same data rate?

Not automatically. The supported rate depends on the particular cable construction, length, connectors, and complete channel. State the required SAS or PCIe generation and installed length in your inquiry. Treat a different length as a configuration to qualify, rather than extending a performance claim from a shorter sample.

What should I check on a qualification sample?

Check fit, latch access, branch reach, and drive identification first. Then test the intended controller, firmware, backplane, and drives at the required link settings under a representative workload. Record link negotiation, errors, and any resets. Agree on the sample acceptance criteria and required evidence before ordering the production batch.

Will an eight-way SATA breakout connect SAS drives?

No: SATA data plugs do not provide the required SAS drive interface. A SAS drive needs an appropriate drive-end connector, a SAS-capable controller, and the correct power arrangement. If your drive list contains SAS models, identify them before selecting the breakout family.

Can branch labels match my drive-bay numbering?

Include the required label text and its position in your inquiry, such as the controller port, bay number, or your internal part number. For repeated builds, put that mapping in the approved drawing so a replacement harness can be identified without relying on cable color alone. Label format and production details should be confirmed in the quotation.

What quantity information is useful for an OEM quotation?

Provide the sample quantity, initial build quantity, and expected repeat demand for each configuration. Different connector combinations and branch constructions may have different purchasing requirements. Ask for the applicable minimum quantity and lead time for your exact assembly rather than relying on a single family-wide figure.

Can I order a replacement by matching a photograph?

A photograph is a useful starting point, but it cannot establish the internal wiring. Add the original part number, equipment models, and any available pinout or drawing. Pay particular attention to breakout direction, sideband signals, and power inputs. Match those details before treating a visually similar cable as a replacement.

How should I specify an angled SATA end?

Provide a photograph or drawing showing the connector in its mating position, with the required cable exit marked. Terms such as left-angle and right-angle can change depending on the viewing direction. Also show nearby covers or drive trays so the bend does not obstruct installation or service access.

What should be recorded for repeat orders?

Keep the approved drawing revision, connector combination, branch lengths, labels, power pin map, and acceptance criteria together with the ordered part number. If a component substitution is proposed, review its effect on fit and electrical requirements before accepting it. This is especially important when a chassis uses several similar SlimSAS variants.

What information helps investigate an unstable connection?

Record the cable part number and length, controller and drive models, firmware versions, negotiated link rate, and the observed errors. Include photographs of the installed route and power connections. If practical, compare with a known-good configuration; this helps separate a cable issue from host settings, power, or mechanical strain.

Planning a SlimSAS Cable Route That Can Be Built and Serviced

A server cable is often selected after the controller, drives, and chassis have already been chosen. That leaves a small but important integration problem: the right signals must reach the right bays, with enough room to assemble and service the system. SlimSAS projects are easier to quote when that route is described as a connection plan rather than a list of connector names.

Write Down What Each Port Actually Carries

Begin with the controller or motherboard manual. Record the SlimSAS port identifier and whether it is assigned to SAS/SATA, PCIe/NVMe, or a specific tri-mode configuration. A PCIe expansion slot on the controller card connects it to the computer; it does not mean every cable socket on that card carries PCIe to the drives.

Then identify the destination by its complete model number. A drive, a passive backplane, and an expander backplane are different destinations even when their cable sockets look familiar. For a backplane, include the port-to-bay diagram. This lets the branch labels correspond to real bay numbers instead of an arbitrary cable order.

Allocate Four- and Eight-Lane Routes Deliberately

Four SATA branches generally represent separate storage channels. An NVMe drive may instead use a group of PCIe lanes. The same count of conductors therefore does not imply the same number of drives. When routing an 8i connection to two U.2 destinations, check the host’s lane grouping and configuration requirements before assuming that both drives will enumerate.

Where a system offers several possible harnesses, choose the one that matches the documented port assignment with the fewest unnecessary intermediate connections. An additional adapter consumes space and becomes another point to identify during servicing. If an adapter is unavoidable, include it in the channel qualification and mechanical drawing rather than treating it as invisible.

Measure the Installed Path with the Lid and Trays in Mind

The shortest distance between two sockets is rarely the usable route. Measure along the intended cable path, allowing for connector bodies, a service loop, and the space needed to operate each release. Check whether the cable must cross a fan wall, pass through a cutout, or move with a removable assembly.

For breakouts, record the trunk length to the split and each branch length from the split to the destination. A uniform branch length may be convenient for purchasing but awkward when bays are staggered. Numbered ends should follow a consistent bay map so that a technician can replace one drive without tracing the whole bundle.

Keep the Power Drawing Beside the Data Drawing

The four-drive I and M layouts illustrate why power needs its own description. A combined drive connector has both data and power contacts, but the cable still needs to get the correct supply from somewhere. The M photo shows separate peripheral-style inputs; U.2 layouts C and G show SATA-style inputs. Neither connector style alone establishes the supply rails, wire capacity, or permissible combined startup load.

List the PSU connection, drive power requirements, and any power-disabling or auxiliary-signal considerations relevant to the chosen drives. Follow the equipment manufacturer’s installation instructions and isolate power before internal cable work unless the complete system is expressly designed for the intended hot-swap procedure.

Approve a Reference Assembly That Purchasing Can Reorder

Once the route is settled, use one drawing revision to capture endpoints, pinout, length tolerances, branch labels, and power inputs. Agree which inspections and system checks are required for sample approval. Continuity inspection answers a different question from reliable operation at the target signaling rate; neither should silently stand in for the other.

Keep the approved drawing and equipment configuration with the purchase record. If the controller, SSD, or backplane changes later, review the cable again rather than assuming the same connector family guarantees interchangeability. Send that information through the inquiry form so we can discuss the appropriate BC-DAI005 configuration, sample requirements, and production quantities.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top