x
Send Your Inquiry Today
Quick Quote
  • BC-DAI006-A SAS drive cable with a separate seven-pin data lead and drive-side power connection
  • BC-DAI006-B cable with a SAS drive receptacle and combined SATA-style data and power contacts
  • BC-DAI006-C straight adapter with a SAS drive receptacle and combined 22-pin contact interface
  • BC-DAI006-D angled SAS 29-pin to SATA-style 22-pin adapter
  • BC-DAI006-E SAS drive cable with a straight data plug and four-pin peripheral-style power input
  • BC-DAI006-F SAS drive cable with an angled data plug and four-pin peripheral-style power input
  • BC-DAI006-A SAS drive cable with a separate seven-pin data lead and drive-side power connection
  • BC-DAI006-B cable with a SAS drive receptacle and combined SATA-style data and power contacts
  • BC-DAI006-C straight adapter with a SAS drive receptacle and combined 22-pin contact interface
  • BC-DAI006-D angled SAS 29-pin to SATA-style 22-pin adapter
  • BC-DAI006-E SAS drive cable with a straight data plug and four-pin peripheral-style power input
  • BC-DAI006-F SAS drive cable with an angled data plug and four-pin peripheral-style power input
P/N: BC-DAI006

SAS to SATA Cables and Adapters for Compatible Storage Systems

  • Six SAS drive cable and adapter configurations.
  • Flexible leads or compact straight and angled adapters.
  • Separate or combined data-and-power arrangements.
  • Peripheral-power input on selected cable models.
  • Custom routing and identification for OEM builds.
  • Passive interconnects; SAS drives require a SAS controller.

Product Details

Fit a SAS drive connection into your existing storage cabling layout with the BC-DAI006 range of cable assemblies and compact adapters. Choose separate data and power connections, a combined 22-pin interface, or a peripheral-power lead to suit the space behind the drive. BespokeCable can review the mating arrangement and cable route for your OEM build.

These are passive interconnects, not SAS-to-SATA protocol converters. A SAS drive still requires a SAS-capable controller. A SATA-shaped connector on the cable does not make a standard SATA motherboard port compatible with a SAS disk. Send a drive-label photo and controller model if you are unsure which connection you need.

BC-DAI006 Configuration Overview

ItemSelection information
Product rangeSix pictured configurations, BC-DAI006-A through F
Drive-side interfaceSFF-8482-style 29-contact receptacle; confirm mating drawing
Other connections7-pin data, 15-pin power or combined 22-pin contacts, according to model
Power-lead optionsSeparate SATA-style power provision or 4-pin peripheral input on selected cable models
Mechanical optionsFlexible leads, compact straight adapter and 90-degree adapter
Cable lengthListed cable options include 0.5m and 0.7m; confirm model availability and required route
Link capabilityDepends on controller, drive, wiring, and complete channel; qualify the selected assembly at the required rate
Ordering detailsSpecify mating interfaces, orientation, power pin map, length, and quantity

Match the Controller Before Choosing the Connector

SAS and SATA share some physical connection conventions, but their host capabilities are not interchangeable. A suitable SAS controller may support SATA drives; a SATA-only controller cannot operate a SAS drive through a passive adapter. The controller manual and drive model determine which combinations are supported.

The 29-contact receptacle mates with the drive. Controllers with multi-lane Mini SAS or SlimSAS ports also need an upstream harness matched to their port and drive mapping. For that part of the route, compare our SFF-8087 cable assemblies or SFF-8643 Mini-SAS HD cables.

Choose a Flexible Lead or a Compact Adapter

A cable lead gives you room to separate the data route from the power feed. A rigid adapter reduces loose cabling but adds a fixed body behind the drive, so its depth and orientation matter. Angled options help redirect the connection when a straight exit would interfere with a cover or drive tray.

Models E and F include a four-pin peripheral-style power input. Models B, C, and D use a combined SATA-style contact arrangement on the other side. None generates or regulates drive power. The approved pin map must match the power supply and the drive, including any model-specific power-management requirements.

Specify a Build You Can Reorder

For custom cable assemblies, tell us the installed length, preferred exit direction, power-source connection, and labeling requirements. A photograph of the existing installation is a useful starting point; a complete engineering drawing is not required to begin the discussion. Before production, record the mating details and electrical requirements in the agreed specification.

Include the required inspection criteria, contact finish, cable flammability, environmental conditions, and compliance documents in the quotation request. These requirements become part of the specification for the selected build.

Request a SAS drive cable or adapter quotation with the drive model, controller, power connection, installed route, and quantity.

SAS Drive Cable and Adapter Configurations

Compare the six BC-DAI006 layouts based on their physical connections and power arrangements. Share your drive and controller details if you need help selecting a starting configuration.

BC-DAI006-A SAS drive cable with a separate seven-pin data lead and drive-side power connection
SAS 29-Pin Cable with Separate Data and Power Provision

P/N: BC-DAI006-A

A flexible data lead and drive-side power provision let you route the two connections separately. Choose this layout when the power feed must stay close to the drive while the data cable follows a different path. Match the host signals and power mating arrangement before ordering.

BC-DAI006-B cable with a SAS drive receptacle and combined SATA-style data and power contacts
SAS 29-Pin to SATA-Style 22-Pin Cable

P/N: BC-DAI006-B

A short, flexible assembly links the drive-mating receptacle to combined data-and-power contacts. It eases a rigid alignment problem that would strain the drive connector if a direct adapter were used. Define the overall route, mating connector, and power pin map for the intended storage system.

BC-DAI006-C straight adapter with a SAS drive receptacle and combined 22-pin contact interface
Straight SAS 29-Pin to 22-Pin Adapter

P/N: BC-DAI006-C

This compact straight adapter combines the data and power contact groups into a single rigid connection. It suits installations where the mating cable can align directly behind the drive. Include the adapter body and attached plug in your clearance check; it changes the physical interface, not the controller protocol.

BC-DAI006-D angled SAS 29-pin to SATA-style 22-pin adapter
90-Degree SAS 29-Pin to 22-Pin Adapter

P/N: BC-DAI006-D

The angled body redirects the combined connection where rear clearance is limited. Use the pictured mating orientation as a starting point and check nearby trays, covers, and fasteners. This model has combined data-and-power contacts; it is not simply a seven-pin data elbow.

BC-DAI006-E SAS drive cable with a straight data plug and four-pin peripheral-style power input
SAS Drive Cable with Straight Data End and LP4 Power

P/N: BC-DAI006-E

Separate the straight seven-pin data connection from a four-pin peripheral-style power input. The flexible branches help organize the host and PSU routes independently. Specify drive power requirements and the supply pin map, and use a SAS-capable data source when connecting a SAS drive.

BC-DAI006-F SAS drive cable with an angled data plug and four-pin peripheral-style power input
SAS Drive Cable with Angled Data End and LP4 Power

P/N: BC-DAI006-F

An angled data plug changes the cable exit, while the separate peripheral-style input provides the power connection. This arrangement is useful where a straight data plug would crowd adjacent hardware. Confirm the angle from the mating view and define both branch lengths for the installed route.

A Separate Power Branch for a Practical Drive Route

The BC-DAI006-E layout separates a straight seven-pin data plug from a four-pin peripheral-style power input. This lets you plan the data and PSU branches independently instead of forcing both along the same path.

Send the drive model and a photo of the available power lead when requesting this configuration. We can review branch lengths and mating details for your build. The supply rails, contact assignments, and startup load must match the drive; the harness does not convert voltage or add SAS support to a SATA-only host.

BC-DAI006-E SAS drive cable with a straight data plug and four-pin peripheral-style power input
Can you help identify an adapter from my existing cable?

Yes. Send clear photographs of both mating faces and the drive label, plus the controller model if available. Include any original part number. We can discuss the closest physical configuration; we still need to check the final wiring and equipment compatibility before a production order.

Will the adapter need its own driver?

A passive cable or adapter does not install a driver or add a storage controller. Your HBA or RAID controller may require its own supported firmware and operating-system driver. If a disk isn’t detected, check those requirements, along with the power and cable routing.

Will changing the cable make an unsupported disk format usable?

No. Connector adaptation does not change a drive’s logical sector format, firmware restrictions, or controller support. Check the exact disk model and format against the controller documentation. Any reformatting is a separate operation that can erase data and is not a function of this cable.

Can the rigid adapters be used in a removable drive tray?

Only if the complete tray arrangement supports their dimensions and mating alignment. The added body may change insertion depth or interfere with a backplane. Check the tray with the adapter installed before committing to a batch, and do not force a blind-mate connection.

What should be included in a sample request?

Identify the BC-DAI006 layout, mating equipment, required cable length where applicable and expected quantity. Tell us which checks the sample must pass, such as clearance, drive detection, or operation at a specified link rate. Confirm sample availability, pricing, and lead time for the requested configuration.

Can repeat orders use our own identification labels?

Include the requested label text, position, and packaging identification with your inquiry. For mixed builds, use a distinct reference for each connector orientation or power arrangement. Keep that reference tied to the approved drawing so that visually similar assemblies are not substituted during purchasing or installation.

Planning a SAS Drive Connection Without Rebuilding the Whole Harness

A short SAS drive cable or compact adapter can help reuse a compatible storage harness when the drive position or power route changes. Plan the controller-to-drive signal path, power feed, and connector support together. This keeps a small mechanical change from becoming a larger chassis rebuild.

Trace One Complete Drive Path

Start at the actual host controller, not the shape of the last cable plug. Record its model and the port used, then follow any breakout cable, backplane, or intermediate adapter to the drive. A seven-pin connection may be part of a SAS-capable harness, but the same shape can also be attached to a SATA-only motherboard. The photograph alone cannot distinguish between the two.

Check whether the application uses one data path or requires dual-port SAS operation. Do not assume that a 29-contact drive receptacle preserves both SAS ports through a seven-pin data branch. If redundant paths are required, request an explicit connection diagram and select a complete controller-to-drive arrangement designed for that purpose.

Reserve Space for the Adapter and Its Mating Cable

With a rigid adapter, measure the full assembled depth: drive connector, adapter body, and attached plug. Also check side clearance and the rear cover. An adapter that fits an open bench may obstruct a removable tray or put pressure on the connector when the chassis is closed.

With a flexible lead, allow enough length to route naturally without pulling on the drive. Secure the cable to the chassis where appropriate rather than letting its weight hang from the receptacle. For an angled connector, send the mating-view photograph with the desired cable exit marked; an unqualified left-or-right description can be interpreted from opposite viewpoints.

Review Power Independently of Data

A drive may remain undetected because its power arrangement is unsuitable, even when the data wiring is correct. Check the drive manual for required rails and startup current, and identify the actual PSU lead being used. Four-pin peripheral inputs do not provide every supply or control connection found on a SATA power interface.

Do not select or modify the power connection solely by wire color. For a custom harness, document the contact assignments and any required handling of power-disable or other drive-specific functions. Do not interchange modular PSU cables between power supplies unless the PSU manufacturer explicitly supports that combination.

Validate the Installation Before Repeating It

Install the sample with power isolated unless the complete equipment is expressly designed for the intended hot-swap procedure. Check connector seating, strain relief, and clearance before powering the system. Confirm that the controller identifies the expected drive and negotiates the intended link, then run a representative workload and review error or reset reports.

Keep the controller, firmware, drive model, and harness revision with the sample approval record. A later disk substitution can change power requirements or system support without changing the apparent connector shape. Reusing the same approval checklist makes that change visible before you assemble a batch of systems.

Send the Details That Make a Quotation Useful

Send your SAS drive connection requirements, including the drive label, controller model, existing cable ends, and a photograph showing the available space. Identify the closest BC-DAI006 model and include sample and production quantities. We can use those starting details to discuss a suitable physical configuration, then confirm the drawing and commercial terms for the build. For other connector families, see the SAS cable range.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top