  • BC-DAI008-S internal cable assembly with two straight SlimSAS 8i connectors.
  • BC-DAI008-R SlimSAS 8i cable with straight and side-exit connectors
  • BC-DAI008-S internal cable assembly with two straight SlimSAS 8i connectors.
  • BC-DAI008-R SlimSAS 8i cable with straight and side-exit connectors
P/N: BC-DAI008

SAS to SAS SlimSAS 8i Cables for Internal Storage Links

  • SlimSAS SFF-8654 8i-to-8i internal cable assemblies for compatible controller and backplane connections.
  • Straight and side-exit connector examples help plan routing around adjacent ports and chassis covers.
  • Specify both endpoint part numbers, signal assignment, cable length and exit direction before ordering.
  • SAS or PCIe operation depends on the complete hardware and cable configuration; connector fit alone does not establish compatibility.
  • Send a mating-face photo or drawing for a configuration review and quotation.

Product Details

Connect compatible controller, board, and backplane interfaces with BC-DAI008 SlimSAS SFF-8654 8i-to-8i cable assemblies. Straight and side-exit configurations let you plan a direct internal link around chassis covers, neighboring ports, and release access. Define the endpoint signals and exit directions together for your OEM build.

Start with the controller and backplane part numbers. We can then discuss the required connection, routing space and assembly drawing. This page covers the direct 8i-to-8i configuration; for other endpoint combinations, see our SFF-8654 cable range.

Configuration Reference

ItemSelection information
Product familyBC-DAI008 internal SlimSAS cable assemblies
Primary endpointsSlimSAS SFF-8654 8i at both ends; confirm mating connector part numbers
Straight exampleBC-DAI008-S, shown with straight connectors
Side-exit exampleBC-DAI008-R, shown with one straight and one side-exit connector
Orientation referenceThe BC-DAI008-L card is a connector-option illustration, not confirmation of an assembled cable configuration
Signal assignmentConfirm SAS or PCIe application, lane mapping and any sideband requirements against the endpoint documentation
LengthSpecify the measurement method and required route length on the assembly drawing
Mechanical requirementsConnector exit, latch access, adjacent-port spacing and cable routing envelope
Performance acceptanceAgree the required link generation and system-level acceptance conditions for the selected assembly

Choose the Exit Direction Before the Cable Length

A straight connector may suit an open route but leave too little room beneath a cover. A side-exit version can redirect the cable near the port, yet it may obstruct the next connector or put the release mechanism out of reach. The useful choice is the one that allows full engagement, an unstressed cable route and removal during service.

Please mark the required exit direction on a mating-face photo. Terms such as left, right and down change meaning when the connector is viewed from the cable side instead of the port side. A marked drawing is more reliable than a direction name alone.

Match the Electrical Link, Not Just the Connector

SFF-8654 identifies a connector interface used in different system designs. It does not make every assembly suitable for every SAS or PCIe application, and a passive cable does not translate one protocol into another. Controller support, backplane wiring, lane allocation and cable construction must agree.

Specify the target link generation, equipment models, cable length, and required validation evidence for the selected assembly. These details define the complete operating channel and its acceptance criteria.

Prepare a Useful Inquiry

Send the two endpoint part numbers, their connector drawings if available, a photo of the intended route, required length and quantity. Include the target protocol and any existing cable reference. If you are replacing a cable, note whether the problem is reach, orientation, latch access or link reliability; each calls for a different review.

For a new OEM installation, agree the sample configuration before setting the production reference. Mechanical fit and electrical operation should be checked in the intended equipment, not inferred from appearance. Send your connection details for a quote and we can help turn them into a defined assembly requirement.

SlimSAS Cable and Connector Options

Choose a straight or side-exit SlimSAS 8i assembly for a direct internal link. Use the connector-direction reference to mark the required exit, then record the connector pair, wiring, and length in the assembly drawing.

BC-DAI008-S internal cable assembly with two straight SlimSAS 8i connectors.
SFF-8654 8i to SFF-8654 8i Cable

BC-DAI008-S connects two compatible SlimSAS 8i interfaces with straight cable exits. It suits internal routes with space behind both ports. Define the endpoint wiring and installed length, then check the route with the cover and neighboring cables in place so both release mechanisms remain accessible.

BC-DAI008-R SlimSAS 8i cable with straight and side-exit connectors
Side-Exit SlimSAS 8i Cable

BC-DAI008-R pairs a straight SlimSAS 8i connector with a side-exit end to redirect the bundle near the port. Mark the exit on a mating-face view and check adjacent-port clearance. Specify cable support and release access for the finished enclosure before approving the sample.

SlimSAS 8i and 4i connector exit-direction illustration showing straight, right-exit, right-angle and left-exit options; selection reference only.
SlimSAS Connector Exit Reference

Reference BC-DAI008-L is a connector-orientation guide, not a verified assembled-cable specification. It illustrates both 4i and 8i options, which are not interchangeable. Mark the required 8i mating face and cable exit, then confirm the final assembly reference on the approved drawing.

Make Room for the Connector and the Technician

A side-exit assembly redirects the cable where space directly behind the port is limited. Plan its direction around the adjacent connectors and chassis cover so the cable clears nearby hardware while leaving the release mechanism accessible.

Send a photograph with both ports and the intended route marked for a connector-orientation review. Check the proposed layout with neighboring cables installed, then capture the connector views and restraint points in the approved drawing.

BC-DAI008-R SlimSAS 8i cable with straight and side-exit connectors
Can I replace an existing cable using its photograph alone?

A photo helps identify the connector style and exit direction, but it does not show the pin assignment or establish electrical performance. Provide the original cable reference and both endpoint part numbers; use a drawing or supplier documentation to confirm the replacement requirements.

Does an 8i cable provide eight independent drive connections?

Not by itself. This page concerns a direct 8i-to-8i connection, not a drive breakout. The usable endpoints depend on the controller, backplane and signal assignment. If you need individual drive connectors, specify that topology instead of assuming that this assembly supplies them.

Can I turn a right-angle plug over to reverse the cable exit?

Do not assume that you can. The mating geometry and retention arrangement determine how the plug engages. Specify the required cable exit from a labeled mating-face view and select the appropriate assembly rather than forcing or twisting the connector.

Is the connector-option illustration a list of orderable cable models?

No. The illustration compares connector forms and exit directions, including 4i and 8i examples. It is a selection reference, not evidence that every illustrated combination is supplied under BC-DAI008-L. Confirm the connector pair and final assembly reference before ordering.

What should I send if the existing link is unstable?

Provide the controller and backplane references, cable length and identification, operating mode, firmware details and a description of the observed errors. Include whether the issue changes with another known-working cable or port. An unstable link is not proof that a different connector angle or a higher advertised speed will solve it.

Checking Clearance for a Direct SlimSAS 8i Link

For a direct SlimSAS 8i-to-8i connection, usable clearance includes the cable route and the technician’s release path. Check the assembly with covers and neighboring cables installed so the approved layout can be assembled and serviced in the finished equipment.

1. Identify Both Ends Separately

Label the endpoints A and B on your drawing. Record the controller or board part number, the mating connector reference and the port function at each end. Two similar-looking ports on the same board may have different assignments. If a vendor specifies a cable or wiring arrangement, use that information as the starting point rather than substituting a visually similar assembly.

Keep connector identity separate from the interface protocol. A SlimSAS housing does not by itself establish SAS support, PCIe lane mapping or backplane compatibility. For a broader comparison of storage interconnects, our SAS cable collection provides other connector families to consider.

2. Draw the Route with the Cover Installed

Include the space above the connector, the first change of direction and any restraint points. Measure the intended cable path, not just the straight-line distance between ports. Allow a practical service route without creating a long loose loop that can reach a fan or interfere with a removable module.

A side-exit connector moves the bundle away from the plug in a different direction; it does not eliminate the cable’s bending requirement. The acceptable bend and support arrangement must come from the selected assembly, so do not assume that a short, tight turn is harmless because it fits inside the enclosure.

3. Check the Neighboring Ports

Test the layout with adjacent connectors populated. A configuration that fits an empty chassis may become inaccessible when the system is fully assembled. Look for interference between connector bodies, crossed bundles and cable ties that would need to be cut during a routine replacement.

The release mechanism also needs working space. The technician should be able to release the plug before withdrawing it, without pulling on the cable bundle or levering against the board. This matters especially when a right-angle exit places the bundle across the normal hand-access path.

4. Agree What the Sample Must Demonstrate

Separate mechanical acceptance from electrical acceptance. Mechanical checks cover engagement, retention, routing and access. Electrical checks should use the intended controller, backplane, firmware and required operating mode. Define the expected link behavior and workload before testing so that a successful connection is not mistaken for complete qualification.

If another component changes later, review whether the approved configuration still applies. A new backplane revision or a longer cable route can change the conditions that made the original sample acceptable.

5. Keep the Approved Configuration Reorderable

The final drawing should identify the two connector views, cable length convention, exit directions and agreed signal assignment. Attach the approved cable reference to the equipment bill of materials. This gives purchasing and assembly teams a shared definition, instead of relying on a photograph or the words “SAS to SAS.”

Send your direct SlimSAS link requirements with the endpoint information and a marked route photo to begin the review. If your requirement is a drive-side connection rather than an 8i board-to-board link, compare the SFF-8482 drive-interface options to identify the appropriate connector family.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top