x
Send Your Inquiry Today
Quick Quote
  • BC-DAI011-A OCuLink cable with Mini SAS HD SFF-8643 termination
  • BC-DAI011-B OCuLink cable with SlimSAS SFF-8654 4i termination
  • BC-DAI011-C OCuLink cable with one U.2 drive connector and a separate SATA-style power input
  • BC-DAI011-D OCuLink cable with two straight terminations
  • BC-DAI011-E OCuLink cable with straight and angled termination arrangements
  • BC-DAI011-A OCuLink cable with Mini SAS HD SFF-8643 termination
  • BC-DAI011-B OCuLink cable with SlimSAS SFF-8654 4i termination
  • BC-DAI011-C OCuLink cable with one U.2 drive connector and a separate SATA-style power input
  • BC-DAI011-D OCuLink cable with two straight terminations
  • BC-DAI011-E OCuLink cable with straight and angled termination arrangements
P/N: BC-DAI011

OCuLink Cable Assemblies for Defined PCIe Connections

  • Choose from five BC-DAI011 OCuLink cable configurations.
  • OCuLink-to-OCuLink, Mini SAS HD, SlimSAS, and U.2 connection options.
  • U.2 version includes a separate SATA-style power-input branch.
  • Straight and angled terminations for different routing requirements.
  • Match host PCIe signals and endpoint wiring before selecting the assembly.
  • Specify mating parts, pinout, length, and target PCIe channel for quotation.

Product Details

Build a defined PCIe route between your host and endpoint with BC-DAI011 OCuLink cable assemblies. Choose a direct link, Mini SAS HD or SlimSAS termination, or a U.2 drive connection with separate power input. Match the mating interfaces and signal map, then set the length and cable exit around your equipment.

Choose from five pictured configurations, including direct OCuLink links and assemblies with Mini SAS HD, SlimSAS, or U.2 terminations. These are passive cable arrangements, not protocol converters. A familiar connector housing does not make a SAS-only port communicate with a PCIe device.

Specification and Ordering Scope

ItemSelection detail
SeriesBC-DAI011-A through E; reference photographs identify the connector layouts.
OCuLink interfaceFour-lane reference configurations. Confirm the mating part, orientation, signal assignment, and required sidebands.
Alternative endsA: Mini SAS HD SFF-8643. B: SlimSAS SFF-8654 4i. C: U.2 SFF-8639 plus a separate power-input branch.
Direct connectionD: straight OCuLink terminations. E: straight and angled OCuLink terminations; confirm plug/socket arrangement from the drawing.
ConstructionPassive copper cable assemblies. No integrated protocol bridge, PCIe switch, or retimer is established for these reference models.
PerformanceSpecify required PCIe generation and lane width. Qualify the ordered length and complete channel; connector type alone is not a speed rating.
PowerC needs a suitable external power source for the U.2 drive. Do not assume an OCuLink data lead powers an SSD or GPU.
Length and materialsDefine installed route, conductor and shielding requirements, branch reach, labeling and acceptance evidence in the quotation.

Which Configuration Should You Start With?

ConnectionReference and checks
OCuLink to Mini SAS HDA; both boards must expose compatible signals through an agreed pin map. Not a SAS-to-PCIe bridge.
OCuLink to SlimSASB; confirm SFF-8654 4i mating interface, protocol, and lane assignment.
One U.2 NVMe SSDC; confirm the PCIe host, SFF-8639 wiring, and drive power source.
Matching OCuLink portsD; check both equipment specifications, connector implementation, and installed length.
Angled OCuLink routeE; approve the exact mating faces, plug/socket arrangement, and available clearance.

For an MCIO connection, compare the MCIO reference assemblies rather than substituting a cable by appearance. Browse other endpoint combinations in the storage interconnect collection.

Request an OCuLink cable quotation with board documentation, the BC-DAI011 suffix, installed length, and quantity. Include the target PCIe generation and power details for a U.2 connection.

OCuLink Cable Configurations

Five real reference assemblies for different mating interfaces and routes. Confirm both ports, the pin map, and the required channel performance before selecting a model.

BC-DAI011-A OCuLink cable with Mini SAS HD SFF-8643 termination
OCuLink to Mini SAS HD Cable

P/N: BC-DAI011-A

Link an OCuLink connection to a Mini SAS HD SFF-8643 interface with a cable matched to both boards. Specify the pin map, sidebands, and installed route so the assembly carries the intended signals. Both endpoints must support that protocol; this passive cable does not convert a SAS-only port into PCIe.

BC-DAI011-B OCuLink cable with SlimSAS SFF-8654 4i termination
OCuLink to SlimSAS 4i Cable

P/N: BC-DAI011-B

An SFF-8654 4i-style termination provides a different board connection than Mini SAS HD. Match the source and endpoint documentation before choosing this assembly. Confirm lane assignment, sidebands, and orientation; the SlimSAS name alone does not establish SAS, SATA, or PCIe operation.

BC-DAI011-C OCuLink cable with one U.2 drive connector and a separate SATA-style power input
OCuLink to U.2 with Power Input

P/N: BC-DAI011-C

Connect one compatible U.2 NVMe drive through an agreed PCIe lane map, with a separate SATA-style power input shown in the reference photo. Verify the source rails, pinout, and SSD power requirements. The power branch accepts a supply; it does not generate power from OCuLink.

BC-DAI011-D OCuLink cable with two straight terminations
Straight OCuLink Cable

P/N: BC-DAI011-D

Connect matching OCuLink interfaces through straight terminations where the route has room behind both ports. Define the connector implementation, installed length, and target PCIe generation together. Check cable support and release access in the finished equipment, and validate the complete host-to-endpoint channel for the selected assembly.

BC-DAI011-E OCuLink cable with straight and angled termination arrangements
OCuLink Straight-to-Angled Cable

P/N: BC-DAI011-E

The angled termination offers a different mating and cable-exit arrangement from the straight reference. Approve the plug/socket combination and latch access against your actual port. An additional mating interface can affect the channel, so do not assume the same performance as a shorter direct connection.

U.2 Data and Drive Power Need Separate Checks

Model C combines an OCuLink data path, one U.2 drive connector, and a separate SATA-style power input. Plan the SSD location and supply branch together so the drive connection can be installed without pulling either route.

Send the drive model, host pin map, power-source details, and required branch lengths for review. The harness drawing records the populated rails and contact assignments against the SSD requirements; a 15-contact housing alone does not establish the supply arrangement.

BC-DAI011-C OCuLink cable with one U.2 drive connector and a separate SATA-style power input
Is an OCuLink cable a USB or Thunderbolt converter?

No. These passive assemblies route defined signals between compatible interfaces. They do not add a USB controller, Thunderbolt controller, or protocol bridge. Select the cable based on the actual host and endpoint connection.

What does four-lane OCuLink mean?

It describes a four-lane link arrangement, not four total differential pairs. Each PCIe lane has separate transmit and receive paths. Confirm the full lane and sideband map against the equipment documentation.

Can A or B connect a SAS-only port to a PCIe device?

Not through passive wiring alone. Mini SAS HD and SlimSAS identify connector families, not automatic protocol conversion. Both ports must expose compatible signals with an agreed-upon map.

Does SFF-8611 guarantee PCIe 5.0 operation?

No. The connector and assembly designation is not a test report specific to a generation. Establish the required rate and qualify the selected construction, length, and complete channel before committing to performance.

What cable length should I order?

Measure the installed route, including connector clearance and service access. Agree the length against the target generation and channel requirements. No single maximum can be promised for all five reference configurations.

Where does the U.2 model get drive power?

Model C has a separate SATA-style power input branch. It needs a compatible source with the rails and pinout required by the SSD. The OCuLink data connection does not provide power to the drive.

Does the 15-contact power connector provide every voltage rail?

Do not assume so. Housing contact count does not establish which rails are populated, their current capacity, or the requirements of a particular SSD. Confirm the harness drawing and power source before connection.

Is the angled model the same as the straight model?

No. E has a different termination and mating arrangement. Confirm its plug/socket combination, orientation, and clearance from the drawing. If it adds another mating interface, validate the complete connection rather than inheriting a direct-cable rating.

Can I hot-plug an OCuLink device?

Follow a hot-plug procedure only when the complete platform explicitly supports it. A cable latch provides retention and does not establish hot-plug support. Otherwise, power down the host and endpoint before installation or removal.

Will the direct cable work with any eGPU dock?

No universal compatibility is established. Check the host interface, dock connection, PCIe generation and width, firmware, operating system support, and whether the GPU has separate power. A cable alone cannot make an unsupported host work with an eGPU.

Why do some bandwidth figures look twice as large?

They may add transmit and receive capacity together. Compare figures on the same basis and distinguish encoded-data ceilings from application throughput. A bidirectional total is not the bandwidth available to a single-direction transfer.

What should I provide for a custom quotation?

Send the reference model, mating connector part numbers, host and endpoint documentation, pinout, length, exit direction, target generation, and quantity. Add power requirements for C, and agree on sample and acceptance terms before production.

How to Choose an OCuLink Cable for a Working System

A working OCuLink installation starts with a documented host-to-endpoint route. Identify the PCIe signals, mating interfaces, installed length, and any separate device power before choosing a cable. Those details let engineering and purchasing review the same connection throughout sample approval and ordering.

Begin with the Host and Endpoint

Record both equipment models and connector part numbers. Identify the host, endpoint, and required PCIe lane width. A port using a Mini SAS HD or SlimSAS housing may be assigned different signals by the board designer. When ordering A or B, supply the pin map rather than assuming the connector name defines the protocol.

For C, identify the U.2 SSD and confirm that the source provides the required NVMe PCIe connection. For an eGPU project, the host interface, dock electronics, firmware, and separate GPU power must all support the design. A passive cable cannot supply missing platform features.

Distinguish Interface Standards from Assembly Qualification

SFF-8611 describes cable-plug and assembly interfaces; it is not a blanket guarantee that every cable bearing the name meets any requested PCIe generation. Distinguish between internal and external implementations. Check shielding, retention, mating hardware, and system requirements for the intended installation.

Ask for the generation, length, and connector combination covered by the proposed assembly specification. Avoid treating a report for another construction as proof for your order. Where the application needs additional active signal conditioning, that must be part of the system design rather than assumed to exist inside a passive cable.

Read Bandwidth Claims in the Right Direction

A PCIe lane has separate transmit and receive paths. Adding both directions together produces a larger number, but it isn’t the capacity available for a single transfer. For illustration, PCIe 4.0 x4 has an encoded-data ceiling of about 7.88 GB/s per direction; PCIe 5.0 x4 is about 15.75 GB/s per direction, before transaction overhead. These are calculations for the link architecture, not tested ratings for every BC-DAI011 assembly.

Actual results depend on negotiated generation and width, workload, endpoint, and the complete channel. Define whether acceptance means successful link training, sustained application throughput, or another agreed measurement. This keeps a headline number from becoming the wrong purchasing criterion.

Review the Complete Physical Route

Measure the installed path, allowing for the connector body, supported bend, and release mechanism. E has a different angled termination arrangement from D; verify the exact mating faces and plug/socket combination before ordering. Mark both port orientations on a drawing rather than describing an angle without a viewing direction.

If the arrangement adds a mating interface or extends another lead, include the entire connection in validation. A short extension does not automatically inherit direct cable qualification. Keep the harness away from moving fans, sharp edges, and unsupported tension.

Plan Power Independently of Data

The C reference accepts drive power through its separate SATA-style branch. Check the required rails, pin assignments, and available load capacity with the SSD and supply documentation. A familiar power housing does not prove that all rails are present or that a modular PSU cable has the correct wiring.

Other devices, including GPU docks, may also require their own power arrangement. Do not expect an OCuLink data connection to replace that supply. Power down before fitting or removing the assembly unless the complete platform expressly supports the intended hot-plug procedure.

Make the Quote Specific Enough to Reorder

Send the reference suffix, board documentation, pinout, required generation, installed length, orientation, and quantity. Add environmental, labeling, and inspection requirements where relevant. Discuss sample availability and validate the chosen configuration on the intended equipment before fixing the production specification.

A clear connection brief makes the quotation useful to engineering and purchasing alike. Send your OCuLink cable requirements, including the two mating interfaces and the route you need.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top