Mini SAS Cable BC-DAI009 for Internal Storage Routing
- Route an internal storage link with the BC-DAI009 straight-to-side-exit assembly.
- A braided outer sleeve keeps the cable bundle together along the route.
- Use the 800 mm dimensioned example to begin length and housing-clearance checks.
- Match both mating interfaces and the contact assignment to your controller and backplane.
- Send the original cable reference, port photographs, and quantity for a replacement or OEM quotation.
Product Details
Route an internal storage connection around nearby hardware with the BC-DAI009 straight-to-side-exit cable assembly. The braided-sleeve layout redirects the cable beside one port, while the 800 mm dimensioned example gives your engineering team a starting point for reach and housing-clearance checks.
Before ordering, match both mating interfaces and the wiring required by your controller and backplane. “Mini SAS” is used for several connector families in purchasing requests; that alone isn’t enough to confirm a cable will fit or carry the intended signals. Send us your existing cable reference or a clear photo of the connector, and we can review the configuration with you.
BC-DAI009 Configuration Reference
| Item | Published product reference |
|---|---|
| Assembly reference | BC-DAI009 |
| Shown connector arrangement | One straight exit and one side exit, with release clips |
| Shown length | 800 mm on the published drawing; confirm measurement endpoints and tolerance for the order |
| Straight housing dimensions | 19.2 × 28.3 mm in the drawing; these are not a complete mating-interface specification |
| Side-exit housing dimensions | 31.4 × 19.7 mm in the drawing; allow additional space for the cable route and latch access |
| Outer construction | Braided sleeve as photographed; final material specification to be agreed |
| Contact drawing | A1–A18 and B1–B18 labels are shown; confirm connector identity, view direction and signal assignment against the endpoint documentation |
| Operating requirements | Protocol, link generation, length and complete-system acceptance criteria must be specified for the selected assembly |
Identify the Connector Before Comparing Prices
Internal Mini SAS, Mini SAS HD and SlimSAS are different connector families. Do not substitute one solely because the cable has a similar latch or a similar number of conductors. Compare the mating face, housing dimensions, and manufacturer part number.
If your equipment documentation explicitly names an interface, use the corresponding SFF-8087, SFF-8643, or SFF-8654 page as a comparison. Those links identify alternative families; they do not mean BC-DAI009 is interchangeable with all three.
A Side Exit Can Help, but the Surroundings Decide
The connector body is only part of the installation envelope. Check the direction the sleeved cable leaves the housing, whether the adjacent port remains usable, and whether you can still reach the release clip. A cover that presses on the cable can make an otherwise neat route unsuitable.
Use the dimensioned image to start a layout review, then check the actual sample in the intended enclosure. The drawing does not provide every mating dimension, tolerance, or allowable bend requirement. Resolve these before a new assembly becomes a production part.
Define Electrical Compatibility Separately
A passive internal cable carries the signals assigned by the host and backplane. Match the interface protocol, lane wiring, and any required sideband signals to the endpoint documentation. An NVMe application requires a suitable PCIe path throughout the connection; the cable does not add PCIe support to a SAS-only controller.
For a required operating rate, provide the controller and backplane models and the intended configuration. Agree on what the selected cable must demonstrate in that system. Record the agreed operating mode, assembly revision, and acceptance criteria with the sample approval.
Request a Defined Replacement or OEM Assembly
For a replacement, share the old part number, photos of both connector faces, overall length, and equipment model. For a new design, include connector drawings, the proposed route, and expected order quantity. Let us know whether you’re replacing an obsolete part, changing the exit direction, or establishing a repeatable production configuration.
Send these details for a quote. We can discuss assembly requirements and sample arrangements before you commit to a bulk order; we should confirm price, quantity, and delivery for the final configuration.
Use the Drawing to Check the Route
Plan reach and port clearance together using the 800 mm BC-DAI009 example. The drawing identifies the straight and side-exit housing dimensions; the order drawing records the final length, measurement endpoints, and tolerances for your build.
Allow room to operate each release clip and support the cable beside the port. Check the sample with adjacent cables and the cover installed, then record the routing and bend requirements for repeat assemblies.

No. Confirm the mating interfaces and contact assignment for both endpoints. The product name is a starting point, not a compatibility specification. An existing cable part number and equipment documentation are more useful than appearance alone.
No. The A and B contact labels identify positions in the illustrated connection, not the protocol supported by the host. Check signal names, connector view, and endpoint requirements against the approved drawing.
Only if the selected assembly and both endpoints are specifically configured for the required PCIe connection. A passive cable does not add NVMe support to a SAS-only controller. Provide the host and backplane references for review.
Label the two ends and mark the desired cable exit on a mating-face or top-view drawing. Include the latch orientation. Left and right can be reversed when viewing the same connector from the opposite side.
The published drawing shows an 800 mm example; it does not establish a universal maximum. Review a different length against the intended route, cable construction, and required electrical performance.
Ask for a sample quotation using the proposed connector pair, drawing, and length. Confirm availability, sample charges, and timing with the quotation, then validate mechanical fit and operation in your intended equipment.
Provide the assembly requirements, quantity, and requested delivery date. Minimum quantity, price, and schedule depend on the final configuration and supply conditions; obtain a written quotation rather than relying on a general website lead time.
How to Specify a Replacement Internal Storage Cable
An existing assembly can provide the references needed to specify a replacement internal storage cable. Record its connector geometry, wiring, installation direction, and equipment configuration so the replacement review covers both fit and operation before purchasing confirms price and delivery.
Record the Working Configuration
Photograph the installed route before removing the original cable. Label which end connects to the controller and which connects to the backplane. Record the equipment model, board revision, and any readable cable label. If the original system worked, these details provide a better reference than a general description such as “server storage cable.”
If the system never worked, say so. Matching an existing cable that was itself selected incorrectly can reproduce the same problem. Include the intended connection and the equipment documentation so that the requirement can be reviewed from the endpoints outward.
Photograph the Mating Faces
A side view shows the cable exit but can hide the connector part that determines fit. Supply a clear mating-face image, a top view showing the release mechanism, and a view of the matching port. Include a ruler for scale if no drawing is available, while recognizing that a photograph is not a precision measurement.
Keep both ends labeled throughout the review. A pin diagram viewed from the mating side is not the same as a diagram viewed from the termination side. Do not reverse a connector view or infer signal names from contact numbers alone.
Separate a Wiring Reference from a Performance Record
A continuity drawing describes which contacts connect. It does not establish insertion loss, operating rate, or application compatibility. Similarly, an illustration of shielding or conductors describes a construction concept, not a completed qualification test.
Ask for the information your application needs: the approved connection drawing, the intended operating mode, and the acceptance checks for the final assembly. For an OEM project, define any required inspection records before sample approval so that the production requirement is clear to both sides.
Specify Changes Without Losing the Baseline
If you need a longer cable or a different exit direction, identify that as a change from the original reference. Keep the electrical and mechanical requirements separate. A change that solves clearance may also change the route, strain relief, or electrical channel, so the revised assembly should not automatically inherit the original approval.
State the length measurement method and show where the cable will be supported. Avoid specifying only the distance between ports: the installed path may need additional reach around components, but unnecessary slack can obstruct airflow or removable hardware.
Approve the Sample as a System Component
Check fit with the enclosure closed and neighboring connections populated. Then verify operation in the intended host and backplane configuration. Record the tested assembly revision, equipment, and operating conditions so that a later repeat order refers to the same requirement.
A useful purchase reference includes the final drawing and cable identification, not just an image copied into an email. For a different storage connector family, start with our SAS cable selection. If you already have the original cable details, send them for a replacement review and let us know which aspects must remain unchanged.