MCIO Cable Assemblies for Internal Board Connections
- Connect internal MCIO interfaces and related storage endpoints with the BC-DAI010 range.
- Compare twenty straight, angled, and branched configurations.
- Select the 38-, 74-, 124-, or 148-contact format against the board drawing.
- Plan SlimSAS, Mini SAS HD, OCuLink, SATA, and U.2 terminations around the host signal map.
- Specify branch reach, labels, cable exit, and latch access for the assembled chassis.
- Send the target protocol, generation, and channel acceptance requirements for an OEM quotation.
Product Details
Connect internal boards, storage interfaces, and branched endpoints with BC-DAI010 MCIO cable configurations and related harnesses. Choose straight, angled, or fan-out layouts, then define lane mapping, sidebands, and installed length around your platform. A controlled assembly drawing gives engineering and purchasing the same reference for repeat builds.
MCIO means Mini Cool Edge IO. The name is associated with the SFF-TA-1016 connector family; it does not mean that every assembly carries every protocol used by equipment with that connector. Start with your board documentation, then select the matching wiring and mechanical layout.
Series Specification and Ordering Scope
| Item | What to specify |
|---|---|
| Series | BC-DAI010; individual suffixes identify the pictured reference configurations. |
| Construction | Internal passive cable assemblies; straight, angled, and breakout layouts shown below. |
| MCIO formats | The table lists 38-, 74-, 124-, and 148-contact options for the corresponding reference models. Confirm contact allocation and sidebands from the approved drawing. |
| Other terminations | Selected configurations use SFF-8654, Mini SAS HD, OCuLink, SATA data, or U.2 interfaces. Match the precise mating part and pinout. |
| Performance | State the protocol and generation. Acceptance depends on the specific construction and complete host-to-endpoint channel. |
| Routing | Specify installed length, branch lengths, connector orientation, and release-tab access. No single maximum length applies to every configuration. |
| Drive power | SATA data leads do not power drives. The U.2 reference includes a separate power branch needing a verified source and pinout. |
| Order definition | Confirm materials, conductor size, markings, inspection requirements, quantity, and delivery terms in the quotation. |
Choose by Connection, Not Just Connector Shape
| Requirement | Starting reference |
|---|---|
| Matching MCIO ports | A/B for compact formats; C/D or R/S/T for larger assemblies, subject to the board contact and lane map. |
| Different connector families | E/H/I/K/N/O, with an agreed signal assignment and common supported protocol. |
| Separate SATA drives | F, with a host exposing the required storage channels; drive power is separate. |
| U.2 SSD | G, with the correct NVMe lane map and verified power connection. One drive connector is pictured. |
| MCIO fan-out | P or U, with supported host topology and defined branch allocation. |
| Limited clearance | L/M/S/T, selected from a marked mating-face and enclosure drawing. |
| Guarded termination | J, ordered by the actual connector drawing rather than its legacy label alone. |
These references are a selection guide, not a universal compatibility list. A passive cable changes the physical route and pin assignment; it does not translate SAS into PCIe or add SATA support to a PCIe-only port.
Compare other interconnect families in our SAS cable collection. For a conventional drive data lead, the SATA cable range may be a more direct starting point.
Request a custom MCIO cable quotation with board and connector references, lane map, required lengths, and quantity.
MCIO and Related Cable Configurations
Choose from twenty configurations by connector pair, branch count, and exit direction. Use the board pinout and platform requirements to define the selected assembly, then confirm installed lengths and latch access in the chassis.

P/N: BC-DAI010-A
Connect matching internal MCIO interfaces with a compact, latched assembly. The 38-contact format is a starting point for an x4 design, not proof of a particular PCIe generation. Send the connector number and sideband map so the cable matches the complete channel.

P/N: BC-DAI010-B
Route an eight-lane connection between matching MCIO interfaces with straight, latched terminations. The sleeved bundle keeps the route together through the chassis. Provide host and endpoint pin assignments, sidebands, and target operating mode so the selected length can be reviewed as part of the complete channel.

P/N: BC-DAI010-C
Choose the 124-contact assembly when your board drawing calls for this connector size. Contact allocation depends on high-speed pairs, grounds, and sidebands. Specify the actual lane map rather than ordering from an x20 label alone, particularly when independent links share the assembly.

P/N: BC-DAI010-D
This larger MCIO format has a different contact arrangement from the compact versions. Match the receptacle, grounding, and sideband requirements to the approved drawing. A high contact count alone does not define a single PCIe x24 link or guarantee accelerator compatibility.

P/N: BC-DAI010-E
Route between the pictured SFF-8654 8i and MCIO formats when both ports carry compatible signals. This passive wiring assembly is not a SAS-to-PCIe converter. Provide both board manuals and the required signal map before choosing a production configuration and installed cable length.

P/N: BC-DAI010-F
Eight separately terminated SATA data leads route a compatible storage connection to individual drives. The MCIO-shaped source must expose the required SATA or supported SAS controller channels. This harness does not turn a PCIe-only port into SATA, and each drive still needs separate power.

P/N: BC-DAI010-G
Connect one U.2 drive using an MCIO data path and separate power-input branch. This layout brings the SSD connection and supply feed into one planned harness route. Confirm the host lane allocation, SFF-8639 wiring, source pinout, and SSD power requirements in the approved assembly drawing.

P/N: BC-DAI010-H
Two OCuLink branches provide a physical fan-out from the SlimSAS connector pictured. Specify the source protocol, branch assignment, and any required PCIe bifurcation. The cable does not convert a SAS controller into a PCIe host or create additional lanes beyond those available at the source.

P/N: BC-DAI010-I
The reference shows paired Mini SAS HD connections and two OCuLink terminations. Confirm both source ports and each branch map against the drawing. Do not treat the paired block as an interchangeable single eight-lane port; establish protocol compatibility separately from mechanical fit.

P/N: BC-DAI010-J
Guarded, latched terminations and blue pull tabs give this internal assembly a distinct mating and release arrangement. Specify J using the actual connector drawing, including the receptacle reference, orientation, and clearance. Agree the handling procedure and required channel performance for the selected build before sample approval.

P/N: BC-DAI010-K
Two Mini SAS HD branches offer a routing option for a compatible controller or backplane design. Check signal assignment, sidebands, and host operating mode before ordering. A passive fan-out cannot add a protocol controller, PCIe switch, or missing storage channels to the system.

P/N: BC-DAI010-L
Side-exit terminations can keep the bundle clear of a lid, fan, or adjacent board. Define left and right from a marked mating-face drawing, since viewing direction changes the apparent orientation. Include latch access and the first supported bend in your enclosure review.

P/N: BC-DAI010-M
The angled connector provides a different cable exit from the straight reference assembly. Check connector height, board orientation, and pull-tab access rather than choosing based on a 90-degree description alone. Use a marked enclosure photo to show the required route and prevent reversed orientation.

P/N: BC-DAI010-N
Route two OCuLink branches where the host lane map supports the intended endpoints. Confirm branch labels, sideband wiring, and firmware settings before installation. This internal assembly is not automatically an external OCuLink cable or a universal plug-and-play expansion connection for every matching receptacle.

P/N: BC-DAI010-O
Two SFF-8654 4i-style branches provide a compact route from the MCIO termination. Send the pin map for both ends and identify the intended protocol. Connector names alone can’t determine whether the link is NVMe, SAS, or SATA, and a passive cable cannot translate between those protocols.

P/N: BC-DAI010-P
Two smaller MCIO terminations distribute the available route into separate branches. For independent PCIe endpoints, confirm that the source supports the required split and sideband allocation. The harness supplies wiring only; it does not add bifurcation support or function as a PCIe switch.

P/N: BC-DAI010-R
The straight x16 reference suits layouts with room for the bundle to leave along the connector axis. Match contact count and sidebands to the board drawing. Select the final length from the installed route and channel requirements, not from a nominal lane-width label alone.

P/N: BC-DAI010-S
An angled x16 assembly can reduce interference where straight connectors crowd a cover or neighboring hardware. Confirm mating orientation and the connector envelope before sampling. The pictured geometry does not establish a common speed rating with every other MCIO cable in the series.

P/N: BC-DAI010-T
Opposing side-exit terminations provide another routing option for wide internal links. Mark both mating faces, cable direction, and latch-access space on the drawing. This helps avoid approving a cable that fits electrically but cannot be installed or released once the chassis is assembled.

P/N: BC-DAI010-U
Route a wide connection into two MCIO branches using an agreed lane and sideband map. Where independent PCIe links are needed, the platform must support that topology. This passive assembly does not double bandwidth or replace the switch, controller, or firmware configuration required by the design.
Plan the Breakout Before Ordering
A dual-MCIO branch layout can route separate links to endpoints positioned in different parts of the chassis. Define the host topology, lane assignment, and sidebands first, then size each branch so it reaches without loading the other connector.
Send a marked board drawing with the mating interfaces, branch labels, and required channel performance for review. Confirm the source supports the intended independent links; the passive harness provides the agreed wiring and does not act as a switch.

MCIO means Mini Cool Edge IO. SFF-TA-1016 identifies the associated connector family. Neither the name nor the mechanical fit alone establishes pinout, protocol, or tested data rate.
No. These are passive wiring assemblies. They don’t convert SAS to PCIe, USB4, or Ethernet, add a storage controller, or generate extra host lanes.
No. Confirm the exact assembly and complete channel against the required generation. PCIe 5.0 runs at 32 GT/s, and PCIe 6.0 runs at 64 GT/s; a connector-family designation is not a performance metric.
Use the board connector drawing and signal allocation. Grounds and sidebands affect the available arrangement. Do not order solely from an x20 or x24 label, or assume it represents one standard PCIe link of that width.
No. F needs appropriate storage channels and wiring at the source. A PCIe-only MCIO port cannot become SATA through this passive harness. Supply drive power separately.
The reference photograph shows one U.2 drive connector and a separate power-input branch, not eight drive outputs. Confirm the host lane map, SSD interface, and power-source pinout before ordering.
No. The host and firmware must support the topology, and the cable must route lanes and sidebands correctly. A passive split is not a PCIe switch and cannot enable unsupported independent links.
Not by itself. Both ports must expose compatible signals with a matching map. A connector adapter cannot translate SAS into PCIe. Provide the controller and endpoint documentation for review.
J uses guarded terminations and blue pull tabs. Match the mating connector part number and housing dimensions to the equipment drawing, then check release access. Hot-plug support and operating performance depend on the specified assembly and complete platform; the housing alone does not establish them.
There is no single qualified maximum for every reference model. Specify the protocol, generation, board channel, and route. Agree on the order-specific length and acceptance requirements before treating the assembly as suitable for the design.
Mark the mating face, latch position, and desired exit on a drawing or enclosure photo. Include height and release-tab access. Left, right, and downward descriptions can reverse when viewed from the opposite side.
F provides SATA data leads only. G has a separate power-input branch for its U.2 connection, but the source voltage, pinout, and load need confirmation. A matching housing alone is insufficient for a safe power connection.
Do not assume so. Confirm the internal or external interface, shielding, retention, and equipment requirements. The pictured internal assemblies are not automatically interchangeable with a complete external cable system.
No common conductor, shielding, or temperature specification is established by these photos. Define the selected assembly materials, environmental requirements, and supporting evidence in the quotation.
Share the route, branch identifiers, and orientation for review. Feasibility, samples, markings, and production terms depend on the defined configuration; the reference photo alone does not establish them.
Send board and connector part numbers, protocol, lane width, sidebands, installed lengths, orientation, quantity, and target acceptance evidence. Include drive power requirements for a U.2 harness.
For a new platform connection, sample validation is a practical step. Check installation, pin mapping, and operation on the intended host and endpoints, including the required link rate. Agree on acceptance criteria and sample terms before production.
How to Specify an MCIO Cable Without Losing a Design Cycle
A clear MCIO cable specification connects the board requirements to an installable assembly. Record the port roles, lane and sideband map, mechanical route, and target operating mode before sample approval. Purchasing can then compare quotations and reorder against the same defined build.
Identify Both Ports and Their Electrical Roles
Record the board and mating connector part numbers, host or endpoint role, protocol, and required lane width. A SlimSAS, Mini SAS HD, or MCIO housing does not tell you which signals the board designer assigned to it. If the boards do not expose compatible signals, a passive harness cannot resolve the mismatch.
For a SATA fan-out, identify whether the source is a SATA-capable controller or a compatible SAS controller. For NVMe, establish the PCIe route and required sidebands. Describing either project only as a storage cable leaves too much room for an incorrect assumption.
Separate Contact Count from Lane Allocation
Contacts may carry high-speed pairs, grounds, and sideband signals. Different implementations can use larger MCIO formats differently. A 124- or 148-contact connector is therefore not, by itself, a promise of one standard PCIe x20 or x24 link. Put the actual arrangement and pin assignments on the drawing.
Breakouts need a branch map. Mark which lanes reach each termination and how reset, presence, management, or other required signals are handled. For P and U configurations, verify the source can operate the intended independent links; a cable cannot enable an unsupported split in firmware.
Set a Channel Target, Not an Unqualified Speed Claim
PCIe 5.0 uses 32 GT/s signaling, while PCIe 6.0 uses 64 GT/s with PAM4. These generation-level rates are not measured application throughput and are not interchangeable with a generic 112 Gbps claim. Selecting the connector is only part of meeting a channel target.
Board traces, vias, mating interfaces, and cable length all contribute to the channel. Define the required generation, topology, and acceptance evidence for the ordered assembly. Qualification at one length or connector combination does not establish performance for every variant. A retimer, where required, is an active system component—not something a passive cable silently provides.
Review the Route in the Assembled Chassis
Measure the route rather than the straight-line distance between ports. Allow room for the connector body, first supported bend, latch release, and service access. An angled plug can solve a clearance problem, but the wrong direction creates another. A photo marking both mating faces and the desired exit is more useful than the word right-angle alone.
Branch lengths should reach their destinations without pulling one connector while another is installed. Keep the bundle clear of sharp edges, fans, and hot components. Request an order-specific bend requirement rather than assuming that sleeving makes the assembly suitable for repeated flexing.
Check Drive Power and Serviceability Separately
F carries SATA data, not drive power. G has one U.2 connector and a separate power input; that input must match the source, voltage rails, and SSD load. Similar-looking modular power housings are not proof of a common pinout.
Power down before installation unless the complete platform expressly supports the intended service procedure. A pull tab or guarded housing does not make a connection hot-pluggable. Check that technicians can release the latch without pulling on conductors.
Turn a Reference Model into a Repeatable Order
Send the suffix, board manuals, connector drawings, lane and sideband map, installed lengths, and quantity. Add target performance evidence, labels, and inspection requirements. You can then establish sample availability and production terms against a defined configuration in the quotation.
The aim is simple: a cable that fits the enclosure, connects the intended signals, and can be reordered against the same specification. Send your MCIO connection details to start with fewer assumptions.