Specify a retained USB-A to Mini-B connection for equipment with matching screw receivers. The BC-DAE004 family offers eight housing and color options with 13mm or 15mm mounting-hole spacing, helping buyers match the panel geometry, cable exit, and service access.
- USB-A male to five-pin Mini-B male with screw-retention housing
- Eight BC-DAE004 models with 13mm or 15mm mounting-hole spacing
- Black and purple options, including down- and up-angle variants
- Listed lengths: 0.5m, 1m, 2m, 3m and 5m
- USB 2.0 signaling up to 480Mbps with compatible equipment
- Confirm mating-hole pattern, screw thread, engagement, and housing clearance before ordering
Match the Mini-B Housing to Your Equipment Mounting
A USB-A to Mini-B cable may provide the required electrical connection, while a fixed equipment installation also needs mechanical retention. The BC-DAE004 family adds two locking screws at the Mini-B housing for equipment with a matching mounting arrangement. Eight listed models cover 13mm and 15mm hole spacing, different housing profiles, black or purple construction, and down- or up-angle exits.
Select the mating hardware before choosing a color or cable length. Hole spacing is not screw-thread pitch, and a 13mm or 15mm dimension does not tell you which screw thread the device accepts. Use the equipment drawing and cable drawing together.
Eight-Model Reference
| Part number | Listed housing/color | Mounting-hole spacing |
|---|---|---|
| BC-DAE004-A13B | A-profile / black | 13mm |
| BC-DAE004-A13P | A-profile / purple | 13mm |
| BC-DAE004-D15P | Down-angle / purple | 15mm |
| BC-DAE004-U15P | Up-angle / purple | 15mm |
| BC-DAE004-B15P | Flat B-profile / purple | 15mm |
| BC-DAE004-B15B | Flat B-profile / black | 15mm |
| BC-DAE004-C15P | Raised C-profile / purple | 15mm |
| BC-DAE004-C15B | Raised C-profile / black | 15mm |
Use the product images to identify the housing family, then confirm all mating dimensions on the approved drawing. Color is an identification option, not a different electrical standard.
Specification and Assembly Requirements
| Parameter | Selection information |
|---|---|
| Interfaces | USB 2.0 Type-A male to five-pin Mini-B male |
| Retention | Two screws at the Mini-B housing; requires matching equipment hardware |
| Data capability | Up to 480Mbps USB 2.0 signaling; actual throughput depends on the connected system |
| Listed lengths | 0.5m / 1m / 2m / 3m / 5m; confirm the selected model and length combination |
| Jacket and molding | Black or purple PVC as listed by model |
| Thread and engagement | Confirm thread specification, usable screw length, engagement and installation torque from the mating drawings |
| Conductors, shields and finish | Confirm material, gauge, shielding termination and contact/shell finish in the order specification |
| Power function | Subject to source, device and cable construction; locking screws do not increase available USB power |
| Environmental / motion use | Requires application-specific construction and evidence; no general drag-chain, oil-resistance or vibration rating implied |
Retention Is Only One Part of a Reliable Installation
Matching screws can help resist unintended unplugging, but they do not make every system vibration-proof. The connector must seat correctly, the hardware must engage without bottoming out, and the cable must be supported so movement doesn’t transfer directly into the socket.
For a moving assembly, provide the travel, bend geometry, cycle target, and environment. A flexible-looking PVC cable is not automatically a continuous-flex cable. Review dynamic performance separately from the retention feature.
Choose the Housing Around the Panel
Check the connector opening, screw access, and space around both sides of the Mini-B port. Compare flat and raised profiles against any recess or neighboring hardware. For D and U variants, approve the cable exit against a photo of the device in its installed position.
If the device has no matching screw receivers, compare the standard straight Mini-B cable or the four-angle Mini-B cable. Do not force locking hardware onto an ordinary port.
Prepare a Quotation Request
Send the device model, connector and mounting drawing, desired BC-DAE004 suffix, cable route and length, quantity, and operating conditions. Include any required inspection or test documentation. A reviewed mechanical specification is more useful than a general request for an industrial USB cable.
Compare 13mm and 15mm Mounting Options
Start with the mounting-hole spacing and housing profile, then select color, exit direction, and cable length. Compare the eight models below. Confirm the screw thread and engagement separately; the 13mm and 15mm values describe mounting-hole spacing, not thread size.

P/N: BC-DAE004-A13B
Mounting-hole spacing: 13mm
The black A-profile model lists 13mm mounting-hole spacing. Compare the housing and screw locations with the equipment drawing, then confirm thread and engagement details. Use the black finish where it suits the installation identification scheme and approved cable construction.

P/N: BC-DAE004-A13P
Mounting-hole spacing: 13mm
The purple A-profile model retains the listed 13mm mounting-hole spacing while providing a visible color identifier. Check the mating geometry and cable specification independently of color, and confirm that both screws can engage correctly without forcing the Mini-B plug into place.

P/N: BC-DAE004-D15P
Mounting-hole spacing: 15mm
The purple down-angle version combines the D housing exit with 15mm mounting-hole spacing. Match the installed socket view to the product image and allow room for screw access, the molded bend, and the cable route beyond the strain relief.

P/N: BC-DAE004-U15P
Mounting-hole spacing: 15mm
The purple up-angle version offers the U housing arrangement with 15mm mounting-hole spacing. Compare its exit with the D model in the installed port orientation. Confirm clearance above the connector and access to both retaining screws before approving a sample.

P/N: BC-DAE004-B15P
Mounting-hole spacing: 15mm
The purple flat B-profile model lists 15mm mounting-hole spacing. Review its housing envelope against the panel opening and adjacent hardware, rather than selecting based on spacing alone. Record the approved profile, screw specification, and cable length on the order.

P/N: BC-DAE004-B15B
Mounting-hole spacing: 15mm
The black flat B-profile model provides the listed 15mm mounting-hole spacing in a black finish. Check housing clearance, screw alignment, and the required cable route with the equipment drawing. A matching color does not replace approval of the electrical and mechanical specifications.

P/N: BC-DAE004-C15P
Mounting-hole spacing: 15mm
The purple raised C-profile model uses the listed 15mm mounting-hole spacing. Compare the raised housing contour with the available recess and neighboring connectors, and leave room to operate both screws. Confirm the complete envelope before substituting it for a flatter housing.

P/N: BC-DAE004-C15B
Mounting-hole spacing: 15mm
The black raised C-profile model combines a distinct housing contour with 15mm mounting-hole spacing. Use the drawing to check recess depth, surrounding clearance, and screw engagement. Select the cable length based on the final installed route and required service movement.
Check the Plug and Both Retaining Screws
The Mini-B housing carries two retaining screws beside the connector. These must match the equipment mounting arrangement; the screws should not be used to pull an incorrectly aligned plug into the socket.
Check the mounting-hole spacing, housing envelope, and usable screw engagement together. Support the cable separately so the port and locking hardware alone don’t carry routine movement.

The listed 13mm and 15mm mounting-hole spacings suit different equipment layouts. Match the exact drawing. Hole spacing is separate from screw diameter and thread pitch, so you can’t use it alone to choose an M2.5 or M3 screw.
Continuous-flex use requires a construction and test specification for that duty. Provide travel, bend radius, speed, cycle target, and operating environment for review, then request evidence for the approved assembly.
Confirm the actual foil, braid, and termination details for the ordered assembly. Shielding can help manage interference but does not provide electrical isolation or guarantee noise-free operation. Evaluate the cable as part of the complete equipment system.
Black and purple can help identify routes or equipment groups. Also keep the exact model and specifications on the label or order record. Color alone does not identify thread size, cable length, or electrical performance.
Use the screw thread, length, and torque specified by the mating equipment and the approved cable drawing. Do not infer them from the 13mm or 15mm hole spacing. Incorrect hardware can damage threads or prevent the connector from seating properly.
Do not assume oil or chemical resistance from a PVC description. Identify the fluid, concentration, temperature, and exposure duration for material review. Request applicable evidence for the selected jacket before specifying it for that environment.
The listed lengths are 0.5m, 1m, 2m, 3m, and 5m. Confirm the selected model and validate the complete link, including the power load. Locking screws and shielding do not extend USB reach or guarantee identical performance at every length.
Send the mounting pattern, thread details, housing space, and quantity for feasibility review. Quote custom tooling, minimum quantity, and lead time for the requested design. Do not substitute a different spacing without verifying compatibility with the mating equipment.
Provide the required operating and storage temperatures for the full assembly. Review the selected jacket, molding, and connector components together, and request evidence against the temperature criteria for the ordered model.
A compatible host can communicate with a supported USB 1.1 Mini-B peripheral at that device’s speed. Check the interface, software, and function. The cable does not increase the peripheral’s rate, and the retention hardware must still match.
No. The device needs matching screw receivers and enough housing clearance. If it has a standard Mini-B socket without that mounting arrangement, choose an appropriate standard cable instead of forcing the screws or housing against the equipment.
Approving the Mechanical Fit of a Locking Mini-B Cable
A locking cable order needs more than the connector name and distance between two holes. The housing, panel opening, screw receivers, and cable route form one mechanical assembly. Reviewing them together helps avoid a cable that plugs in but cannot be secured correctly.
Separate Hole Spacing from Thread Specification
The listed 13mm and 15mm values describe the mounting-hole spacing. They do not establish screw diameter, thread pitch, engagement length, or torque. Obtain those details from the equipment and cable drawings before ordering or choosing replacement hardware.
Check whether the receivers are part of the device chassis, a separate bracket, or another mounting feature. Confirm the allowable engagement so a screw doesn’t bottom out before the housing seats. Do not infer a screw size from a photograph or from another product with the same spacing.
Compare the Whole Housing Envelope
Use the A, B, C, D, or U model image to identify the desired family, then check the drawing against the panel. Include recessed openings, adjacent ports, and the clearance needed to grip or operate the screws. For angled models, mark the desired cable exit on a photo of the installed equipment.
Black and purple can help identify cable routes, but color doesn’t indicate a different speed, thread, or environmental rating. Keep the complete part number with the approved drawing so appearance isn’t the only purchasing reference.
Seat and Support the Connection Correctly
Follow the equipment instructions for installation. Align the connector without force and use the specified retention procedure. The screws should retain a correctly seated plug, not compensate for an unsuitable housing or misaligned socket.
Provide support along the cable route and enough slack for service movement. A tightly secured connector can still be damaged if the cable repeatedly pulls or levers against it. Also check the USB-A end, since Mini-B retention does not secure the host-side plug.
Evaluate the Real Operating Conditions
If the equipment moves, define travel, bend geometry, speed, and cycle requirements before approving the cable construction. If oil, cleaning chemicals, or unusual temperatures are present, identify the exposure and required acceptance criteria. A PVC jacket and locking screws do not make the cable suitable for all of these conditions.
Perform the intended data operation with the selected length and equipment. For bus-powered devices, evaluate operation under the expected load. Where vibration or other environmental testing is required, agree on the test method and evidence for the actual assembly rather than relying on a generic ruggedness label.
Make the Approved Sample Traceable
Keep the cable suffix, length, screw specification, drawing revision, and sample result together. Add identification labels where technicians need to distinguish visually similar assemblies. If the panel, connector, or routing changes later, review the fit again before reordering.