x
Send Your Inquiry Today
Quick Quote
  • Ethernet Panel Mount Cable: RJ45 cable with integrated mounting flange for secure panel installation.
  • BC-DAJ011-U8 panel mount RJ45 female socket with mounting ears and an up-angle male plug
  • BC-DAJ011-D8 panel mount RJ45 female socket with mounting ears and a down-angle male plug
  • BC-DAJ011-L8 panel mount cable with a left-angle RJ45 male plug and female socket with mounting ears
  • Ethernet Panel Mount: Provides a clean, professional network access point on equipment panels.
  • BC-DAJ011-S6 panel mount cable with a straight RJ45 male plug and female socket with mounting ears
  • BC-DAJ011-U6 panel mount cable with an up-angle RJ45 male plug and straight female housing
  • BC-DAJ011-D6 panel mount cable with a down-angle RJ45 male plug and straight female housing
  • BC-DAJ011-L6 panel mount cable with a left-angle RJ45 male plug and straight female housing
  • BC-DAJ011-R6 panel mount cable with a right-angle RJ45 male plug and straight female housing
  • Four RJ45 male-plug cable exits labeled up, down, left and right, with latch positions visible
  • Reference dimensions for an RJ45 female housing with two mounting ears and an attached male-plug cable
  • Ethernet Panel Mount Cable: RJ45 cable with integrated mounting flange for secure panel installation.
  • BC-DAJ011-U8 panel mount RJ45 female socket with mounting ears and an up-angle male plug
  • BC-DAJ011-D8 panel mount RJ45 female socket with mounting ears and a down-angle male plug
  • BC-DAJ011-L8 panel mount cable with a left-angle RJ45 male plug and female socket with mounting ears
  • Ethernet Panel Mount: Provides a clean, professional network access point on equipment panels.
  • BC-DAJ011-S6 panel mount cable with a straight RJ45 male plug and female socket with mounting ears
  • BC-DAJ011-U6 panel mount cable with an up-angle RJ45 male plug and straight female housing
  • BC-DAJ011-D6 panel mount cable with a down-angle RJ45 male plug and straight female housing
  • BC-DAJ011-L6 panel mount cable with a left-angle RJ45 male plug and straight female housing
  • BC-DAJ011-R6 panel mount cable with a right-angle RJ45 male plug and straight female housing
  • Four RJ45 male-plug cable exits labeled up, down, left and right, with latch positions visible
  • Reference dimensions for an RJ45 female housing with two mounting ears and an attached male-plug cable
P/N: BC-DAJ011

Ethernet Panel Mount Cables for Enclosure Integration

Add an accessible RJ45 socket to an enclosure with a BC-DAJ011 Ethernet panel mount cable. The pictured female housing uses two mounting ears and a lead attached to a straight or angled RJ45 male plug.

  • Ten configurations across standard and slim cable families.
  • Straight, up, down, left, and right male-plug orientations.
  • Confirm panel cutout, hole spacing, thickness, and rear clearance.
  • Discuss 0.5, 1, 1.5, 2, 3, or 5m finished lengths.
  • For indoor, dry installations unless a separately specified protected assembly is agreed.
  • Review target Ethernet speed and PoE requirements for the full connection.

Product Details

An enclosure should offer an easily accessible network port without exposing the internal equipment connection. BespokeCable’s BC-DAJ011 Ethernet panel mount range provides a mountable RJ45 female socket with an attached lead to an RJ45 male plug.

Two mounting ears secure the female housing to the panel. Choose the plug orientation and cable length around the internal layout, then confirm the panel drawing before fabrication. This gives enclosure builders a clearer basis for sampling and repeat production.

Panel Mount Assembly Requirements

ItemSpecification to confirm
SeriesBC-DAJ011
Panel interfaceRJ45 female socket in a housing with two mounting ears
Cable endRJ45 male plug, straight or angled according to model
Families listedStandard Cat 6 and slim Cat 8 configurations; confirm actual construction and required performance evidence
Length references0.5, 1, 1.5, 2, 3 and 5m, or a requested finished length; confirm availability by model
Mounting detailsPanel opening, mounting-hole spacing, panel thickness, and fasteners from the selected drawing
Internal routingPlug direction, rear clearance, bend space and cable support
Conductor and shieldingSpecify gauge, conductor material, and shield construction; do not infer them from the socket trim
EnvironmentNo IP rating is claimed for these standard pictured assemblies; plan for indoor, dry use
Power and dataAgree the target Ethernet application and any PoE requirements for the complete connection
Order detailsQuantity, labels, packaging, sample and acceptance documentation

Ten Model References for Layout Selection

Male-plug orientationStandard familySlim family
StraightBC-DAJ011-S6BC-DAJ011-S8
Up angleBC-DAJ011-U6BC-DAJ011-U8
Down angleBC-DAJ011-D6BC-DAJ011-D8
Left angleBC-DAJ011-L6BC-DAJ011-L8
Right angleBC-DAJ011-R6BC-DAJ011-R8

Confirm angle names against the illustrated latch position and your equipment view. They describe the cable-end plug orientation, not a promise that the panel socket itself faces upward or sideways.

Check the Drawing Before Cutting the Panel

The reference image shows approximately 27.8mm mounting-hole spacing, 37mm housing width, and 23mm height for the illustrated housing. It is not a universal cutout specification for every variant. Request the approved drawing for the selected model, including the connector opening, tolerances, panel thickness, and fastener arrangement.

Use the selected rectangular socket opening and fixing-hole layout when preparing the panel. Allow space behind the socket for the housing, cable exit, and a supported bend. Also check that you can insert and remove the external plug after the enclosure is assembled.

Choose the Plug Exit for the Internal Equipment

A straight plug may suit an open route. An angled plug helps when a board or device port sits close to a wall, cover, or another connector. Provide a photo of the mating port with its latch position visible, and mark the desired cable direction.

For enclosure designs that need only an inline connection rather than a fixed port, compare the Ethernet extension cable configurations. Use a fixed panel socket when the enclosure needs a repeatable external connection point.

Separate Mounting from Electrical and Environmental Performance

Fastening the housing helps locate the socket; it does not lock a standard mating RJ45 plug or establish vibration, marine, or waterproof approval. A metal socket surround also does not provide a fully shielded cable or a defined grounding path.

The assembly is passive. Include it, along with the external lead, equipment ports, and other cabling, when evaluating speed and PoE. Cat 8 terminology does not guarantee 25/40Gbps through every panel connection, and a slimmer cable does not automatically provide the same power margin as a larger-gauge construction.

Prepare a Repeatable OEM Specification

Send the enclosure drawing, selected model, finished length, and quantity. Include device-port details, target speed, PoE load, and required documentation. Review labels and packaging for the production workflow.

Use a sample to check panel fit, latch access, and internal routing before committing to a production panel. Agree on the electrical acceptance requirements separately and keep the approved configuration with the purchase order.

Request an Ethernet panel mount cable quotation with your enclosure drawing, finished length, and quantities.

Ethernet Panel Mount Cable Configurations

Create a serviceable RJ45 port on an enclosure while routing the attached lead to the internal equipment. Compare ten straight and angled male-plug configurations in standard and slim families. Each female housing has mounting ears; select the port location, plug exit, and finished length around your panel layout.

Ethernet Panel Mount Cable: RJ45 cable with integrated mounting flange for secure panel installation.
Cat8 Slim Ethernet Panel Mount Cable

P/N: BC-DAJ011-S8

The straight slim configuration connects a mountable female socket to a straight RJ45 plug. Review rear housing clearance and the managed cable route inside the enclosure. Confirm construction and complete-link requirements separately from the slim-profile choice.

BC-DAJ011-U8 panel mount RJ45 female socket with mounting ears and an up-angle male plug
Up Angle Cat8 Slim Ethernet Panel Mount Cable

P/N: BC-DAJ011-U8

Use the slim up-angle plug when the equipment port needs the cable exit shown. Match the latch direction to your device before ordering. Include the panel drawing and required length so both ends can be checked together.

BC-DAJ011-D8 panel mount RJ45 female socket with mounting ears and a down-angle male plug
Down Angle Cat8 Slim Ethernet Panel Mount Cable

P/N: BC-DAJ011-D8

This slim down-angle option redirects the lead at the male plug. Check the space around the mating port and preserve access to its latch. The female housing still needs its own approved panel opening and mounting arrangement.

BC-DAJ011-L8 panel mount cable with a left-angle RJ45 male plug and female socket with mounting ears
Left Angle Cat8 Slim Ethernet Panel Mount Cable

P/N: BC-DAJ011-L8

Review the slim left-angle configuration where a side route is needed inside the enclosure. Confirm the viewing direction with a photo of the port. Include any PoE load and target data rate when specifying the final cable construction.

Ethernet Panel Mount: Provides a clean, professional network access point on equipment panels.
Right Angle Cat8 Slim Ethernet Panel Mount Cable

P/N: BC-DAJ011-R8

The slim right-angle plug provides an alternative side-exit route for equipment in confined layouts. Confirm latch orientation and adjacent-port clearance. Request a fit sample for space-constrained enclosures, and agree on the final electrical specification before production.

BC-DAJ011-S6 panel mount cable with a straight RJ45 male plug and female socket with mounting ears
Cat6 Ethernet Panel Mount Cable

P/N: BC-DAJ011-S6

Use the standard straight configuration as a starting point for an accessible panel socket and an uncomplicated internal route. Check housing depth, cable support, and plug access. Specify the length and required network application in the enclosure drawing.

BC-DAJ011-U6 panel mount cable with an up-angle RJ45 male plug and straight female housing
Up Angle Cat6 Ethernet Panel Mount Cable

P/N: BC-DAJ011-U6

The standard up-angle male plug can help route the lead near an equipment wall or cover. Confirm the pictured direction against your socket. Keep enough space behind the panel housing for cable support and servicing.

BC-DAJ011-D6 panel mount cable with a down-angle RJ45 male plug and straight female housing
Down Angle Cat6 Ethernet Panel Mount Cable

P/N: BC-DAJ011-D6

Review this standard down-angle version when the required plug exit matches the illustration. Check the latch and nearby components before selecting it. Include the panel thickness, mounting drawing, and finished length so the assembly fits the enclosure.

BC-DAJ011-L6 panel mount cable with a left-angle RJ45 male plug and straight female housing
Left Angle Cat6 Ethernet Panel Mount Cable

P/N: BC-DAJ011-L6

The standard left-angle plug supports a planned lateral route inside the equipment. Confirm the direction using the latch as a reference rather than the product name alone. Share the required category, length, and acceptance criteria alongside the mechanical layout.

BC-DAJ011-R6 panel mount cable with a right-angle RJ45 male plug and straight female housing
Right Angle Cat6 Ethernet Panel Mount Cable

P/N: BC-DAJ011-R6

This standard right-angle option pairs a side-exit male plug with the mountable female housing. Check clearance at both ends and support the internal lead. Confirm the final drawing before preparing panel holes or ordering a production batch.

Approve the Panel Interface Before Fabrication

A panel socket needs more than a hole that looks close enough. Confirm the opening, mounting-hole spacing, panel thickness, and the space occupied by the housing behind the surface.

The reference drawing illustrates one mounting-ear version. Use the approved model-specific drawing for fabrication and check a sample in the actual panel. Do not assume these assemblies fit an M16 round opening or that every housing shares identical dimensions.

Reference dimensions for an RJ45 female housing with two mounting ears and an attached male-plug cable
What is an Ethernet panel mount cable?

It is an RJ45 female socket in a mountable housing with an attached lead to an RJ45 male plug. The pictured BC-DAJ011 versions use mounting ears to locate a network connection on an enclosure panel.

What’s the benefit compared to a regular RJ45 jack and an independent cable?

An integrated assembly provides a defined lead between the panel socket and equipment plug, which can simplify routing and purchasing. Select it when the mounting interface, internal cable route, and equipment connector suit the enclosure. Confirm panel fit and complete-link performance with the proposed assembly.

What size hole do I need to make in the panel?

Use the approved drawing for the selected housing, including its socket opening and fixing holes. The illustrated version shows 27.8mm mounting-hole spacing, but that is not a universal cutout specification. These pictured assemblies should not be assumed to fit a 16mm M16 round hole.

When should I choose an angled male plug?

An angled male plug can help route the internal lead around a nearby wall or component. Match the latch position and desired exit to the equipment view. The direction label does not mean the panel-mounted female socket faces that direction.

What distinguishes the Cat6 from the Slim Cat8?

They are listed as different cable families and profiles. Confirm the actual construction and required performance evidence for the selected model. A Cat 8 label does not guarantee 25/40Gbps through every panel connection, and the complete channel remains relevant.

Are these cables shielded?

Specify the shielding required for the complete assembly. A metal surround at the socket does not provide cable shielding or termination. Review the selected construction and how it connects to the system shielding and grounding design.

Are they waterproof (IP-rated)?

No IP rating is claimed for the standard pictured assemblies. Use them in a suitable indoor, dry installation. If the port must be exposed to water or dust, specify the required protected mating system and enclosure rating separately.

Can I choose a custom cable length?

Provide the final length and tolerance for each model and quantity. The listed references include 0.5, 1, 1.5, 2, 3, and 5m. Confirm availability and include the actual internal route and service allowance.

What’s your MOQ (minimum order quantity)?

MOQ depends on the model, length, and customization. Send quantities per configuration and any label or packaging requirements so the quotation can state the applicable minimum and sample terms.

Will you support other connector types (USB, etc.) in a panel-mount style?

Other interface requirements can be reviewed as separate assemblies. Provide the connector type, panel drawing, and intended application. USB and Ethernet mounting or electrical specifications are not interchangeable simply because both use a panel housing.

How do I install an Ethernet panel mount cable?

Prepare the panel to the approved drawing, fit the housing with the specified hardware, and support the internal lead. Check plug access, bend space, and clearance from sharp edges or moving parts. Verify the completed connection using the agreed acceptance procedure.

How can the sample and order review support my enclosure project?

We can review the panel interface, plug direction, and cable length as one assembly requirement. A sample and approved drawing help align mechanical fit with the production order. Include the required electrical documentation rather than relying on a broad quality claim.

How do I specify a cable for my enclosure?

Send the panel drawing, equipment port photo, plug direction, length, and quantity. Add the target speed, any PoE load, and environmental requirements. Confirm the selected model drawing before machining the panel or ordering the full batch.

Integrating an RJ45 Panel Port Without Creating Rework

A panel-mounted network connection is part of the enclosure design, not just a cable added at the end. The socket’s position affects access to external plugs, internal routing, and serviceability. Reviewing those details before the panel is made can prevent an otherwise suitable cable assembly from becoming a fit problem.

Define which side the user will access

Start with the intended service interface. Identify where the external lead will be connected, how often it may be unplugged, and whether a technician can reach the latch. Check door movement, nearby connectors, and any protective cover in the assembled product.

On the inside, mark the route from the panel socket to the equipment port. Include enough clearance for the connector body and a supported cable bend. Avoid choosing the shortest lead if it leaves the internal plug under tension or makes service access difficult.

Release a drawing, not a generic hole size

The BC-DAJ011 photographs show a female housing with mounting ears. The panel opening and fixing holes must match the selected version. A generic round-hole dimension or an unrelated threaded-connector specification is not a substitute for that drawing.

Confirm panel thickness, hole spacing, tolerances, and the fastener arrangement. Ask whether the intended screw and tool can be used after adjacent parts are installed. If the enclosure is already manufactured, send its drawing and photographs so the available space can be reviewed before sampling.

Choose the cable-end angle from the actual port

The straight and angled variants change the male-plug exit near the internal equipment. Take a photograph with the latch position visible and mark the desired direction. This is especially useful when ports are upside down or mounted vertically.

Check the installed geometry, not only the loose cable. A connector may fit into the socket yet direct the lead toward a cover or block an adjacent port. A fit sample in the intended enclosure gives a more useful answer than selecting “left” or “up” without a viewing reference.

Keep mechanical and electrical acceptance separate

A securely mounted socket does not establish the Ethernet performance of the complete connection. Identify the target speed, equipment interface, external cable, and other channel components. Agree on the required documentation for the assembly and any complete-system evaluation.

For PoE, state the source and device load along with the conductor construction and length. A slim cable or metal socket trim should not be used as evidence of a particular power capability. Similarly, a mounting-ear housing does not establish a waterproof or vibration rating.

Plan support and maintenance access

Support the internal lead so routine handling does not pull directly on the housing or terminations. Maintain the specified bend limits and keep cable routes clear of sharp edges and moving parts. The installation team should be able to replace the assembly without guessing how it was originally routed.

If the environment involves moisture, unusual vibration, or other demanding conditions, identify the required system rating before selecting the assembly. These standard pictured versions are not presented as IP-rated connectors. A protected installation requires its own design review.

Turn the approved sample into a purchasing record

Record the model, plug direction, finished length, panel drawing revision, cable construction, and label requirements. Include any required inspection report and packaging plan. That record helps keep repeat batches consistent even when the enclosure is built in stages.

For the first inquiry, send the panel and port views, target application, quantity, and delivery requirement. We can discuss the proposed configuration and sample so the quotation reflects both the physical integration and the network connection.

Send your panel integration requirements for a quotation for an Ethernet panel-mount cable.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top