Cat 5 Ethernet Cables for Legacy Replacements and OEM Builds
- BC-DAJ001 RJ45 male-to-male cable range for replacement and project-specific network connections.
- Six color options: black, green, blue, red, white, and yellow.
- Molded boots and latch protection help organize preterminated patching.
- Specify required category performance, length, conductor construction, and intended PoE use before ordering.
- For new network deployments, compare Cat 5e or higher against the project requirements rather than relying on the Cat 5 name alone.
Product Details
Replace an established network lead or standardize color-coded equipment connections with BC-DAJ001 RJ45 male-to-male cable assemblies. Choose black, green, blue, red, white, or yellow, then specify the required length, wiring, and network application for your replacement or OEM build.
Cat 5 is a legacy category designation, not a universal 100 Mbps speed limit. Four-pair Category 5 channels were suitable for 1000BASE-T, but an old label alone does not prove that an existing cable or a new assembly meets your required performance. For a new installation, compare our Cat 5e cables and Cat 6 options before specifying a legacy replacement.
Ordering Specification
| Selection item | What to specify |
|---|---|
| Family reference | BC-DAJ001 |
| Connector arrangement | RJ45-style 8P8C male plugs at both ends, as photographed |
| Color references | A black; B green; C blue; D red; E white; F yellow |
| Category requirement | State the required category, test limit, and acceptance evidence for the ordered assembly |
| Length | Request the installed length and tolerance; include feet or meters explicitly |
| Wiring | Specify straight-through or an equipment-specific mapping; confirm all required pairs |
| Conductors | Confirm copper construction, gauge, and solid or stranded design for the application |
| Jacket and environment | Specify indoor, outdoor, or building-installation requirements and supporting documentation |
| PoE | Provide the power application, length, and bundling conditions for review |
| OEM requirements | Discuss labels, packing, color identification, and quantity with the quotation |
Replace the Right Part, Not Just the Color
Black or blue jackets do not identify the electrical category. Check the existing jacket marking, connector condition, and equipment requirements. A matching color helps maintenance, but the replacement still needs the correct wiring and performance.
For an established 100 Mbps device, you can use a higher-category Ethernet cable without making the device faster. If the replacement is intended for Gigabit operation, verify the complete link rather than assuming a familiar plug guarantees the negotiated rate. The endpoints and every connection in the path matter.
Choose Construction for the Installation
A cord that is moved regularly and a fixed building cable have different mechanical requirements. Specify the conductor construction and compatible termination rather than assuming every assembled lead uses solid wire. Include contact finish, jacket flame classification, and environmental requirements in the order specification, with supporting documents for the supplied configuration.
For a camera or phone powered over the network, include the required PoE application in the inquiry. Cable resistance, connectors, length, and bundled heating affect the result. A general “PoE-ready” phrase does not define which power level or installation conditions have been assessed.
Plan the Whole Channel
The familiar 100 m copper Ethernet channel guideline includes the fixed cabling, connectors, and patch cords. In the conventional structured-cabling arrangement, the allowance is 90 m of permanent link plus 10 m of patch cords in total, not 10 m at each end. Different cord constructions and installation conditions can require a shorter allowance.
A 50 ft request is approximately 15.24 m; 200 ft is approximately 60.96 m. Those conversions help define the order, but neither length automatically guarantees a passing channel. Count the rest of the connection and select the assembly for its intended role.
Send a Clear RFQ
Tell us whether you need a legacy replacement, an equipment lead, or a new project specification. Include quantity by length and color, the required Ethernet rate, any PoE load, and the installation environment. If category verification or material declarations are required, identify the acceptance criteria before sample approval.
Request a configuration review and quote. We can discuss the right cable specification and packaging without treating every color or length as the same application.
Choose Your Cable Color
Choose the color reference that matches your labeling plan. Color identifies the assembly appearance, not a different Ethernet speed or power rating. Confirm length and electrical requirements with each order.

BC-DAJ001-A provides a black RJ45 lead for a consistent equipment or cabinet layout. Molded boots and latch guards support ordinary cable handling. Specify the required length, wiring, and category acceptance, then check the boot clearance at both ports before approving the assembly.

BC-DAJ001-B provides a green jacket for your own network identification scheme. Use it alongside labels to distinguish a designated equipment group or route. Confirm the conductor construction, length, and required performance separately; green does not imply a particular protocol or power capability.

BC-DAJ001-C is the blue version of the RJ45 assembly shown in the photo. It can support an organized color plan across desks or patching areas. Include the required quantity by length in your inquiry, and verify the chosen cable specification against the intended network connection.

BC-DAJ001-D uses a red jacket to make a designated connection easy to identify during maintenance. Define the color meaning in your port schedule and pair it with readable labels. Include quantities by length and the required wiring so replacement leads follow the same documented specification.

BC-DAJ001-E is the white option for equipment layouts that prefer a light-colored lead. Check boot clearance and routing at both ports before ordering. Request the required length and category, and label connections where appearance alone would make them difficult to identify.

BC-DAJ001-F uses a yellow jacket for clear visual distinction in a documented cabling plan. Pair the color with port labels rather than relying on it as the only identifier. Confirm the final length, wiring, and any power-delivery requirements before approving the assembly.
Check the Boot as Well as the Plug
Molded boots and raised latch guards help protect the plug latch during ordinary cable handling. Check the available space around recessed ports and crowded patch panels so the boot fits and the release remains accessible after installation.
Specify wiring, conductor construction, length, and the required category acceptance alongside the chosen color. Keep the approved configuration and identification with the purchase reference for consistent replacement and repeat orders.

No. 1000BASE-T was designed for suitable four-pair Category 5 channels. That does not certify an individual old cable or this assembly at every length. For new procurement, specify the required category and verify the complete connection instead of relying on the name.
Normally, a suitable higher-category Ethernet cable can connect compatible Ethernet ports, but it will not increase the device’s speed capability. Confirm the connector, wiring, and installation requirements; proprietary RJ45 connections require separate review.
No. A 200 ft length is about 60.96 m, but performance depends on cord construction and the complete channel. Include other leads, outlets, and connectors, and verify the applicable length allowance and test requirements.
Provide the PoE application, power requirements, length, and bundling conditions. The category name and jacket color are not sufficient to establish PoE suitability. Confirm conductor and connector requirements for the selected assembly.
Do not infer outdoor resistance or a building flame classification from a PVC jacket or product photo. Specify the environment and required documented rating. Choose an appropriately rated assembly rather than treating an ordinary equipment cord as suitable for every installation.
Follow the equipment documentation. Many Ethernet ports support automatic pair crossover, but that should not be assumed for every legacy device. State the required mapping, especially when replacing a lead used with older or proprietary equipment.
Send the required length, units and tolerance, quantity by color, label content, and packaging format. The quotation should confirm the final construction, availability, minimum quantity, and delivery schedule; custom markings should not imply unverified certification.
Check the agreed dimensions, color, wiring, plug engagement, and installation fit. Verify performance using an appropriate method for the specified category and application. A basic continuity check or a visible link light alone does not constitute category certification.
Specifying a Replacement for an Established Ethernet Link
An Ethernet replacement order is easier to define when it records the complete connection and the role of the lead. Check the required rate, existing wiring, and installation conditions, then choose a like-for-like configuration or an updated category specification. This gives purchasing a clear reference for samples and repeat orders.
Start with the Endpoint Requirement
Record the switch and device port capabilities and the speed the application requires. A printer with a 100 Mbps port will not become a Gigabit device just by swapping the cable. Conversely, a Gigabit-capable link that negotiates only 100 Mbps may require investigation of all four pairs, terminations, and endpoint settings rather than a jacket-color change.
Check whether the lead is a standard Ethernet patch cable or an equipment-specific cable that happens to use an RJ45-style plug. Connector shape alone does not distinguish Ethernet from a proprietary control or console connection.
Identify What Is Being Replaced
Read the jacket marking and photograph both plugs. Note the existing length, cable reference, and whether there are couplers, wall outlets, or a patch panel in the path. When the original specification is missing, state the required outcome instead of asking a supplier to reproduce an unknown cable exactly.
For a new cabling plan, review the equipment’s required category and expected service life. Our Ethernet cable range separates category choices from special forms such as panel-mount and outdoor assemblies. Choose the form and performance together.
Do Not Confuse Continuity with Qualification
A basic wire-map check can find some opens, shorts, and miswiring, but it does not certify category performance. A link light also does not establish that a cable has the required margin under load. Agree on the appropriate verification method for the product and the installed channel.
If testing reports are part of procurement, specify the test limit, reference configuration, and identification required on the report. Avoid requesting a generic “passed” result with no connection to the length and assembly being purchased.
Keep Color Coding Practical
Use colors to support your own documented identification system. For example, you may reserve one color for a department or equipment group, but that convention is local to your organization. A red cord is not inherently a safety-rated link, and a green cord is not automatically suitable for a particular PoE device.
Combine color with readable labels and an accurate port schedule. This lets a technician replace the correct lead even in poor lighting or when several similar cables share a tray.
Approve the Replacement in Its Intended Role
Before approving the sample, check plug engagement, latch access, boot clearance, and the cable route. Avoid tension at the ports and sharp crushing by furniture, doors, or ties. For a power-carrying link, assess the intended PoE equipment and installation conditions as part of the review.
Keep the approved construction, length, wiring, and identification with the purchase reference. That record is more useful for repeat orders than an isolated photograph. Send your existing cable details and replacement requirements so we can define an assembly rather than an uncertain match.