Sealed Cable Configurations for Defined Environments
BespokeCable manufactures custom waterproof cable assemblies for equipment exposed to rain, spray, temporary immersion, washdown, or other defined liquid conditions. Waterproof is not a complete technical requirement. Specify the assembly by its mating interfaces, electrical function, cable construction, sealing boundary, installation state, and test method.
The current range includes M6, M8, M12, M15, M16, M17, M18, M19, M20, and M23-labeled circular configurations; T- and Y-shaped branches; waterproof USB-C and other USB assemblies; and waterproof DC power cables. Nominal size names do not prove a common thread, keying, pinout, or rating. We therefore keep each product as its own live configuration and quote from exact drawings or verified samples.
Provide the connector and mate, contact count, pin map, voltage, current or signal, cable length, jacket exposure, mating state, panel interface, and required ingress test. We can then review overmolding, seals, potting, strain relief, branch geometry, materials, inspection, and packaging for the approved assembly.
Send your connector drawing and environmental test requirements.
Waterproof Cable Configurations

This M6-labeled waterproof cable represents a compact sealed configuration. Confirm the exact connector standard, thread or coupling, contacts, mating part, pin map, cable diameter, and required ingress test. The size name and image do not establish interchangeability, an IP rating, or suitability while unmated.

Specify this M8-labeled assembly by exact mating interface, keying, pole count, electrical load, cable construction, and sealing test. State whether the connector is molded, field-attachable, or panel-mounted, and identify the exposed boundary. A connector component rating is not automatically a finished-cable rating.

This M12-labeled waterproof cable is a representative circular configuration. Provide the exact coding or keying, pole count, mating part, pin assignment, electrical and signal requirements, jacket, length, and test conditions. If installed through a panel, include the receptacle, cutout, and seal in the boundary review.

This M15-labeled cable is retained as a distinct live size configuration. Confirm the actual connector drawing, coupling, positions, cable entry, and mating components because M15 wording alone is not a complete interface standard. Define temperature, liquid exposure, installation movement, and ingress acceptance criteria.

This M16-labeled waterproof configuration requires the exact connector and mating details, not only a nominal shell size. State the contacts, pin map, electrical load, cable diameter, exit direction, sealing boundary, and required test method. Include panel hardware or caps when they form part of the protected connection.

Review this M17-labeled waterproof cable against a dimensioned connector drawing or verified part numbers. Provide the contact arrangement, wiring, cable material, length, coupling, and environmental exposure. Specify whether the ingress condition applies only when mated and how the complete assembly will be tested.

This M18-labeled assembly represents another live circular size. Confirm the connector family, shell or thread dimensions, contacts, mate, pinout, electrical requirements, and cable entry. Do not assume that a visually similar M18 product shares keying, sealing, or ratings with another supplier’s configuration.

This M19-labeled waterproof cable should match the equipment interface and approved sample. Define connector geometry, contacts, pin assignment, jacket, length, strain relief, exposure, and test criteria. If the interface is proprietary, provide the mating component or equipment drawing for fit review.

This M20-labeled configuration is a separate live product card. Quote it from the exact connector and mating drawing, pole count, circuit functions, cable construction, and environmental conditions. The project should also define caps, panel seals, and the mated or unmated state used for ingress acceptance.

This M23-labeled waterproof cable represents a larger circular configuration in the current range. Confirm shell and coupling dimensions, contacts, wire, load, keying, panel or cable mount, length, and exposure. Include installation clearance and torque or locking instructions only when supported by the selected connector documentation.

This T-shaped waterproof cable provides a three-way physical layout. Define which branch is the input, each output, branch lengths, connector orientation, circuit mapping, electrical load, and sealing boundary. A molded T geometry can reduce field junctions, but it must fit the equipment and test plan.

This Y-shaped waterproof cable splits or combines two branches from a common leg. Provide the complete wiring map, branch dimensions, connector genders, load allocation, cable construction, overmold geometry, and ingress test. The Y shape alone does not determine whether circuits are paralleled, separated, or signal-specific.

Specify this waterproof USB-C cable by the required USB functions, power role, plug or receptacle arrangement, cable length, enclosure interface, and sealing method. A protective shell or overmold can change mating clearance. Do not claim a data rate, power level, or IP performance until the exact construction is verified.

This waterproof USB cable covers a sealed USB interface, and the connector type must be identified. State USB-A, USB-B, Micro-USB, or another format; plug genders; required functions; cable length; panel or inline seal; and test conditions. The waterproof feature must be assessed together with the mating interface.

This waterproof DC power cable is intended for a defined low-voltage power connection. Confirm connector dimensions and polarity, voltage, continuous current, wire size, length, fuse or protection strategy, coupling, cable material, and ingress test. Similar barrel or circular plugs can have incompatible sizes and wiring.
Define the Complete Sealing Boundary
Identify every place where water could enter: the cable jacket, overmold, connector interface, rear seal, panel cutout, splice, and branch. State which mating components, caps, and enclosure features are included. Testing only one component does not prove the assembled installation.


Specify Exposure as a Test Condition
State rain, spray, temporary immersion, continuous immersion, or washdown; then provide the relevant method, depth or pressure, duration, temperature, and mating state. Tie an IP code to the exact construction and test evidence, rather than applying it across the whole product category.
Match Materials to Liquids and Movement
List water, oils, cleaners, salt, UV, temperature, abrasion, and flexing conditions. Then review jacket, seal, potting, and overmold materials for actual exposure. No single waterproof material is automatically suitable for every chemical, outdoor, or moving application.


Protect Electrical Performance as Well as the Seal
Define voltage, current, signal type, wire, shield, and grounding requirements. A connection can remain dry yet still be electrically unsuitable because of contact, conductor, length, or signal constraints. The RFQ should keep electrical and environmental acceptance criteria together.
Validate the Approved Assembly and Installation
Sample review should include mating, dimensions, wiring, orientation, strain relief, and the agreed ingress test. Panel hardware, caps, and installation instructions must match the test setup. Freeze the drawing, materials, and test plan before repeat orders, then align inspection with the controlled quality process.

Not automatically. The final result also depends on the cable entry, overmold or rear seal, mating part, panel interface, assembly process, and test setup. Request evidence for the exact complete configuration and state whether it is tested mated, unmated, or capped.
Only if the specified interface provides protection in that state, often with an approved cap or separate sealing feature. Many connections rely on the mate to complete the seal. Define the disconnected exposure and include the cap in validation.
Provide the exact connector drawing or part number, mating part, coding or keying, gender, contact count, pin map, cable, length, exposure, and ingress test. A nominal M size alone does not define the complete interface or performance.
It may be possible when the circuit map, conductor construction, separation, shield termination, and connector ratings support the design. Supply the complete wiring table and electrical requirements; do not infer the branch connections from the molded shape.
Define and verify the required USB data, power, and role functions for the exact cable and sealing interface. A waterproof shell does not, by itself, establish protocol generation, power level, or cable length suitability.
Evaluate caps once you know the exact connector, required unmated protection, attachment method, material, and operating procedure. Include the cap in the drawing, packaging, and environmental validation if it is necessary to maintain the seal.
Name the liquid, concentration, temperature, exposure time, and cleaning or rinse cycle. Waterproofing and chemical compatibility are separate requirements, so review the jacket, seals, contacts, and hardware against the actual exposure.
A repair may alter the original sealing system and should not be assumed to restore the validated ingress performance. Define whether field repair is permitted and what rework, inspection, and retesting are required; replacement may be safer for critical installations.
Use the intended mate, panel hardware, caps, and installation. Verify wiring and dimensions first, then perform the agreed ingress method and acceptance checks. Record the sample construction and test setup so that later production can be compared with it.
Freeze the approved connector, cable, seals, potting, or overmold materials and tooling revision. Review any proposed substitute for fit, electrical performance, chemical compatibility, and the need for renewed ingress validation before use.
How to Specify a Waterproof Cable Assembly
A waterproof cable succeeds only when you define and validate the complete connection. A molded connector may look sealed, yet the result still depends on its mate, cable entry, panel interface, material compatibility, installation, and test conditions. Buyers can avoid ambiguous IP claims by converting the operating environment into measurable requirements.
1. Map Every Potential Ingress Path
Identify the cable jacket, connector face, rear seal, overmold, splice, branch, and panel opening. Show which parts are supplied and which belong to the customer equipment. If a protective cap is required while disconnected, include it in the specification and sample test.
2. Define the Mated and Unmated Conditions
Many sealed connections rely on compression between mating parts. State whether protection is required while mated, unmated, capped, or during connection. Include the expected frequency of service and the risk of dirt, damaged seals, or water trapped at the interface.
3. State the Required Ingress Test
Provide the rating or other method, test depth or pressure, duration, water temperature, and acceptance criteria. If the assembly is installed through a panel, test the relevant panel arrangement. Do not transfer a component rating to a different cable, overmold, or enclosure without validating the final configuration.
4. Identify the Connector Precisely
Nominal labels such as M8, M12, or M20 are not enough to establish the complete interface. Provide the connector standard or drawing, coding, gender, contacts, keying, coupling, mating part, and panel geometry. For proprietary equipment, a sample can support fit review, but the approved design should still be documented.
5. Define Electrical and Signal Requirements
State voltage, continuous current, polarity, signal or protocol, conductor size, shielding, and grounding. For USB or data interfaces, define required functions and system constraints without assuming that sealing hardware preserves every optional performance level. Cable length and construction remain part of signal and power validation.
6. Review Materials Against the Environment
List temperature, UV, saltwater, oils, fuels, cleaners, disinfectants, abrasion, and flexing. Select jacket, seal, adhesive, potting, and overmold materials for the actual exposure. Waterproof does not automatically mean chemical resistance, cold-flex, UV resistance, or suitability for permanent submersion.
7. Control Branches and Molded Geometry
For T- or Y-shaped assemblies, define the circuit map, branch dimensions, connector orientation, and overmold envelope. Confirm how loads are divided and whether signals remain separate. Include mounting and bend clearances so the branch body can be installed without stressing the cable exits.
8. Establish Sample Validation
Inspect connector fit, pinout, polarity, dimensions, orientation, seal surfaces, and workmanship before environmental testing. Use the complete approved mating setup and record the method and outcome. If the sample changes in cable, connector, seal, overmold, or process, determine whether the ingress test must be repeated.
9. Prepare for Production and Field Use
Freeze controlled materials, dimensions, tooling revision, test plan, and packaging. Protect sealing faces during shipment and define any cap, torque, cleaning, or installation instructions the user needs. Packaging should avoid deformation or contamination that could undermine a tested seal.
Waterproof Cable RFQ Checklist
| Area | What to provide |
|---|---|
| Interface | Connector drawing, mate, coding, contacts, coupling and panel details |
| Electrical | Pin map, voltage, current, signal, wire, shield and grounding |
| Environment | Water exposure, temperature, UV, chemicals, abrasion and flexing |
| Ingress test | Method, depth or pressure, duration, mating state and acceptance |
| Mechanical | Length, branches, orientation, overmold envelope and routing |
| Commercial | Samples, production quantity, packaging and delivery |