Custom D-Sub Connectors for PCB Integration

Select standard or high density, male or female, and straight or right-angle orientation—then confirm the exact shell, positions, footprint, and mate.

DB and High-Density D-Sub Connector Configurations

BespokeCable supplies D-Sub connector configurations for OEM boards, control equipment, and long-life systems. The current live range distinguishes standard-density DB and high-density HD layouts, female and male contacts, and 90-degree or 180-degree PCB orientations. These differences change the mating interface, board footprint, and enclosure layout, so each card remains a separate configuration.

A D-Sub inquiry should state shell size, exact position count, contact gender, density, board orientation, termination, mounting hardware, mating connector, and panel relationship. Informal names can be ambiguous: a standard-density 15-position connector and a high-density 15-position connector use different row arrangements and do not mate.

Also define contact and shell requirements, board thickness, footprint, connector height, retention, service access, and order-specific evidence. Pinout and protocol are equipment decisions; the same D-Sub shell may be used for different circuits. Confirm every assignment in the product drawing rather than inheriting a generic serial, video, or control pinout.

Send the mating connector and PCB drawing for review.

D-Sub PCB Connector Configurations

D-Sub DB Female 90 Degree Connector for PCB
D-Sub DB Female 90 Degree Connector for PCB

This standard-density DB configuration combines female contacts with a 90-degree PCB orientation. Confirm shell size, position count, board footprint, mounting hardware, mating plug, rear clearance, and contact specifications. Check the right-angle geometry against the enclosure opening and insertion direction.

D-Sub DB Female 180 Degree Connector for PCB
D-Sub DB Female 180 Degree Connector for PCB

This standard-density DB female configuration uses a 180-degree, straight PCB orientation. Provide the shell and position count, board layout, mounting style, stack height, mating, and panel relationship. Straight entry needs adequate depth behind the connector and alignment between the board and the external mating path.

D-Sub DB Male 90 Degree Connector for PCB
D-Sub DB Male 90 Degree Connector for PCB

This DB male right-angle PCB configuration presents pins at the mating face and turns the termination toward the board. Confirm shell size, positions, footprint, mounting hardware, mating receptacle, height, and latch or screw access. Define gender by the contacts, not just the shell appearance.

D-Sub DB Male 180 Degree Connector for PCB
D-Sub DB Male 180 Degree Connector for PCB

This DB male straight PCB configuration is intended for an inline board relationship. Specify shell and position count, contact layout, board thickness and footprint, mounting posts, mating, panel offset, and available depth. Validate pin protection and assembly handling for exposed male contacts.

D-Sub HD Female 90 Degree Connector for PCB
D-Sub HD Female 90 Degree Connector for PCB

This high-density HD female right-angle PCB configuration uses a denser contact arrangement than standard DB layouts. Confirm the exact position count, shell, footprint, row spacing, mating, mounting hardware, and enclosure clearance. A high-density 15-position interface is not mechanically identical to a standard 15-position D-Sub.

D-Sub HD Female 180 Degree Connector for PCB
D-Sub HD Female 180 Degree Connector for PCB

This HD female straight PCB configuration requires an exact high-density layout and board pattern. Provide the position count, shell size, mating plug, termination dimensions, mounting method, and panel geometry. Check connector depth, alignment, and service access in the intended enclosure.

D-Sub HD Male 90 Degree Connector for PCB
D-Sub HD Male 90 Degree Connector for PCB

This HD male right-angle PCB configuration combines high-density pin contacts with a board-turn orientation. Confirm positions, shell, footprint, row layout, mating hardware, connector height, and insertion direction. The approved drawing should control pin dimensions and board location.

D-Sub HD Male 180 Degree Connector for PCB
D-Sub HD Male 180 Degree Connector for PCB

This HD male straight PCB configuration is retained for an inline high-density board interface. Specify the position count, shell size, mating receptacle, board footprint, mounting hardware, panel offset, and available depth. Review protection of the male contacts during assembly and shipment.

Choose Standard or High Density First

Confirm the row arrangement, shell size, and exact position count. Standard and high-density versions can share familiar names while remaining mechanically incompatible. Use the mating connector drawing and contact layout as the primary reference, not only DB or HD shorthand.

RS-232 Serial Communication Application
VGA Video Interface Standard

Define Gender by Contacts

Male connectors have pin contacts, and female connectors have socket contacts, regardless of the surrounding shell or equipment location. State the gender of both the new connector and its mate. This avoids errors caused by describing the equipment side from the viewing direction.

Match Orientation to the Board and Panel

A 90-degree connector turns the mating axis relative to the PCB, while a 180-degree or straight version stays in line. Confirm the footprint, connector height, insertion path, panel offset, and screw access in the actual enclosure before freezing the part.

Industrial Control and Automation
Connector Structure and Shielding

Control Mounting and Mechanical Hardware

Specify board locks, mounting holes, threaded inserts, screws, brackets, or panel hardware and their dimensions. Hardware variants can affect footprint and alignment even when the mating face is unchanged. Include assembly and service loads in the mechanical review.

Validate the Connector and Pin Assignment Together

Check fit with the real mate, PCB alignment, retention, and termination quality. The equipment drawing should separately control the circuit assignment, shell bonding, and any shielding strategy. Use an approved first article and documented inspection criteria for repeat orders.

Installation and Termination Methods
What is the difference between DB and HD D-Sub connectors?

They use different contact densities and row arrangements. State the exact shell and position count because similar application names do not make the mating faces interchangeable. Confirm the actual mate and drawing before selection.

How is D-Sub connector gender identified?

Pins indicate a male connector, and sockets indicate a female connector. Identify gender by the mating-face contacts, not by the equipment location or the shell viewed from behind.

Does 90 degree mean the same thing for every supplier?

It normally indicates a right-angle relationship between the mating axis and the PCB, but drawings and viewing conventions can vary. Confirm the mating direction, board side, connector height, and footprint from the exact part drawing.

Can a straight connector replace a right-angle connector?

Not without redesigning the board or enclosure. The footprint, insertion direction, panel alignment, height, and rear clearance differ. Review the entire mechanical stack before approving a change.

Can one D-Sub connector carry power and signals?

A custom equipment design may use different circuits, but you must evaluate contact, wire, spacing, grounding, safety, and system requirements. Provide the exact pin map and electrical loads; do not infer suitability from the connector shell.

Can mounting screws or threaded inserts be customized?

Review hardware options against the mating connector, panel thickness, board layout, and service method. Specify the thread, length, location, and whether the hardware is captive or separately packed.

What is needed to replace an obsolete D-Sub part?

Provide the original manufacturer part number, drawing, mate, PCB footprint, panel dimensions, hardware, and required evidence. A visually similar connector should be sampled and checked on the actual board and enclosure before release.

Can selective contact plating be specified?

Yes, when you define the contact area, material, thickness, and evidence requirements. Confirm the exact part data and avoid using a generic gold-plated description that does not identify where or how much plating is applied.

How should D-Sub connectors be packaged?

Packaging depends on the connector and assembly process. State tray, tube, bulk, or other needs; orientation; pin protection; lot labels; and quantity per pack. Male contacts may need additional protection from bending during handling.

Are these cards product detail pages?

No verified public child detail pages were found for these live configurations. Each card is retained as a real supplied configuration and uses the inquiry popup; the Product Link remains blank until a genuine supporting destination exists.

How to Specify a D-Sub PCB Connector

D-Sub selection is a sequence of mechanical decisions. The buyer first identifies density and contact layout, then gender, orientation, termination, and hardware. Only after you mechanically define the connector should you confirm the equipment pinout and channel requirements. This prevents familiar labels such as DB15, HD15, or serial connector from hiding an incompatible interface.

1. Record the Exact Mating Connector

Provide the mating part number, drawing, or verified sample. Record shell size, contact count, row arrangement, gender, and key geometry. If the interface is mounted behind a panel, include the cutout and distance between the board and panel face.

2. Distinguish DB and HD Layouts

Standard-density and high-density connectors use different contact spacing and row arrangements. State the exact number of positions and density rather than relying on a colloquial application name. A 15-position standard connector is not the same physical interface as a 15-position high-density connector.

3. Define Male and Female Correctly

Gender follows the contacts: pins are male, and sockets are female. Photograph the mating face and identify whether the new part is on the board, cable, or panel. This avoids the common mistake of naming gender from the opposite side or from the device rather than the connector.

4. Choose 90-Degree or Straight Orientation

Right-angle configurations place the mating axis parallel to the board, while straight configurations place it perpendicular. Verify connector height, rear depth, keep-out zones, insertion path, and screw access. Orientation also changes the PCB footprint and assembly sequence.

5. Specify Board and Panel Hardware

Provide the approved footprint, hole pattern, board thickness, mounting posts, board locks, threaded inserts, and panel hardware. Check the distance from the mating face to the board and panel. Hardware should support alignment and retention without forcing the solder joints to carry mechanical load.

6. Define Contacts, Shell and Termination

State any controlled contact material, plating, shell finish, insulation, and temperature requirements by exact part or data. Identify through-hole or other termination and the intended assembly process. Avoid broad gold-plated or industrial-grade claims without a defined surface, thickness, and evidence.

7. Control the Equipment Pinout

D-Sub is a connector form, not one universal protocol. Supply the pin map for serial, control, video, mixed-signal, or proprietary use and define shell and shield connections. Never copy a standard-looking pinout unless the equipment documentation confirms it.

8. Approve the First Article

Check mating, keying, alignment, insertion, hardware, board fit, and panel access. Inspect termination and verify the equipment pin map. If the connector source or hardware changes, compare the full drawing and evidence before approving the alternate.

D-Sub RFQ Checklist

ItemRequired detail
LayoutDB or HD, shell size, position count, and rows
GenderMale pins or female sockets and mating part
Orientation90-degree or straight and mating direction
PCBFootprint, board thickness, hole pattern, and keep-outs
HardwareBoard locks, inserts, screws, brackets, and panel dimensions
ElectricalPin map, shell bond, shield, and application requirements
CommercialSamples, quantity, packaging, and delivery

Return to the connector collection for other families, or send the mate and board layout for a D-Sub review.

Get an Instant Quote Now
Quick Quote

Discuss Your Connectivity Project

Scroll to Top