DB and High-Density D-Sub Connector Configurations
BespokeCable supplies D-Sub connector configurations for OEM boards, control equipment, and long-life systems. The current live range distinguishes standard-density DB and high-density HD layouts, female and male contacts, and 90-degree or 180-degree PCB orientations. These differences change the mating interface, board footprint, and enclosure layout, so each card remains a separate configuration.
A D-Sub inquiry should state shell size, exact position count, contact gender, density, board orientation, termination, mounting hardware, mating connector, and panel relationship. Informal names can be ambiguous: a standard-density 15-position connector and a high-density 15-position connector use different row arrangements and do not mate.
Also define contact and shell requirements, board thickness, footprint, connector height, retention, service access, and order-specific evidence. Pinout and protocol are equipment decisions; the same D-Sub shell may be used for different circuits. Confirm every assignment in the product drawing rather than inheriting a generic serial, video, or control pinout.
D-Sub PCB Connector Configurations

This standard-density DB configuration combines female contacts with a 90-degree PCB orientation. Confirm shell size, position count, board footprint, mounting hardware, mating plug, rear clearance, and contact specifications. Check the right-angle geometry against the enclosure opening and insertion direction.

This standard-density DB female configuration uses a 180-degree, straight PCB orientation. Provide the shell and position count, board layout, mounting style, stack height, mating, and panel relationship. Straight entry needs adequate depth behind the connector and alignment between the board and the external mating path.

This DB male right-angle PCB configuration presents pins at the mating face and turns the termination toward the board. Confirm shell size, positions, footprint, mounting hardware, mating receptacle, height, and latch or screw access. Define gender by the contacts, not just the shell appearance.

This DB male straight PCB configuration is intended for an inline board relationship. Specify shell and position count, contact layout, board thickness and footprint, mounting posts, mating, panel offset, and available depth. Validate pin protection and assembly handling for exposed male contacts.

This high-density HD female right-angle PCB configuration uses a denser contact arrangement than standard DB layouts. Confirm the exact position count, shell, footprint, row spacing, mating, mounting hardware, and enclosure clearance. A high-density 15-position interface is not mechanically identical to a standard 15-position D-Sub.

This HD female straight PCB configuration requires an exact high-density layout and board pattern. Provide the position count, shell size, mating plug, termination dimensions, mounting method, and panel geometry. Check connector depth, alignment, and service access in the intended enclosure.

This HD male right-angle PCB configuration combines high-density pin contacts with a board-turn orientation. Confirm positions, shell, footprint, row layout, mating hardware, connector height, and insertion direction. The approved drawing should control pin dimensions and board location.

This HD male straight PCB configuration is retained for an inline high-density board interface. Specify the position count, shell size, mating receptacle, board footprint, mounting hardware, panel offset, and available depth. Review protection of the male contacts during assembly and shipment.
Choose Standard or High Density First
Confirm the row arrangement, shell size, and exact position count. Standard and high-density versions can share familiar names while remaining mechanically incompatible. Use the mating connector drawing and contact layout as the primary reference, not only DB or HD shorthand.


Define Gender by Contacts
Male connectors have pin contacts, and female connectors have socket contacts, regardless of the surrounding shell or equipment location. State the gender of both the new connector and its mate. This avoids errors caused by describing the equipment side from the viewing direction.
Match Orientation to the Board and Panel
A 90-degree connector turns the mating axis relative to the PCB, while a 180-degree or straight version stays in line. Confirm the footprint, connector height, insertion path, panel offset, and screw access in the actual enclosure before freezing the part.


Control Mounting and Mechanical Hardware
Specify board locks, mounting holes, threaded inserts, screws, brackets, or panel hardware and their dimensions. Hardware variants can affect footprint and alignment even when the mating face is unchanged. Include assembly and service loads in the mechanical review.
Validate the Connector and Pin Assignment Together
Check fit with the real mate, PCB alignment, retention, and termination quality. The equipment drawing should separately control the circuit assignment, shell bonding, and any shielding strategy. Use an approved first article and documented inspection criteria for repeat orders.

They use different contact densities and row arrangements. State the exact shell and position count because similar application names do not make the mating faces interchangeable. Confirm the actual mate and drawing before selection.
Pins indicate a male connector, and sockets indicate a female connector. Identify gender by the mating-face contacts, not by the equipment location or the shell viewed from behind.
It normally indicates a right-angle relationship between the mating axis and the PCB, but drawings and viewing conventions can vary. Confirm the mating direction, board side, connector height, and footprint from the exact part drawing.
Not without redesigning the board or enclosure. The footprint, insertion direction, panel alignment, height, and rear clearance differ. Review the entire mechanical stack before approving a change.
A custom equipment design may use different circuits, but you must evaluate contact, wire, spacing, grounding, safety, and system requirements. Provide the exact pin map and electrical loads; do not infer suitability from the connector shell.
Review hardware options against the mating connector, panel thickness, board layout, and service method. Specify the thread, length, location, and whether the hardware is captive or separately packed.
Provide the original manufacturer part number, drawing, mate, PCB footprint, panel dimensions, hardware, and required evidence. A visually similar connector should be sampled and checked on the actual board and enclosure before release.
Yes, when you define the contact area, material, thickness, and evidence requirements. Confirm the exact part data and avoid using a generic gold-plated description that does not identify where or how much plating is applied.
Packaging depends on the connector and assembly process. State tray, tube, bulk, or other needs; orientation; pin protection; lot labels; and quantity per pack. Male contacts may need additional protection from bending during handling.
No verified public child detail pages were found for these live configurations. Each card is retained as a real supplied configuration and uses the inquiry popup; the Product Link remains blank until a genuine supporting destination exists.
How to Specify a D-Sub PCB Connector
D-Sub selection is a sequence of mechanical decisions. The buyer first identifies density and contact layout, then gender, orientation, termination, and hardware. Only after you mechanically define the connector should you confirm the equipment pinout and channel requirements. This prevents familiar labels such as DB15, HD15, or serial connector from hiding an incompatible interface.
1. Record the Exact Mating Connector
Provide the mating part number, drawing, or verified sample. Record shell size, contact count, row arrangement, gender, and key geometry. If the interface is mounted behind a panel, include the cutout and distance between the board and panel face.
2. Distinguish DB and HD Layouts
Standard-density and high-density connectors use different contact spacing and row arrangements. State the exact number of positions and density rather than relying on a colloquial application name. A 15-position standard connector is not the same physical interface as a 15-position high-density connector.
3. Define Male and Female Correctly
Gender follows the contacts: pins are male, and sockets are female. Photograph the mating face and identify whether the new part is on the board, cable, or panel. This avoids the common mistake of naming gender from the opposite side or from the device rather than the connector.
4. Choose 90-Degree or Straight Orientation
Right-angle configurations place the mating axis parallel to the board, while straight configurations place it perpendicular. Verify connector height, rear depth, keep-out zones, insertion path, and screw access. Orientation also changes the PCB footprint and assembly sequence.
5. Specify Board and Panel Hardware
Provide the approved footprint, hole pattern, board thickness, mounting posts, board locks, threaded inserts, and panel hardware. Check the distance from the mating face to the board and panel. Hardware should support alignment and retention without forcing the solder joints to carry mechanical load.
6. Define Contacts, Shell and Termination
State any controlled contact material, plating, shell finish, insulation, and temperature requirements by exact part or data. Identify through-hole or other termination and the intended assembly process. Avoid broad gold-plated or industrial-grade claims without a defined surface, thickness, and evidence.
7. Control the Equipment Pinout
D-Sub is a connector form, not one universal protocol. Supply the pin map for serial, control, video, mixed-signal, or proprietary use and define shell and shield connections. Never copy a standard-looking pinout unless the equipment documentation confirms it.
8. Approve the First Article
Check mating, keying, alignment, insertion, hardware, board fit, and panel access. Inspect termination and verify the equipment pin map. If the connector source or hardware changes, compare the full drawing and evidence before approving the alternate.
D-Sub RFQ Checklist
| Item | Required detail |
|---|---|
| Layout | DB or HD, shell size, position count, and rows |
| Gender | Male pins or female sockets and mating part |
| Orientation | 90-degree or straight and mating direction |
| PCB | Footprint, board thickness, hole pattern, and keep-outs |
| Hardware | Board locks, inserts, screws, brackets, and panel dimensions |
| Electrical | Pin map, shell bond, shield, and application requirements |
| Commercial | Samples, quantity, packaging, and delivery |
Return to the connector collection for other families, or send the mate and board layout for a D-Sub review.