x
Send Your Inquiry Today
Quick Quote
  • MDR Cables: Mini Delta Ribbon cables for SCSI and servo drive connections, available in multiple pin configurations.
  • MDR 14-Pin Cable: Mini Delta Ribbon cable with 14-pin connector for compact SCSI or servo applications.
  • MDR 20-Pin Cable: Mini Delta Ribbon cable with 20-pin connector for industrial control and data transmission.
  • MDR 26-Pin Cable: Mini Delta Ribbon cable with 26-pin connector for SCSI and machine vision interfaces.
  • MDR 36-Pin Cable: Mini Delta Ribbon cable with 36-pin connector for high-density SCSI connections.
  • MDR 50-Pin Cable: Mini Delta Ribbon cable with 50-pin connector for wide SCSI bus and servo systems.
  • MDR 68-Pin Cable: Mini Delta Ribbon cable with 68-pin connector for high-speed SCSI and servo drive links.
  • MDR 14-Pin Cable with Terminals: Pre-terminated 14-pin MDR cable with crimped terminals for easy field installation.
  • MDR 20-Pin Cable with Terminals: Pre-terminated 20-pin MDR cable with crimped terminals for secure connections.
  • MDR 26-Pin Cable with Terminals: Pre-terminated 26-pin MDR cable with crimped terminals for reliable signal integrity.
  • MDR 36-Pin Cable with Terminals: Pre-terminated 36-pin MDR cable with crimped terminals for industrial use.
  • MDR 50-Pin Cable with Terminals: Pre-terminated 50-pin MDR cable with crimped terminals for high-density wiring.
  • MDR 68-Pin Cable with Terminals: Pre-terminated 68-pin MDR cable with crimped terminals for complex SCSI setups.
  • SCSI Servo Connection Cable: MDR cable designed for servo drive communication in automation and motion control systems.
  • PVC Jacket: Flexible PVC outer sheath protects MDR cable conductors from abrasion and environmental stress.
  • Plug and Play: MDR cable requires no driver installation for immediate use with compatible SCSI and servo devices.
  • Pure Copper Crimp Terminal: High-conductivity copper crimp terminal ensures low resistance and reliable electrical contact.
  • MDR Connector Housing Dimension 1: Outer dimensions and mounting hole locations for MDR connector shell.
  • MDR Connector Housing Dimension 2: Side view and depth measurements for MDR connector housing assembly.
  • MDR Cable Application: Used in SCSI storage arrays, servo motor drives, CNC machines, and industrial automation systems.
  • MDR Cable Construction Diagram: Cross-section showing conductor gauge, insulation, shielding layers, and PVC jacket.
  • Gold-Plated MDR Connector: Corrosion-resistant gold plating on pins ensures stable signal transmission and long service life.
  • Terminal Installation Guide: Step-by-step illustration for crimping and inserting terminals into MDR connector housing.
  • MDR Cables: Mini Delta Ribbon cables for SCSI and servo drive connections, available in multiple pin configurations.
  • MDR 14-Pin Cable: Mini Delta Ribbon cable with 14-pin connector for compact SCSI or servo applications.
  • MDR 20-Pin Cable: Mini Delta Ribbon cable with 20-pin connector for industrial control and data transmission.
  • MDR 26-Pin Cable: Mini Delta Ribbon cable with 26-pin connector for SCSI and machine vision interfaces.
  • MDR 36-Pin Cable: Mini Delta Ribbon cable with 36-pin connector for high-density SCSI connections.
  • MDR 50-Pin Cable: Mini Delta Ribbon cable with 50-pin connector for wide SCSI bus and servo systems.
  • MDR 68-Pin Cable: Mini Delta Ribbon cable with 68-pin connector for high-speed SCSI and servo drive links.
  • MDR 14-Pin Cable with Terminals: Pre-terminated 14-pin MDR cable with crimped terminals for easy field installation.
  • MDR 20-Pin Cable with Terminals: Pre-terminated 20-pin MDR cable with crimped terminals for secure connections.
  • MDR 26-Pin Cable with Terminals: Pre-terminated 26-pin MDR cable with crimped terminals for reliable signal integrity.
  • MDR 36-Pin Cable with Terminals: Pre-terminated 36-pin MDR cable with crimped terminals for industrial use.
  • MDR 50-Pin Cable with Terminals: Pre-terminated 50-pin MDR cable with crimped terminals for high-density wiring.
  • MDR 68-Pin Cable with Terminals: Pre-terminated 68-pin MDR cable with crimped terminals for complex SCSI setups.
  • SCSI Servo Connection Cable: MDR cable designed for servo drive communication in automation and motion control systems.
  • PVC Jacket: Flexible PVC outer sheath protects MDR cable conductors from abrasion and environmental stress.
  • Plug and Play: MDR cable requires no driver installation for immediate use with compatible SCSI and servo devices.
  • Pure Copper Crimp Terminal: High-conductivity copper crimp terminal ensures low resistance and reliable electrical contact.
  • MDR Connector Housing Dimension 1: Outer dimensions and mounting hole locations for MDR connector shell.
  • MDR Connector Housing Dimension 2: Side view and depth measurements for MDR connector housing assembly.
  • MDR Cable Application: Used in SCSI storage arrays, servo motor drives, CNC machines, and industrial automation systems.
  • MDR Cable Construction Diagram: Cross-section showing conductor gauge, insulation, shielding layers, and PVC jacket.
  • Gold-Plated MDR Connector: Corrosion-resistant gold plating on pins ensures stable signal transmission and long service life.
  • Terminal Installation Guide: Step-by-step illustration for crimping and inserting terminals into MDR connector housing.
P/N: BC-CSC002

Custome MDR Cables

  • 14, 20, 26, 36, 50, and 68-position MDR options
  • MDR-to-MDR, MDR-to-IDC, and labeled flying-lead constructions
  • Wiring built from your device manual, schematic or approved sample
  • Shield and drain termination defined for the actual installation
  • Metal shell and latching hardware options subject to mating-port review
  • Custom branch lengths, conductor IDs, and panel-routing requirements
  • 100% continuity and short-circuit inspection
  • Prototype and repeat OEM production support

Custom MDR Cable Assemblies for Industrial Equipment

MDR connectors are found on many kinds of industrial hardware, from servo systems and I/O modules to imaging and proprietary control equipment. The plug may be recognizable, yet the electrical assignment behind it can be entirely device-specific. We therefore treat every MDR project as an interface-matching job, not a catalog-cable guess.

Tell us what the cable connects, the MDR position count, the second-end interface, and the required length. A drawing is ideal, but a device manual, clear photographs, and a known-good sample can also move the project forward. We will organize the details into a manufacturable cable specification your purchasing and maintenance teams can reuse. For adjacent high-density formats, the SCSI cable collection provides a useful visual starting point, but the equipment documentation remains the authority for the interface.

Specifications

ItemAvailable Configuration
ConnectorMDR / Mini Delta Ribbon family
Position count14, 20, 26, 36, 50 or 68
Cable endsMDR-to-MDR, MDR-to-IDC, flying leads, or approved mixed interface
Pin mapStraight, crossed, paired, grouped, or device-specific
ConductorsSize and construction selected for current, flexibility, and termination needs
ShieldingOverall foil, braid, combined shield, drain wire or application-defined design
HardwareLatch, screw or shell arrangement matched to the mating equipment
LengthCustom; branch and breakout dimensions stated separately
MarkingWire numbers, branch labels, customer P/N and lot identification available
InspectionContinuity, open/short, and pin-assignment verification

Learn more about what to consider when buying an MDR cable.

Models and Configuration Options

MDR-to-MDR Cable Assemblies

Each model family can be reviewed for gender, locking hardware, cable exit, wiring, and shield termination.

MDR 14-Pin Cable: Mini Delta Ribbon cable with 14-pin connector for compact SCSI or servo applications.
MDR 14-Pin Cable

P/N: BC-CSC002-14

MDR 20-Pin Cable: Mini Delta Ribbon cable with 20-pin connector for industrial control and data transmission.
MDR 20-Pin Cable

P/N: BC-CSC002-20

MDR 26-Pin Cable: Mini Delta Ribbon cable with 26-pin connector for SCSI and machine vision interfaces.
MDR 26-Pin Cable

P/N: BC-CSC002-26

MDR 36-Pin Cable: Mini Delta Ribbon cable with 36-pin connector for high-density SCSI connections.
MDR 36-Pin Cable

P/N: BC-CSC002-36

MDR 50-Pin Cable: Mini Delta Ribbon cable with 50-pin connector for wide SCSI bus and servo systems.
MDR 50-Pin Cable

P/N: BC-CSC002-50

MDR 68-Pin Cable: Mini Delta Ribbon cable with 68-pin connector for high-speed SCSI and servo drive links.
MDR 68-Pin Cable

P/N: BC-CSC002-68

MDR Flying-Lead Assemblies

Choose an MDR connector at one end and identified conductors or terminals at the other. This format is useful for cabinet wiring and maintenance replacements when you document every wire number and termination point.

MDR 14-Pin Cable with Terminals: Pre-terminated 14-pin MDR cable with crimped terminals for easy field installation.
MDR 14-Pin Cable with Terminals

P/N: BC-CSC002-14-T

MDR 20-Pin Cable with Terminals: Pre-terminated 20-pin MDR cable with crimped terminals for secure connections.
MDR 20-Pin Cable with Terminals

P/N: BC-CSC002-20-T

MDR 26-Pin Cable with Terminals: Pre-terminated 26-pin MDR cable with crimped terminals for reliable signal integrity.
MDR 26-Pin Cable with Terminals

P/N: BC-CSC002-26-T

MDR 36-Pin Cable with Terminals: Pre-terminated 36-pin MDR cable with crimped terminals for industrial use.
MDR 36-Pin Cable with Terminals

P/N: BC-CSC002-36-T

MDR 50-Pin Cable with Terminals: Pre-terminated 50-pin MDR cable with crimped terminals for high-density wiring.
MDR 50-Pin Cable with Terminals

P/N: BC-CSC002-50-T

MDR 68-Pin Cable with Terminals: Pre-terminated 68-pin MDR cable with crimped terminals for complex SCSI setups.
MDR 68-Pin Cable with Terminals

P/N: BC-CSC002-68-T

MDR50-to-IDC50 Assemblies

For servo and industrial control connections, MDR50-to-IDC50 assemblies are available with an approved pin map. IDC keying, strain relief, cable orientation, and pin-1 position must be shown on the drawing.

SCSI Servo Connection Cable: MDR cable designed for servo drive communication in automation and motion control systems.
MDR (CN) 50P to IDC 50P Cable

P/N: BC-CSC002-50-IDC

Give Us the Equipment Context

“MDR50 cable” still leaves several important questions unanswered. A servo controller, camera interface, and test fixture may share the same shell but use different wiring. Sharing the equipment models and functions up front lets us ask useful questions and keeps the quotation tied to your application.

MDR Cable Application: Used in SCSI storage arrays, servo motor drives, CNC machines, and industrial automation systems.
Terminal Installation Guide: Step-by-step illustration for crimping and inserting terminals into MDR connector housing.

Clear Wire Identification Saves Service Time

For flying-lead assemblies, specify numbered sleeves and an end-to-end termination schedule. A technician should be able to replace the cable without tracing fifty conductors inside a live cabinet. We can match labels to your terminal plan and customer part number.

From One Sample to a Repeatable Part

If the only reference is an old cable, we can use it as the starting point and document the result. The goal is not merely to reproduce one piece; it is to create an approved drawing, inspection method, and labeling scheme that support future orders.

Gold-Plated MDR Connector: Corrosion-resistant gold plating on pins ensures stable signal transmission and long service life.
MDR Cable Construction Diagram: Cross-section showing conductor gauge, insulation, shielding layers, and PVC jacket.

That Makes an MDR Quote More Reliable

Send the equipment model at both ends, MDR position count, connector gender, retention method, cable length, and order quantity. Add the pin schedule, signal names, or a manual page whenever they are available. For flying leads, include the terminal type, strip length, conductor IDs, and the point from which each branch is measured.

If your drawing calls for a flat internal connection rather than an MDR shell, compare it with our SCSI Ribbon Cable options. This can help distinguish a true MDR-to-IDC harness from two unrelated cable requirements.

Does an MDR connector identify the communication protocol?

No. MDR is used across several industrial interfaces. Confirm the device models and pin assignments.

Can you make MDR cables with different pin counts at each end?

Potentially, yes, when the wiring and electrical compatibility are documented. A connector adapter is not automatically a signal converter.

Can you supply numbered flying leads?

Yes. Please provide the terminal schedule, wire identification format, stripped length, and terminal requirements.

Can you reproduce a damaged cable?

Often, yes, but a known-good sample or device documentation is safer. Damage can make continuity readings misleading.

Are custom labels and packaging available?

Yes. The production specification can include customer part numbers, end labels, bag labels, and lot information.

What should be checked on a first article?

Check physical mating, retention, cable routing, pin function, branch labels, and operation in the intended equipment.

Do you support repeat OEM orders?

Yes. An approved drawing and revision-controlled specification help keep later lots consistent.

Can several MDR pin counts be ordered together?

Yes, subject to quotation. Give every pin count and length its own part number and quantity so the order and labels cannot be confused.

Can you follow our approved connector brand or BOM?

Yes, when the specified parts are available and suitable for production. State whether substitutes require written approval.

What documentation can accompany an OEM order?

We can discuss drawing revisions, inspection records, and requested compliance documents during the quotation. Availability depends on the selected materials and agreed production plan.

How should a quality issue be reported?

Provide the cable part number, lot information, equipment used, photographs, and a clear description of the observed failure. Keep the affected sample available for evaluation.

How to Recreate an MDR Cable When the Original Drawing Is Missing

Legacy industrial cables often outlive their suppliers and paperwork. When an MDR assembly fails, the maintenance team may have only a worn sample and a machine that cannot remain idle. A disciplined review makes replacement far safer than ordering by appearance.

Identify the Position Count and Mating Hardware

Count the contacts from a clear front view and note whether the plug uses latches, screws, or another retention method. Photograph the equipment port and the cable end together if possible. Shell size alone is an unreliable guide, especially when a factory uses several MDR sizes.

Record the Function of Each End

Write down the controller, drive, camera, interface card, or terminal board connected at each end. Manuals may provide signal names even when they omit a cable part number. Those names help distinguish paired signals, grounds, shields, and unused contacts.

Treat Continuity Data as Evidence, Not the Whole Specification

A meter can show which contacts connect, but a continuity list may not reveal pair construction, shield termination, or conductor grouping. Open the sample only with permission, document the viewing direction, and keep the original available for comparison. If the sample is suspected of being faulty, do not treat every reading as correct.

Define Flying Leads So They Cannot Be Swapped

For terminal ends, specify conductor color, printed number, stripped length, terminal type, and branch length. A table should connect each MDR contact to one clearly identified wire. This makes incoming inspection and field replacement much easier.

Approve a First Article

For a proprietary pinout, a first article gives both sides a practical checkpoint. Confirm mating, cable routing, device operation, and label readability before releasing the full quantity. The approved sample and drawing then become the baseline for repeat production.

If your team has photographs and a working cable but no formal drawing, send what you have. We can help turn scattered information into a controlled specification while clearly marking anything that still needs customer confirmation.

Define Shield Connections Explicitly

The words “shielded cable” do not state where the shield and drain are terminated. Show whether the shield bonds to both connector shells, one end only, a separate terminal, or another point required by the equipment design. This detail matters for inspection and should not be left to shop-floor interpretation.

Decide How Substitutions Will Be Controlled

If the project uses an approved connector manufacturer, terminal brand, or cable construction, state whether alternatives are prohibited or require written approval. For repeat OEM work, a locked bill of materials or an agreed substitution process reduces the chance that a mechanically similar component changes mating, routing, or test results.

Build a Useful Acceptance Package

The appropriate records depend on your project. Some buyers need only the approved drawing and shipment inspection; others request a first-article report, continuity table, material declarations, or sample photographs. Discuss the documentation during quotation so the production and quality plan reflects the actual requirement. You can also review our quality control process before defining project-specific records.

Move From a Pilot Build to Repeat Production

Use the pilot build to confirm connector mating, latch operation, cable routing, wire identification, and device function. Collect all approved changes in the drawing rather than leaving them in email comments or on a marked sample bag. When the pilot is accepted, freeze the drawing revision, label format, and any critical BOM restrictions. Repeat orders can then reference a controlled part instead of restarting the reverse-engineering process.

Organize Mixed-SKU Deliveries

For projects using several MDR contact counts or branch lengths, assign a separate part number to every configuration. The outer carton, inner bag, and cable label should use the same identity. If the cables are delivered as machine kits, provide a packing list that connects each part number to its installation position. This makes receiving, line-side distribution, and spare-part storage much less dependent on visual comparison.

Get an Instant Quote Now
Quick Quote

Get an Instant Quote for Your Latest Project

Scroll to Top