x
Send Your Inquiry Today
Quick Quote
  • 68 Pin SCSI Cable: Standard 68-pin SCSI interface cable for high-speed data transfer between SCSI devices such as disk arrays and tape libraries.
  • HPDB68 SCSI Cable: Half-pitch D-sub 68-pin SCSI cable with compact connector design for high-density SCSI-3 and Ultra320 applications.
  • VHDCI 68 Pin Cable: Very High Density Cable Interconnect 68-pin cable for SCSI connections in servers, RAID systems, and industrial equipment.
  • 68 Pin SCSI Ribbon Cable: Flat ribbon 68-pin SCSI cable with IDC connectors for internal daisy-chain connections between SCSI devices.
  • Internal 68 Pin SCSI Cable: Internal SCSI cable with 68-pin connectors for connecting hard drives and peripherals inside computer chassis.
  • 68 Pin SCSI Connector Dimension Drawing: Mechanical outline, pin spacing, and mounting hole dimensions for HPDB68 and VHDCI 68-pin SCSI connectors.
  • 68 Pin SCSI Cable: Standard 68-pin SCSI interface cable for high-speed data transfer between SCSI devices such as disk arrays and tape libraries.
  • HPDB68 SCSI Cable: Half-pitch D-sub 68-pin SCSI cable with compact connector design for high-density SCSI-3 and Ultra320 applications.
  • VHDCI 68 Pin Cable: Very High Density Cable Interconnect 68-pin cable for SCSI connections in servers, RAID systems, and industrial equipment.
  • 68 Pin SCSI Ribbon Cable: Flat ribbon 68-pin SCSI cable with IDC connectors for internal daisy-chain connections between SCSI devices.
  • Internal 68 Pin SCSI Cable: Internal SCSI cable with 68-pin connectors for connecting hard drives and peripherals inside computer chassis.
  • 68 Pin SCSI Connector Dimension Drawing: Mechanical outline, pin spacing, and mounting hole dimensions for HPDB68 and VHDCI 68-pin SCSI connectors.
P/N: BC-CSC005

Custom 68 pin SCSI cable

  • HPDB68, VHDCI68, and internal 68-position IDC formats
  • External round cable and internal ribbon-harness options
  • Male-to-male, extension, and equipment-specific arrangements
  • SE, LVD, or HVD application recorded before cable approval
  • Retention, hood clearance, and cable-exit review
  • Controlled pin-1 orientation and connector spacing for internal harnesses
  • Custom labels, lengths and OEM packaging
  • Continuity and wiring verification for every assembly

Custom 68 Pin SCSI Cable Assemblies

“68 pin SCSI cable” narrows the search, but it still describes several physically different products. You can’t select an external HPDB68 cable, a compact VHDCI68 cable, or an internal 68-position ribbon harness by contact count alone. Gender, retention, bus type, and pinout all matter.

We manufacture these formats to approved specifications and help you identify which one your system needs. If you are maintaining a legacy array, industrial computer, or test platform, send the equipment models, port photos, and existing cable information. We will organize the details before confirming the construction. Our SCSI cable collection provides a wider family overview when the existing cable name is uncertain.

Specifications

ItemAvailable Configuration
Position count68
External connectorsHPDB68 or VHDCI68
Internal connector68-position IDC/ribbon interface
GenderDefined by both mating ports
RetentionScrews, clips, latches or internal strain relief as applicable
Signal classSE, LVD, HVD, or proprietary-customer/equipment confirmation required
PinoutStandard-compatible or customer-specific approved wiring
LengthSet by installation and complete bus requirements
IdentificationHost/device labels, customer P/N, and pin-1 marking available
InspectionContinuity, short circuit, and wiring orientation checks

Learn more about choosing the 68 Pin SCSI Cable.

Models and Configuration Options

HPDB68 External Cable

  • HPDB68 cable family with hood and retention options.
  • Suitable when the mating ports are confirmed to be HPDB68. Specify gender, screws or clips, hood material, length, and signal class.
68 Pin SCSI Cable: Standard 68-pin SCSI interface cable for high-speed data transfer between SCSI devices such as disk arrays and tape libraries.
68 Pin SCSI Cable

P/N: BC-CSC005-HPDB68-MS

HPDB68 SCSI Cable: Half-pitch D-sub 68-pin SCSI cable with compact connector design for high-density SCSI-3 and Ultra320 applications.
HPDB68 SCSI Cable

P/N: BC-CSC005-HPDB68-PS

VHDCI68 External Cable

  • Compact VHDCI68 cable family.
  • The compact connector requires careful confirmation of gender, screw hardware, adjacent-port clearance, and the second-end interface.
VHDCI 68 Pin Cable: Very High Density Cable Interconnect 68-pin cable for SCSI connections in servers, RAID systems, and industrial equipment.
VHDCI 68 Pin Cable

P/N: BC-CSC005-VHDCI68-MS

HPDB68 Ribbon and Extension Options

  • 68-position ribbon, male-to-male arrangement.
  • 68-position ribbon/extension, male-to-female arrangement.
  • The harness drawing should show connector orientation, keying, spacing, and pin-1 stripe direction.
68 Pin SCSI Ribbon Cable: Flat ribbon 68-pin SCSI cable with IDC connectors for internal daisy-chain connections between SCSI devices.
68 Pin SCSI Ribbon Cable

P/N: BC-CSC005-HPDB68RMM

Internal 68 Pin SCSI Cable: Internal SCSI cable with 68-pin connectors for connecting hard drives and peripherals inside computer chassis.
Internal 68 Pin SCSI Cable

P/N: BC-CSC005-HPDB68RMF

Count the Contacts, Then Identify the Connector Family

The words “68 pin” do not distinguish between HPDB, VHDCI, and IDC. Send one straight-on photo and one side photo of each port. We’ll confirm the mechanical family before discussing cable construction.

Zinc Alloy Housing: Durable zinc alloy connector shell provides superior mechanical strength and EMI shielding for 68-pin SCSI cable.
Multi-Layer Shielding: Tinned copper conductors with twisted pair cores, aluminum foil, and braided mesh shielding for maximum EMI/RFI protection on 68-pin SCSI cable.

Record SE, LVD or HVD

Don’t mix these signaling classes casually. Check the controller and device documentation and include the results in the purchase specification. If the information is unavailable, flag it as unresolved rather than assuming compatibility.

One Drawing for Purchasing, Production and Service

A useful drawing shows connector faces, gender, retention, length reference, pin map, and end labels. It gives purchasing a clear description, production a testable requirement, and service technicians a dependable replacement reference.

All-Copper Gold-Plated Connector: Solid copper contacts with premium gold plating ensure corrosion resistance and stable signal transmission for 68-pin SCSI connections.
68 Pin SCSI Ribbon Connector: IDC style 68-pin ribbon connector for terminating 68-conductor SCSI ribbon cable in high-density applications.

What We Need to Identify Your 68-Pin Cable

Send a straight-on photograph of each equipment port, a side view showing the locking hardware, the device model numbers, and a photograph of the complete existing cable. Confirm whether the connection is external or internal and whether the documentation identifies SE, LVD, or HVD signaling. Add the required length, quantity, and any customer part number.

When the port is a compact 0.8 mm interface, review the VHDCI Cable options. For connections inside a chassis, the SCSI Ribbon Cable page explains the additional spacing and orientation information needed for an internal harness.

Are all 68-pin SCSI connectors the same size?

No. HPDB68, VHDCI68, and IDC68 are different mechanical formats.

Can a VHDCI68 cable replace an HPDB68 cable?

Only with a correctly designed mixed-interface assembly and compatible equipment. The connectors do not mate directly.

Why do you ask whether the system is SE, LVD or HVD?

Identical-looking connectors can be used with electrically different systems. The cable must be specified for the actual bus.

Can you make an internal 68-position ribbon harness with several connectors?

Yes. Provide the connector order, spacing, orientation, keying, and the required termination arrangement.

Can you add host and device labels?

Yes. Directional labels help when the wiring or connector genders aren’t symmetrical.

Do you offer first-article approval?

Custom projects can be planned with sample confirmation before the main lot, subject to the agreed order process.

What photos are most useful?

Send a front view of each port, a side view showing retention and clearance, equipment labels, and the full existing cable.

Can HPDB68 and VHDCI68 versions be quoted together?

Yes. List each connector combination, length, drawing, and quantity as a separate line item.

Can you add directional host and device labels?

Yes. Provide the exact label wording and show its position on the drawing.

How should repeat orders reference an approved cable?

Use the customer or supplier part number together with the latest approved drawing revision. Do not rely only on the equipment nickname.

What documents should be requested with a bulk order?

Request only the records your project needs, such as drawing revisions, inspection results, or relevant material declarations. Confirm availability during the quotation.

How to Build a Complete 68-Pin SCSI Cable Specification

Many wrong-cable orders begin with accurate but incomplete information. “68 pin” may be true, yet it omits the choices that decide whether the assembly can be installed and operated.

Choose HPDB68, VHDCI68 or IDC68

HPDB68 is a half-pitch external connector, VHDCI68 is a more compact high-density interface, and IDC68 is commonly used on internal ribbon assemblies. They belong to different mechanical families. Name the connector at each end rather than using only the contact count.

State Gender From the Mating Face

Shell appearance can be confusing in photographs. Identify whether each cable connector must have pins or sockets and include a mating-face image. For extensions, confirm which end is male and which is female.

Document the Bus Type

SE, LVD, and HVD describe electrical behavior, not simply connector shape. Use labels, manuals, and controller documentation to establish the system type. If several devices share the bus, review the complete chain.

Define Internal Harness Geometry

For ribbon assemblies, list every connector in order, its centerline position, orientation, and pin-1 direction. A correct pinout with one reversed IDC connector is still an unusable harness. Include bend and routing constraints if the assembly fits a compact chassis.

Keep Adapter Cables Honest

A cable with two different connectors changes the mechanical interface; it does not necessarily convert signaling or protocols. Build cross-family assemblies only when the equipment documentation provides a valid wiring relationship.

The most useful request is not the longest. A small package with port photos, equipment models, connector names, bus type, pin map, length, and quantity gives us enough context to respond responsibly and efficiently.

Review Adapter Cables at Both Ends

For HPDB68-to-VHDCI68 assemblies, check more than the cable connectors. Confirm the controller, peripheral, gender, and retaining hardware at each device. Show whether the pin map is straight, reordered, or equipment-specific. If a passive cable cannot provide the required electrical compatibility, changing the connector shell will not solve the system problem.

Define Acceptance Before the First Sample

A first article should mate without force, lock securely, route within the available space, and operate in the intended system. If the cable is directional, confirm the end labels. Record the approved drawing revision and any system-test result that your team uses for acceptance. This creates a much stronger reorder reference than a photograph alone.

Keep Variants Separate in Purchasing Records

HPDB68, VHDCI68, and IDC68 products should not share one vague description in your ERP system. Give each connector combination, length, and pinout a unique part number. If you stock service spares, include the equipment name and revision on the package label. Our quality control process can help your team decide which inspection records to include with production orders.

Use a Configuration Matrix for Multi-Cable Projects

When a machine or storage system uses several 68-position assemblies, create a short matrix with columns for customer part number, connector A, connector B, gender, retention, signaling, length, drawing revision, and quantity. The matrix exposes missing information before quotation and prevents two visually similar cables from being merged into one item. It also gives receiving and maintenance teams a simple index without replacing the detailed drawings.

Separate Mechanical and Electrical Approval

Mechanical approval confirms that the plug mates, locks, and routes correctly. Electrical approval confirms that the cable belongs on that bus and follows the authorized pin map. Both are necessary, especially for HPDB-to-VHDCI designs. Record who approves each part of the specification so a connector change is not mistaken for permission to change signaling or topology.

Get an Instant Quote Now
Quick Quote

Get an Instant Quote for Your Latest Project

Scroll to Top