x
Send Your Inquiry Today
Quick Quote
  • Molex Picoflex 90327 Cable: 1.27mm pitch ribbon cable assembly compatible with Molex Picoflex 90327 series connectors for compact board-to-board and peripheral connections.
  • Molex Picoflex 90327 Connector: Insulation displacement connector from the Molex Picoflex 90327 series with 1.27mm pitch for high-density ribbon cable termination.
  • UL2651 28AWG 1.27mm Ribbon Cable: UL-rated 28 AWG flat ribbon cable with 1.27mm spacing, stranded tinned copper conductors, and PVC insulation for Picoflex termination.
  • Molex Picoflex 90327 Connector Datasheet: Technical specifications including contact rating, insulation resistance, operating temperature, and mechanical dimensions.
  • Molex Picoflex 90327 Cable Application: Used in compact industrial controls, medical devices, test equipment, and consumer electronics requiring high-density signal routing.
  • Molex Picoflex 90327 Cable: 1.27mm pitch ribbon cable assembly compatible with Molex Picoflex 90327 series connectors for compact board-to-board and peripheral connections.
  • Molex Picoflex 90327 Connector: Insulation displacement connector from the Molex Picoflex 90327 series with 1.27mm pitch for high-density ribbon cable termination.
  • UL2651 28AWG 1.27mm Ribbon Cable: UL-rated 28 AWG flat ribbon cable with 1.27mm spacing, stranded tinned copper conductors, and PVC insulation for Picoflex termination.
  • Molex Picoflex 90327 Connector Datasheet: Technical specifications including contact rating, insulation resistance, operating temperature, and mechanical dimensions.
  • Molex Picoflex 90327 Cable Application: Used in compact industrial controls, medical devices, test equipment, and consumer electronics requiring high-density signal routing.
P/N: BC-CAI009

Molex Picoflex 90327 Cable

  • Picoflex 90327 IDT cable receptacle interface
  • 1.27mm nominal mating pitch
  • Low-profile cable-to-board connection
  • Original Molex or approved alternative options
  • Custom assembly length and cable exit
  • Circuit count selected for the mating header

Molex Picoflex 90327 Cable —Low Profile Ribbon Assemblies for Your Equipment

A Picoflex 90327 cable provides a low-profile ribbon connection where board space and cable access need careful planning. BespokeCable supplies custom assemblies for this interface, with the circuit count, length, and routing selected around the equipment rather than a fixed catalog lead.

We can supply original Molex connectors or review a compatible alternative with you. Start with the header and receptacle references, or send photographs of the existing connection. We can help confirm the cable details needed for an accurate quotation.

Specification Table

ItemSpecification
Assembly referenceBC-CAI009 project family
Referenced cable componentMolex Picoflex 90327 IDT receptacle
Nominal family pitch1.27mm
Family circuit range4 to 26; exact availability by full part number
PCB sideSelected compatible Picoflex header; confirm exact reference and retention features
Ribbon constructionGauge, spacing, and insulation selected to the receptacle application specification
Length and exitsCustom dimensions with agreed measurement endpoints
Pin mapDefined by the complete cable and equipment drawing
Materials and platingSelected component specification, including applicable suffixes
Mated envelopeConfirm the actual receptacle and header combination
Electrical limitsReview current, voltage, and temperature for the complete assembly
Supply scopeCable assembly, mating parts, and documentation quoted explicitly
Component sourcingOriginal branded components or separately identified alternatives subject to customer approval

The Receptacle and Header as a Pair

90327 identifies the Picoflex IDT cable receptacle. It is a cable-mounted component, while the compatible header sits on the board. Choosing them as a pair helps establish the installed height and access needed around the connection.

The family includes multiple circuit counts and component variations. We work from the complete references so the proposed cable fits the selected header rather than relying on a general Picoflex description.

Molex Picoflex 90327 Connector: Insulation displacement connector from the Molex Picoflex 90327 series with 1.27mm pitch for high-density ribbon cable termination.
Molex Picoflex 90327 Cable Application: Used in compact industrial controls, medical devices, test equipment, and consumer electronics requiring high-density signal routing.

A Low Profile Route With Room for Service

The connector may fit under a cover but leave too little room to remove the cable. Consider the mated height, nearby components, and the path your hand or service tool will take. These details matter in equipment that will be opened after installation.

Show the first bend and any support point on the route drawing. We can discuss length and exit direction without forcing the ribbon to turn sharply at the receptacle.

A Source Option That Matches Your Purchasing Policy

Choose original Molex parts when your design calls for them. Where alternatives are permitted, we can discuss a separate proposal for evaluation. Include the component identity in the quotation and the approved BOM.

Ribbon gauge and insulation must suit the actual IDT contact. Keeping the connector and wire combination together helps preserve the termination that was approved during sampling.

UL2651 28AWG 1.27mm Ribbon Cable: UL-rated 28 AWG flat ribbon cable with 1.27mm spacing, stranded tinned copper conductors, and PVC insulation for Picoflex termination.
Are matching PCB headers included with the cable?

Only when listed in the quotation. If you need them, provide the header reference and quantity alongside the cable requirement.

Can I request any circuit count from 4 to 26?

The family spans that range, but a particular component is selected by its full part number. Send the required quantity so we can discuss availability and the matching interface.

Can the contact finish change after sample approval?

Treat it as a component change. The proposed finish must suit the mating part and application, and you should approve the change before it appears in production.

Can several circuit counts be packed as a service kit?

Yes, we can discuss kits containing clearly identified assemblies. Use the cable references and quantities for the kit, since similar housings may conceal different wiring or lengths.

Can connector color be specified?

Include the color requirement with the full component reference. Availability depends on the selected part; appearance should not drive an unapproved change to the mating interface.

Developing a Picoflex Cable for a Shallow Enclosure

A low-profile connector is useful when the whole cable route can take advantage of it. For a shallow enclosure, key dimensions often include the cable exit and the space above nearby components, not just the connector height in a catalog.

Look at the Mated Assembly

Place the intended receptacle and board header into the enclosure model or a physical trial. Include any retention features and the external dimensions of the ribbon termination. This gives a more realistic picture than comparing unmated connector heights.

Allow the Cable to Be Installed Without Strain

If the cable has to be connected before a board is secured, the temporary assembly position may need extra reach. If the cover remains attached during servicing, the open-cover position may control the required length. Tell us which operation determines the route so the assembly is not sized only for the closed product.

For continuous movement, describe the motion separately. Low connector height does not establish repeated-flex capability for the ribbon.

Keep the Design Choice Separate From Family Comparisons

A Micro-MaTch ribbon assembly or Milli-Grid assembly may be relevant while choosing a new connector system. Don’t treat either as a Picoflex replacement without changing and qualifying the corresponding interface.

Get a Quote From the Installation Details

Send the endpoint references, circuit count, and an approximate route or finished length. Include any fixed BOM requirements and the quantities you are considering. If access beneath the cover is the difficult part, a photo or section view helps us focus the cable discussion on that constraint.

Once you approve a sample, identify the complete cable by its assembly reference. The 90327 component number alone does not capture the length, other endpoint, or wiring.

Get an Instant Quote Now
Quick Quote

Get an Instant Quote for Your Latest Project

Scroll to Top