  • DB9 to DB25 Null Modem Cable: Cross-wired RS232 serial cable with DB9 and DB25 connectors for direct computer-to-computer communication without a modem.
  • DB9 to DB25 Null Modem Cable Pinout Diagram: Cross-pin wiring mapping showing TxD to RxD, RxD to TxD, RTS to CTS, and ground connections between DB9 and DB25 connectors.
  • DB9 to DB25 Null Modem Cable Application: Used for direct computer-to-computer file transfer, industrial PLC programming, CNC machine communication, and legacy serial device networking via RS232 protocol.
  • DB9 to DB25 Null Modem Cable Datasheet: Technical specifications including cable length options, conductor gauge, shielding type, pinout configuration, RS232 compliance, and operating temperature range.
  • DB9 to DB25 Null Modem Cable Specification: Conductor gauge, insulation material, shielding structure, jacket type, and electrical ratings for cross-wired RS232 null modem cable construction.
  • DB9 to DB25 Null Modem Cable: Cross-wired RS232 serial cable with DB9 and DB25 connectors for direct computer-to-computer communication without a modem.
  • DB9 to DB25 Null Modem Cable Pinout Diagram: Cross-pin wiring mapping showing TxD to RxD, RxD to TxD, RTS to CTS, and ground connections between DB9 and DB25 connectors.
  • DB9 to DB25 Null Modem Cable Application: Used for direct computer-to-computer file transfer, industrial PLC programming, CNC machine communication, and legacy serial device networking via RS232 protocol.
  • DB9 to DB25 Null Modem Cable Datasheet: Technical specifications including cable length options, conductor gauge, shielding type, pinout configuration, RS232 compliance, and operating temperature range.
  • DB9 to DB25 Null Modem Cable Specification: Conductor gauge, insulation material, shielding structure, jacket type, and electrical ratings for cross-wired RS232 null modem cable construction.
P/N: BC-CBD-008

DB9 to DB25 Null Modem Cable

  • Passive DB9-to-DB25 null-modem assembly for documented DTE-to-DTE links
  • Crossed TxD/RxD with project-defined signal-ground connection
  • Three-wire, full-handshake, or equipment-specific control-line mapping
  • Molded or assembled hood construction by quotation
  • Custom cable length, shielding, labels, packaging, and retention
  • No driver required for the passive cable itself
  • Continuity and short-circuit inspection to the approved crossover map

Custom DB9 to DB25 Null Modem Cable for DTE-to-DTE RS-232 Links

A DB9 to DB25 null modem cable connects two compatible RS-232 devices that both behave as DTE without placing a modem between them. It crosses the transmit and receive functions and, when required by the equipment, crosses or loops hardware-handshake circuits.

“Null modem” is not one universal pinout. A three-wire link and a full-handshake link can use the same connector genders while having different internal wiring. BespokeCable builds this assembly from the manuals, an approved connection table, or a verified working sample rather than relying on a generic crossover diagram.

If you don’t need an RS-232 crossover, use the D-Sub cable collection to identify the right connector family before specifying the map.

DB9 to DB25 Null Modem Cable Specifications

ParameterAvailable ChoicesConfirmation Needed
Product rolePassive DTE-to-DTE RS-232 crossoverBoth device roles and manuals
Connector ADB9, Female in the listed configurationActual mating port
Connector BDB25, Male in the listed configurationActual mating port
Data mappingTxD crossed to RxDApproved contact numbers
HandshakeNone, crossed, or locally loopedFlow-control requirement
GroundDevice-defined signal groundDB9/DB25 ground contacts
ShieldProject-definedShell/drain bond and grounding plan
LengthStandard or customBaud rate, route, datum, tolerance
IdentificationNull-modem ID, end labels, customer P/NExact wording and placement
VerificationContinuity and shorts to released drawingReport or first-article needs

The approved quotation and drawing define final wiring, materials, dimensions, electrical limits, and compliance requirements.

Click here to learn more about a DB9 to DB25 Null Modem Cable. 

Use a Crossover for Compatible DTE Endpoints

A DB9-to-DB25 null modem cable is intended for compatible RS-232 endpoints that require a crossover between their transmit and receive functions. It is a wiring arrangement, not an active converter. Connector genders do not prove that both devices have the necessary roles.

Check the interface description in each equipment manual. If the connection is between DTE and DCE and calls for corresponding signals to be preserved, review the DB9-to-DB25 serial cable instead of assuming a null modem is always the safer choice.

DB9 to DB25 Null Modem Cable Specification: Conductor gauge, insulation material, shielding structure, jacket type, and electrical ratings for cross-wired RS232 null modem cable construction.
DB9 to DB25 Null Modem Cable Datasheet: Technical specifications including cable length options, conductor gauge, shielding type, pinout configuration, RS232 compliance, and operating temperature range.

Choose the Required Handshake Arrangement

A basic transmit, receive, and signal-ground connection can serve equipment configured to operate without hardware flow control. Other devices require control lines to cross between endpoints or to be locally looped in a particular way. These alternatives are not one interchangeable “full handshake” map.

Provide the required signals and exact connections for each end. Document every local loop separately from the end-to-end conductors. This lets the cable drawing show the intended behavior clearly and prevents an apparently complete nine-to-twenty-five-pin assembly from omitting a control path that the application needs.

Match Length and Construction to the Service Route

RS-232 performance depends on the endpoints, settings, and installed cable, so you can’t determine the useful length from “null modem” alone. Describe the route, intended baud rate, and noise environment when requesting a quotation.

For a lead handled by maintenance staff, review grip space and strain relief. For a fixed cabinet connection, review support and the shield termination plan. A long passive crossover is not a substitute for a system-level solution where distance or grounding conditions exceed what the equipment can support.

DB9 to DB25 Null Modem Cable Application: Used for direct computer-to-computer file transfer, industrial PLC programming, CNC machine communication, and legacy serial device networking via RS232 protocol.
DB9 to DB25 Null Modem Cable Pinout Diagram: Cross-pin wiring mapping showing TxD to RxD, RxD to TxD, RTS to CTS, and ground connections between DB9 and DB25 connectors.

Keep the Cable Identity Clear During Maintenance

Straight serial and null-modem cables can use the same external connector combination. Label the assembly so a technician does not replace a working crossover with a visually similar straight transition. Equipment-end identification is especially helpful where several service leads share a kit.

Use the approved part number and wiring revision on the replacement record. These cables can support appropriate CNC, instrument, and legacy-computer links, but suitability depends on the documented equipment connection, not on every device in those categories.

What should I send with a null-modem cable RFQ?

Provide both equipment models, manuals or signal tables, DB9/DB25 gender, serial settings, flow-control mode, length/tolerance, quantity, hood, shielding, label text, and inspection-document needs.

Can you copy a proven CNC or instrument cable?

Yes, when a known-good sample or verified point-to-point table is available. Identify the machine model and revision so that an accidental fault in the sample is not treated as an intentional connection.

What test report can be supplied?

Document continuity and short-circuit results against the approved crossover map. Define the required format and traceability before ordering.

Can a different connector gender be made?

Potentially, yes. Provide the actual mating ports and available clearance. A gender change doesn’t change the need for a verified null-modem map.

Commissioning a DB9 to DB25 Null Modem Link

Establish a common starting configuration

Record baud rate, data bits, parity, stop bits, and flow-control mode at both endpoints before testing. Correct wiring cannot reconcile incompatible settings. Keep a copy of the original values so a troubleshooting change can be reversed without guessing.

For a new link, confirm the intended direction of each data and control signal against the equipment documents. For a replacement, establish whether the old assembly was known to work or was merely found with the machine.

Test communication beyond an initial response

Begin with a controlled transfer using the intended application. Check both directions if the process uses them. Then test a representative workload that exercises the selected flow control. A short exchange may complete even when a longer transfer exposes an unhandled control-line requirement.

When a fault occurs, record whether it is a missing response, corrupted data, or a stalled transfer. Keep settings constant while checking the cable map. Changing wiring and software configuration together makes the result harder to interpret.

Define what sample approval covers

Document the tested machine revisions and application settings alongside the cable drawing. Electrical inspection confirms the cable matches the drawing; commissioning confirms the combination works in its intended setting.

If only one machine type was evaluated, do not treat acceptance as approval for every similar-looking port in the workshop. Review the documents for the next machine and confirm whether it can share the same released cable configuration.

Get an Instant Quote Now